CoChat

Anxiety and Risk of Ventricular Arrhythmias or Mortality in Patients With an Implantable Cardioverter Defibrillator

Open access
HabiboviĆ, Mirela, Pedersen, Susanne S., van den Broek, Krista C., Theuns, Dominic A.M.J., Jordaens, Luc, van der Voort, Pepijn H., Alings, Marco, Denollet, Johan · 2013 · Psychosomatic Medicine
Cited by 58

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences anxiety after device implantation. The purpose of the present study was to evaluate whether anxiety is predictive of ventricular arrhythmias and all-cause mortality 1 year post ICD implantation. METHODS: A total of 1012 patients completed the state version of the State-Trait Anxiety Inventory at baseline. The end points were ventricular arrhythmias and mortality the first year after ICD implantation. RESULTS: Within the first year after ICD implantation, 19% of patients experienced a ventricular arrhythmia, and 4% died. Anxiety was associated with an increased risk of ventricular arrhythmias (hazard ratio [HR] = 1.017; 95% confidence interval [CI] = 1.005-1.028; p = .005) and mortality (HR = 1.038; 95% CI = 1.014-1.063; p = .002) in adjusted analysis. Patients with anxiety (highest tertile) had a 1.9 increased risk for ventricular arrhythmias (95% CI = 1.329-2.753; p =.001) and a 2.9 increased risk for mortality (95% CI = 1.269-6.677; p = .01) compared with patients with low anxiety (lowest tertile). Among 257 patients with cardiac resynchronization therapy, anxiety was associated with mortality (HR = 5.381; 95% CI = 1.254-23.092; p = .02) after adjusting for demographic and clinical covariates. CONCLUSIONS: Anxiety was associated with an increased risk of ventricular arrhythmias and mortality 1 year after ICD implantation, independent of demographic and clinical covariates. Monitoring and treatment of anxiety may be warranted in a selected subgroup of high-risk patients with an ICD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/psy.0b013e3182769426

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 25

  1. Ezekowitz, 2003, Implantable cardioverter defibrillators in primary and secondary prevention: a systematic review of randomized, controlled trials., Ann Intern Med, 138, 445, 10.7326/0003-4819-138-6-200303180-00007 · DOI · Paper page
  2. Zipes, 2006, ACCAHAESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: a report of the American College of CardiologyAmerican Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Develop Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death)., J Am Coll Cardiol, 48, 247, 10.1016/j.jacc.2006.07.010 · DOI · Paper page
  3. Anderson, 2005, Sudden cardiac death unresponsive to implantable defibrillator therapy: an urgent target for clinicians, industry and government., J Interv Card Electrophysiol, 14, 71, 10.1007/s10840-005-4547-9 · DOI
  4. Passman, 2007, Implantable cardioverter defibrillators and quality of life: results from the defibrillators in nonischemic cardiomyopathy treatment evaluation study., Arch Intern Med, 167, 2226, 10.1001/archinte.167.20.2226 · DOI · Paper page
  5. Daubert, 2008, Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact., J Am Coll Cardiol, 51, 1357, 10.1016/j.jacc.2007.09.073 · DOI · Paper page
  6. Poole, 2008, Prognostic importance of defibrillator shocks in patients with heart failure., N Engl J Med, 359, 1009, 10.1056/NEJMoa071098 · DOI · Paper page
  7. Dunbar, 1999, Association of mood disturbance and arrhythmia events in patients after cardioverter defibrillator implantation., Depress Anxiety, 9, 163, 10.1002/(SICI)1520-6394(1999)9:4<163::AID-DA3>3.0.CO;2-B · DOI · Paper page
  8. Pedersen, 2010, Pre-implantation implantable cardioverter defibrillator concerns and Type D personality increase the risk of mortality in patients with an implantable cardioverter defibrillator., Europace, 12, 1446, 10.1093/europace/euq296 · DOI · Paper page
  9. Whang, 2005, Depression as a predictor for appropriate shocks among patients with implantable cardioverter-defibrillators: results from the Triggers of Ventricular Arrhythmias (TOVA) study., J Am Coll Cardiol, 45, 1090, 10.1016/j.jacc.2004.12.053 · DOI · Paper page
  10. Burg, 2004, Psychological traits and emotion-triggering of ICD shock-terminated arrhythmias., Psychosom Med, 66, 898, 10.1097/01.psy.0000145822.15967.15 · DOI · Paper page
  11. Fries, 2002, Triggering effect of physical and mental stress on spontaneous ventricular tachyarrhythmias in patients with implantable cardioverter-defibrillators., Clin Cardiol, 25, 474, 10.1002/clc.4960251007 · DOI · Paper page
  12. Kamphuis, 2003, Implantable cardioverter defibrillator recipients: quality of life in recipients with and without ICD shock deliverya prospective study., Europace, 5, 381, 10.1016/S1099-5129(03)00078-3 · DOI · Paper page
  13. Habibovic, 2011, Posttraumatic stress 18 months following cardioverter defibrillator implantation: shocks, anxiety, and personality., Health Psychol, 31, 186, 10.1037/a0024701 · DOI · Paper page
  14. Roest, 2010, Anxiety and risk of incident coronary heart disease: a meta-analysis., J Am Coll Cardiol, 56, 38, 10.1016/j.jacc.2010.03.034 · DOI · Paper page
  15. Lombardi, 2000, Heart rate variability patterns before ventricular tachycardia onset in patients with an implantable cardioverter defibrillator. Participating Investigators of ICD-HRV Italian Study Group., Am J Cardiol, 86, 959, 10.1016/S0002-9149(00)01130-9 · DOI
  16. Francis, 2009, Association between symptoms of depression and anxiety with heart rate variability in patients with implantable cardioverter defibrillators., Psychosom Med, 71, 821, 10.1097/PSY.0b013e3181b39aa1 · DOI · Paper page
  17. Piccirillo, 2001, Influence of age, the autonomic nervous system and anxiety on QT-interval variability., Clin Sci (Lond), 101, 429, 10.1042/cs1010429 · DOI
  18. Ziegelstein, 2010, Depression and poor adherence to lipid-lowering medications among patients with coronary artery disease., J Psychosom Res, 69, 175, 10.1016/j.jpsychores.2010.04.012 · DOI
  19. Pedersen, 2011, Heart and mind: are we closer to disentangling the relationship between emotions and poor prognosis in heart disease Eur Heart, J, 32, 2341
  20. Dougherty, 2004, Description of a nursing intervention program after an implantable cardioverter defibrillator., Heart Lung, 33, 183, 10.1016/j.hrtlng.2004.01.003 · doi:10.1016/j.hrtlng.2004.01.003
  21. Fitchet, 2003, Comprehensive cardiac rehabilitation programme for implantable cardioverter-defibrillator patients: a randomised controlled trial., Heart, 89, 155, 10.1136/heart.89.2.155 · DOI · Paper page
  22. Salmoirago-Blotcher, 2009, Methodological limitations of psychosocial interventions in patients with an implantable cardioverter-defibrillator (ICD): a systematic review., BMC Cardiovasc Disord, 9, 9, 10.1186/1471-2261-9-56 · DOI · Paper page
  23. Pedersen, 2007, Psychological intervention following implantation of an implantable defibrillator: a review and future recommendations., Pacing Clin Electrophysiol, 30, 1546, 10.1111/j.1540-8159.2007.00905.x · DOI · Paper page
  24. Crossmann, 2010, A randomized controlled trial of secondary prevention of anxiety and distress in a German sample of patients with an implantable cardioverter defibrillator., Psychosom Med, 72, 434, 10.1097/PSY.0b013e3181d9bcec · DOI · Paper page
  25. Dunbar, 2009, Effects of a psychoeducational intervention on depression, anxiety, and health resource use in implantable cardioverter defibrillator patients., Pacing Clin Electrophysiol, 32, 12, 10.1111/j.1540-8159.2009.02495.x · DOI · Paper page

Cited by

See all 58

Metadata

Authors
HabiboviĆ, M., Pedersen, S. S., van den Broek, K. C., Theuns, D. A. M. J., Jordaens, L., van der Voort, P. H., Alings, M., & Denollet, J.
Venue
Psychosomatic Medicine
Published
2013-01
Volume
75
Issue
1
Pages
36-41
ISSN
0033-3174 (ISSN-L)
OpenAlex
W2147599964
Cited by
58
References
6
FWCI
2.88
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.