Regenerative Peripheral Nerve Interface Viability and Signal Transduction with an Implanted Electrode
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The regenerative peripheral nerve interface is an internal interface for signal transduction with external electronics of prosthetic limbs; it consists of an electrode and a unit of free muscle that is neurotized by a transected residual peripheral nerve. Adding a conductive polymer coating on electrodes improves electrode conductivity. This study examines regenerative peripheral nerve interface tissue viability and signal fidelity in the presence of an implanted electrode coated or uncoated with a conductive polymer. METHODS: In a rat model, the extensor digitorum longus muscle was moved as a nonvascularized free tissue transfer and neurotized by the divided peroneal nerve. Either a stainless steel pad electrode (n = 8) or a pad electrode coated with poly(3,4-ethylenedioxythiophene) conductive polymer (PEDOT) (n = 8) was implanted on the muscle transfer and secured with an encircling acellular extracellular matrix. The contralateral muscle served as the control. RESULTS: The free muscle transfers were successfully revascularized and over time reinnervated as evidenced by serial insertional needle electromyography. Compound muscle action potentials were successfully transduced through the regenerative peripheral nerve interface. The conductive polymer coating on the implanted electrode resulted in increased recorded signal amplitude that was observed throughout the course of the study. Histologic examination confirmed axonal sprouting, elongation, and synaptogenesis within regenerative peripheral nerve interface regardless of electrode type. CONCLUSIONS: The regenerative peripheral nerve interface remains viable over seven months in the presence of an implanted electrode. Electrodes with and without conductive polymer reliably transduced signals from the regenerative peripheral nerve interface. Electrodes with a conductive polymer coating resulted in recording more of the regenerative peripheral nerve interface signal.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This process creates a stable, peripheral nerve bioamplifier that produces high-amplitude EMG signals, which could be used to control a prosthetic device (14–17).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [17]
In the citing paper
“results from previous animal work, which demonstrated that it took approximately 3 months for RPNIs to mature and stabilize (12, 15–17).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [17]
In the citing paper
“When combined with epimysial electrodes, this mechanism showed good signal transduction and viability for seven months [42].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [42]
In the citing paper
“Also they demonstrated the 7-month viability of the RPNI.”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Kung et al. (2014)
In the citing paper
“In chronic studies in rats, the muscle is reinnervated by the peripheral nerve, and the formation of new neuromuscular junctions is evident.62”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [62]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Techniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,629
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Cosnier, S. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00024-x · Cited by 768
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691
Upper-Limb Prosthetics: Critical Factors in Device Abandonment
Biddiss, E., & Chau, T. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e3181587f6c · Cited by 645
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Self-citationSurface modification of neural recording electrodes with conducting polymer/biomolecule blends
Cui, X., Lee, V. A., Raphael, Y., Wiler, J. A., Hetke, J. F., Anderson, D. J., & Martin, D. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200108)56:2<261::aid-jbm1094>3.0.co;2-i · Cited by 530
Richardson-Burns, S. M., Hendricks, J. L., Foster, B., Povlich, L. K., Kim, D.-H., & Martin, D. C. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.026 · Cited by 503
Self-citationLuo, S.-C., Mohamed Ali, E., Tansil, N. C., Yu, H.-H., Gao, S., Kantchev, E. A. B., & Ying, J. Y. (2008) · Langmuir · doi:10.1021/la800333g · Cited by 323
Ludwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/014001 · Cited by 283
Self-citationPoly (3,4-Ethylenedioxythiophene) for Chronic Neural Stimulation
Cui, X. T., & Zhou, D. D. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.909811 · Cited by 277
Ortiz-Catalan, M., Brånemark, R., & Håkansson, B. (2013) · Source Code for Biology and Medicine · doi:10.1186/1751-0473-8-11 · Cited by 232
Schultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186
The denervated muscle: facts and hypotheses. A historical review
Midrio, M. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0256-z · Cited by 179
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
The Recent Understanding of the Neurotrophin’s Role in Skeletal Muscle Adaptation
Sakuma, K., & Yamaguchi, A. (2011) · BioMed Research International · doi:10.1155/2011/201696 · Cited by 120
Electrochemical polymerization and properties of PEDOT/S-EDOT on neural microelectrode arrays
Xiao, Y., Cui, X. T., & Martin, D. C. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2004.06.024 · Cited by 112
Self-citationCellular responses to free grafting of the extensor digitorum longus muscle of the rat
Hansen‐Smith, F. M., & Carlson, B. M. (1979) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(79)90035-2 · Cited by 99
In Situ Polymerization of a Conductive Polymer in Acellular Muscle Tissue Constructs
Peramo, A., Urbanchek, M. G., Spanninga, S. A., Povlich, L. K., Cederna, P. S., & Martin, D. C. (2008) · Tissue Engineering Part A · doi:10.1089/tea.2007.0123 · Cited by 87
Self-citationThe role of neurotrophins in muscle under physiological and pathological conditions
Chevrel, G., Hohlfeld, R., & Sendtner, M. (2006) · Muscle & Nerve · doi:10.1002/mus.20444 · Cited by 82
Innovations in Prosthetic Interfaces for the Upper Extremity
Kung, T. A., Bueno, R. A., Alkhalefah, G. K., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S. (2013) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3182a97e5f · Cited by 71
Self-citationContractile properties of transplanted extensor digitorum longus muscles of cats
Faulkner, J. A., Niemeyer, J. H., Maxwell, L. C., & White, T. P. (1980) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1980.238.3.c120 · Cited by 52
Zhang, F., Lineaweaver, W. C., Üstüner, T. E., Kao, S. D., Tonken, H. P., Campagna‐Pinto, D., & Buncke, H. J. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199703000-00029 · Cited by 49
Needle Electromyography: Basic Concepts and Patterns of Abnormalities
Rubin, D. I. (2011) · Neurologic Clinics · doi:10.1016/j.ncl.2011.12.009 · Cited by 46
Regeneration of soleus muscles of rat autografted in toto as studied by electron microscopy
Schmalbruch, H. (1977) · Cell and Tissue Research · doi:10.1007/bf00221079 · Cited by 46
Long-Term Stability of Regenerative Peripheral Nerve Interfaces (RPNI)
Urbanchek, M. G., Wei, B., Baghmanli, Z., Sugg, K., & Cederna, P. S. (2011) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000406317.25436.00 · Cited by 30
Self-citationThe free autografting of entire limb muscles in the cat: Morphology
Mufti, S. A., Carlson, B. M., Maxwell, L. C., & Faulkner, J. A. (1977) · The Anatomical Record · doi:10.1002/ar.1091880403 · Cited by 28
Reinnervation of rat extensor digitorum longus muscles after free grafting
Carlson, B. M., Wagner, K. R., & Max, S. R. (1979) · Muscle & Nerve · doi:10.1002/mus.880020411 · Cited by 27
Egeland, B. M., Urbanchek, M. G., Peramo, A., Richardson-Burns, S. M., Martin, D. C., Kipke, D. R., Kuzon, W. M., & Cederna, P. S. (2010) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0b013e3181f61848 · Cited by 23
Self-citationQuantification of Regenerative Peripheral Nerve Interface Signal Transmission
Urbanchek, M. G., Baghmanli, Z., Moon, J. D., Sugg, K. B., Langhals, N. B., & Cederna, P. S. (2012) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000421762.53265.54 · Cited by 21
Self-citationA Review of Free Muscle Grafting
Cedars, M. G., & Miller, T. A. (1984) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198411000-00024 · Cited by 17
155: LONG TERM STABILITY OF REGENERATIVE PERIPHERAL NERVE INTERFACES (RPNI)
Urbanchek, M., Baghmanli, Z., Wei, B., Egeland, B., & Cederna, P. (2011) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000396842.82868.44 · Cited by 11
Self-citationBaldwin, J., Moon, J., Cederna, P., & Urbanchek, M. (2012) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000416183.37499.89 · Cited by 7
Self-citationUrbanchek, M., Moon, J., Sugg, K., Langhals, N. B., Cederna, P., & Baghmanli, Z. (2012) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000416200.27883.3c · Cited by 6
Self-citation
Cited by
Ortiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291
Self-citationProprioception from a neurally controlled lower-extremity prosthesis
Clites, T. R., Carty, M. J., Ullauri, J. B., Carney, M. E., Mooney, L. M., Duval, J.-F., Srinivasan, S. S., & Herr, H. M. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aap8373 · Cited by 233
Woo, S. L., Kung, T. A., Brown, D. L., Leonard, J. A., Kelly, B. M., & Cederna, P. S. (2016) · Plastic and Reconstructive Surgery - Global Open · doi:10.1097/gox.0000000000001038 · Cited by 230
Self-citation
Metadata
- Authors
- Kung, T. A., Langhals, N. B., Martin, D. C., Johnson, P. J., Cederna, P. S., & Urbanchek, M. G.
- Affiliations
- Washington University in St. Louis (US)
- ORCID
- Venue
- Plastic & Reconstructive Surgery
- Published
- 2014-06
- Volume
- 133
- Issue
- 6
- Pages
- 1380-1394
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2330454837
- Cited by
- 181
- References
- 34
- Citations by year
- 2026: 16 · 2025: 14 · 2024: 20 · 2023: 16 · 2022: 25 · 2021: 18 · 2020: 19 · 2019: 10 · 2018: 9 · 2017: 14 · 2016: 8 · 2015: 7 · 2014: 5
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Plastic & Reconstructive Surgery (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Defense Advanced Research Projects Agency
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Keywords
- regenerative peripheral nerve interface, conducting polymer coatings, PEDOT, signal transduction, prosthetic control, free muscle transfer, revascularization, reinnervation, axonal sprouting, synaptogenesis, compound muscle action potential, needle electromyography, rat model
- MeSH terms
- Animals, Artificial Limbs, Electrodes, Implanted, Electromyography, Male, Polymers, Rats, Inbred F344, Regeneration, Signal Transduction, Nerve Transfer, Muscle, Skeletal, Bridged Bicyclo Compounds, Heterocyclic, Coated Materials, Biocompatible, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.