Microstructural Characterization of Normal and Malignant Human Prostate Tissue With Vascular, Extracellular, and Restricted Diffusion for Cytometry in Tumours Magnetic Resonance Imaging
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The aim of this study was to demonstrate the feasibility of the recently introduced Vascular, Extracellular, and Restricted Diffusion for Cytometry in Tumours (VERDICT) framework for imaging prostate cancer with diffusion-weighted magnetic resonance imaging (DW-MRI) within a clinical setting. MATERIALS AND METHODS: The VERDICT framework is a noninvasive microstructure imaging technique that combines an in-depth diffusion MRI acquisition with a mathematical model to estimate and map microstructural tissue parameters such as cell size and density and vascular perfusion. In total, 8 patients underwent 3-T MRI using 9 different b values (100-3000 s/mm). All patients were imaged before undergoing biopsy. Experiments with VERDICT analyzed DW-MRI data from patients with histologically confirmed prostate cancer in areas of cancerous and benign peripheral zone tissue. For comparison, we also fitted commonly used diffusion models such as the apparent diffusion coefficient (ADC), the intravoxel incoherent motion (IVIM), and the kurtosis model. We also investigated correlations of ADC and kurtosis with VERDICT parameters to gain some biophysical insight into the various parameter values. RESULTS: Eight patients had prostate cancer in the peripheral zone, with Gleason score 3 + 3 (n = 1), 3 + 4 (n = 6), and 4 + 3 (n = 1). The VERDICT model identified a significant increase in the intracellular and vascular volume fraction estimates in cancerous compared with benign peripheral zone, as well as a significant decrease in the volume of the extracellular-extravascular space (EES) (P = 0.05). This is in agreement with manual segmentation of the biopsies for prostate tissue component analysis, which found proliferation of epithelium, loss of surrounding stroma, and an increase in vasculature. The standard ADC and kurtosis parameters were also significantly different (P = 0.05) between tissue types. There was no significant difference in any of the IVIM parameters (P = 0.11 to 0.29). The VERDICT parametric maps from voxel-by-voxel fitting clearly differentiated cancer from benign regions. Kurtosis and ADC parameters correlated most strongly with VERDICT's intracellular volume fraction but also moderately with the EES and vascular fractions. CONCLUSIONS: The VERDICT model distinguished tumor from benign areas, while revealing differences in microstructure descriptors such as cellular, vascular, and EES fractions. The parameters of ADC and kurtosis models also discriminated between cancer and benign regions. However, VERDICT provides more specific information that disentangles the various microstructural features underlying the changes in ADC and kurtosis. These results highlight the clinical potential of the VERDICT framework and motivate the construction of a shorter, clinically viable imaging protocol to enable larger trials leading to widespread translation of the method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Bray, F., Center, M. M., Ferlay, J., Ward, E., & Forman, D. (2011) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20107 · Cited by 54,679 · cited 1×
“P rostate cancer is the most common cancer among men in all economically developed countries.(1) The standard procedure to provide a diagnosis of the disease is transrectal prostate biopsy, which is invasive with possible unpleasant adverse effects(2) and is prone to error.”
BackgroundHoffmann, T. C., Glasziou, P. P., Boutron, I., Milne, R., Perera, R., Moher, D., Altman, D. G., Barbour, V., Macdonald, H., Johnston, M., et al. (2014) · BMJ · doi:10.1136/bmj.g1687 · Cited by 10,548
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169 · cited 1×
“Intravoxel incoherent motion characterizes water dispersion as a combination of a slow component associated with Brownian motion and a fast component associated with the bulk motion of molecules inside microcapillaries.(14,15) It has been used to study various cancer types such as breast,(16) prostate,(9) and pancreat…”
BackgroundJensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488
ESUR prostate MR guidelines 2012
Barentsz, J. O., Richenberg, J., Clements, R., Choyke, P., Verma, S., Villeirs, G., Rouviere, O., Logager, V., & Fütterer, J. J. (2012) · European Radiology · doi:10.1007/s00330-011-2377-y · Cited by 2,438
Intravoxel Incoherent Motion in Body Diffusion-Weighted MRI: Reality and Challenges
Koh, D.-M., Collins, D. J., & Orton, M. R. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5515 · Cited by 527
Norberg, M., Egevad, L., Holmberg, L., Sparén, P., Norlén, B. J., & Busch, C. (1997) · Urology · doi:10.1016/s0090-4295(97)00306-3 · Cited by 423
Compartment models of the diffusion MR signal in brain white matter: A taxonomy and comparison
Panagiotaki, E., Schneider, T., Siow, B., Hall, M. G., Lythgoe, M. F., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.081 · Cited by 422
Self-citationSelf-Diffusion Coefficient of Liquid Lithium
Murday, J. S., & Cotts, R. M. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1668160 · Cited by 365
Alexander, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21646 · Cited by 331 · cited 2×
“Thus, the next step is to design a clinical acquisition protocol using, for example, the experiment design optimization in Alexander.39 Such optimization reduces scan time by producing the minimum optimal combination of b values for estimating the VERDICT parameters.”
MethodSelf-citationComparison of microscopic vascularity in benign and malignant prostate tissue
Bigler, S. A., Deering, R. E., & Brawer, M. K. (1993) · Human Pathology · doi:10.1016/0046-8177(93)90304-y · Cited by 323 · cited 2×
“These results are in agreement with histological assessment of increased cellularity and vascularity within our patient cohort and with existing knowledge of prostate cancer.(13,35) Also, the EES volume fraction was significantly lower for the tumor ROI than the benign region.”
BackgroundResultSato, C., Naganawa, S., Nakamura, T., Kumada, H., Miura, S., Takizawa, O., & Ishigaki, T. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20251 · Cited by 323 · cited 1×
“Most DW-MRI studies have used the technique in its simplest form by calculating the apparent diffusion coefficient (ADC) to identify clinically significant tumor foci more clearly.(5,6) In general, ADC values are lower in prostate carcinoma compared with healthy tissue and are believed to reflect the highly cellular e…”
MethodDynamic Contrast-Enhanced MRI of Prostate Cancer at 3 T: A Study of Pharmacokinetic Parameters
Ocak, İ., Bernardo, M., Metzger, G. J., Barrett, T., Pinto, P. A., Albert, P. S., & Choyke, P. L. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1329 · Cited by 296
Noninvasive Quantification of Solid Tumor Microstructure Using VERDICT MRI
Panagiotaki, E., Walker-Samuel, S., Siow, B., Johnson, S. P., Rajkumar, V., Pedley, R. B., Lythgoe, M. F., & Alexander, D. C. (2014) · Cancer Research · doi:10.1158/0008-5472.can-13-2511 · Cited by 251 · cited 3×
“The biexponential model has also been shown elsewhere in literature to have a variable performance.(20,23,37) The parametric maps from voxel-by-voxel fitting in Figure 7 reflect the trends seen in the whole-ROI fitting in Figure 4.”
BackgroundMethodSelf-citationRosenkrantz, A. B., Sigmund, E. E., Johnson, G., Babb, J. S., Mussi, T. C., Melamed, J., Taneja, S. S., Lee, V. S., & Jensen, J. H. (2012) · Radiology · doi:10.1148/radiol.12112290 · Cited by 241 · cited 4×
“Intravoxel incoherent motion characterizes water dispersion as a combination of a slow component associated with Brownian motion and a fast component associated with the bulk motion of molecules inside microcapillaries.14,15 It has been used to study various cancer types such as breast,16 prostate,9 and pancreatic17,1…”
BackgroundInfluentialSigmund, E. E., Cho, G. Y., Kim, S., Finn, M., Moccaldi, M., Jensen, J. H., Sodickson, D. K., Goldberg, J. D., Formenti, S., & Moy, L. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22740 · Cited by 224
Jespersen, S. N., Lundell, H., Sønderby, C. K., & Dyrby, T. B. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2999 · Cited by 197
Pang, Y., Turkbey, B., Bernardo, M., Kruecker, J., Kadoury, S., Merino, M. J., Wood, B. J., Pinto, P. A., & Choyke, P. L. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24277 · Cited by 189
Noninvasive mapping of water diffusional exchange in the human brain using filter‐exchange imaging
Nilsson, M., Lätt, J., van Westen, D., Brockstedt, S., Lasič, S., Ståhlberg, F., & Topgaard, D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24395 · Cited by 188 · cited 1×
“For example, oscillating gradient DW-MRI could give access to subcellular structures such as the nuclei,(38,41,42) whereas double pulsed-field gradient waveform sequences could inform about the shape(43) and permeability of cells.(44)”
BackgroundCharacterization of tissue structure at varying length scales using temporal diffusion spectroscopy
Gore, J. C., Xu, J., Colvin, D. C., Yankeelov, T. E., Parsons, E. C., & Does, M. D. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1531 · Cited by 173
van As, N. J., de Souza, N. M., Riches, S. F., Morgan, V. A., Sohaib, S. A., Dearnaley, D. P., & Parker, C. C. (2009) · European Urology · doi:10.1016/j.eururo.2008.11.051 · Cited by 169
Klau, M., Lemke, A., Grünberg, K., Simon, D., Re, T. J., Wente, M. N., Laun, F. B., Kauczor, H., Delorme, S., Grenacher, L., et al. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181fb3bf2 · Cited by 142
Orton, M. R., Collins, D. J., Koh, D., & Leach, M. O. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24649 · Cited by 135 · cited 1×
“The biexponential model has also been shown elsewhere in literature to have a variable performance.(20,23,37) The parametric maps from voxel-by-voxel fitting in Figure 7 reflect the trends seen in the whole-ROI fitting in Figure 4.”
MethodRiches, S. F., Hawtin, K. E., Charles-Edwards, E., & de Souza, N. M. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1328 · Cited by 128
Investigation of prostate cancer using diffusion-weighted intravoxel incoherent motion imaging
Döpfert, J., Lemke, A., Weidner, A., & Schad, L. R. (2011) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.06.001 · Cited by 116 · cited 1×
“The biexponential model has also been shown elsewhere in literature to have a variable performance.(20,23,37) The parametric maps from voxel-by-voxel fitting in Figure 7 reflect the trends seen in the whole-ROI fitting in Figure 4.”
MethodHu, Y., Ahmed, H. U., Carter, T. J., Arumainayagam, N., Lecornet, E., Barzell, W. E., Freeman, A., Nevoux, P., Hawkes, D. J., Villers, A. A., et al. (2012) · British Journal of Urology · doi:10.1111/j.1464-410x.2012.10933.x · Cited by 91 · cited 1×
“The standard procedure to provide a diagnosis of the disease is transrectal prostate biopsy, which is invasive with possible unpleasant adverse effects(2) and is prone to error.(3) Imaging-based diagnostic strategies, using techniques such as multiparametric magnetic resonance imaging (MRI), show great promise,(4) pro…”
MethodSelf-citationNew Insights into Tumor Microstructure Using Temporal Diffusion Spectroscopy
Colvin, D. C., Yankeelov, T. E., Does, M. D., Yue, Z., Quarles, C. C., & Gore, J. C. (2008) · Cancer Research · doi:10.1158/0008-5472.can-08-0832 · Cited by 74
Concia, M., Sprinkart, A. M., Penner, A.-H., Brossart, P., Gieseke, J., Schild, H. H., Willinek, W. A., & Mürtz, P. (2013) · Investigative Radiology · doi:10.1097/rli.0b013e3182a71cc3 · Cited by 67
Colvin, D. C., Loveless, M. E., Does, M. D., Yue, Z., Yankeelov, T. E., & Gore, J. C. (2010) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2010.10.003 · Cited by 56
Bourne, R., Panagiotaki, E., Bongers, A., Sved, P. D., Watson, G., & Alexander, D. C. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25032 · Cited by 48 · cited 3×
“Intravoxel incoherent motion characterizes water dispersion as a combination of a slow component associated with Brownian motion and a fast component associated with the bulk motion of molecules inside microcapillaries.14,15 It has been used to study various cancer types such as breast,16 prostate,9 and pancreatic17,1…”
BackgroundSelf-citationMazaheri, Y., Vargas, H. A., Akın, O., Goldman, D. A., & Hricak, H. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22888 · Cited by 39 · cited 1×
“Copyright © 2015 Wolters Kluwer H cancer have also assessed IVIM and kurtosis techniques; however, these models also lack specificity to the underlying microstructure, with significant overlap of parameter values between benign and cancerous tissue.(11,19,21) The VERDICT model has the potential to overcome limitations…”
Background
Cited by
Weakly-supervised convolutional neural networks for multimodal image registration
Hu, Y., Modat, M., Gibson, E., Li, W., Ghavami, N., Bonmati, E., Wang, G., Bandula, S., Moore, C. M., Emberton, M., et al. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.07.002 · Cited by 458
Imaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
Self-citationRosenkrantz, A. B., Padhani, A. R., Chenevert, T. L., Koh, D., De Keyzer, F., Taouli, B., & Le Bihan, D. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24985 · Cited by 381
Diffusion MRI of cancer: From low to high b‐values
Tang, L., & Zhou, X. J. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26293 · Cited by 223
“One of these models, VERDICT, however, has been developed for cancer applications and successfully applied to colorectal and prostate cancers.(12) VERDICT divides each voxel into three compartments to capture the main tumorous tissue features that influence the DWI signal.”
MethodJones, D. K., Alexander, D. C., Bowtell, R., Cercignani, M., Dell'Acqua, F., McHugh, D. J., Miller, K. L., Palombo, M., Parker, G. J. M., Rudrapatna, U. S., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.05.047 · Cited by 183
Self-citation
Metadata
- Authors
- Panagiotaki, E., Chan, R. W., Dikaios, N., Ahmed, H. U., O’Callaghan, J., Freeman, A., Atkinson, D., Punwani, S., Hawkes, D. J., & Alexander, D. C.
- Venue
- Investigative Radiology
- Published
- 2015-04
- Volume
- 50
- Issue
- 4
- Pages
- 218-227
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W1994587808
- Cited by
- 184
- References
- 32
- FWCI
- 8.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.