Recent and Upcoming Technological Developments in Computed Tomography: High Speed, Low Dose, Deep Learning, Multienergy
The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
The advent of computed tomography (CT) has revolutionized radiology, and this revolution is still going on. Starting as a pure head scanner, modern CT systems are now able to perform whole-body examinations within a couple of seconds in isotropic resolution, single-rotation whole-organ perfusion, and temporal resolution to fulfill the needs of cardiac CT. Because of the increasing number of CT examinations in all age groups and overall medical-driven radiation exposure, dose reduction remains a hot topic. Although fast gantry rotation, broad detector arrays, and different dual-energy solutions were main topics in the past years, new techniques such as photon counting detectors, powerful x-ray tubes for low-kV scanning, automated image preprocessing, and machine learning algorithms have moved into focus today. The aim of this article is to give an overview of the technical specifications of up-to-date available CT systems and recent hardware and software innovations for CT systems in the near future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Image-to-Image Translation with Conditional Adversarial Networks
Isola, P., Zhu, J.-Y., Zhou, T., & Efros, A. A. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.632 · Cited by 22,930
Multilayer feedforward networks are universal approximators
Hornik, K., Stinchcombe, M., & White, H. (1989) · Neural Networks · doi:10.1016/0893-6080(89)90020-8 · Cited by 21,728
GAN(Generative Adversarial Nets)
(2017) · Journal of Japan Society for Fuzzy Theory and Intelligent Informatics · doi:10.3156/jsoft.29.5_177_2 · Cited by 19,270
Photon-counting CT: Technical Principles and Clinical Prospects
Willemink, M. J., Persson, M., Pourmorteza, A., Pelc, N. J., & Fleischmann, D. (2018) · Radiology · doi:10.1148/radiol.2018172656 · Cited by 1,326
Generative Adversarial Networks for Noise Reduction in Low-Dose CT
Wolterink, J. M., Leiner, T., Viergever, M. A., & Isgum, I. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2708987 · Cited by 1,037
Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography
Zhang, Y., & Yu, H. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823083 · Cited by 493
Evaluation of a prototype dual‐energy computed tomographic apparatus. I. Phantom studies
Kalender, W. A., Perman, W. H., Vetter, J. R., & Klotz, E. (1986) · Medical Physics · doi:10.1118/1.595958 · Cited by 451
Quantitative Bone Mineral Analysis Using Dual Energy Computed Tomography
GENANT, H. K., & BOYD, D. (1977) · Investigative Radiology · doi:10.1097/00004424-197711000-00015 · Cited by 397
Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
Kalender, W. A., Wolf, H., & Suess, C. (1999) · Medical Physics · doi:10.1118/1.598738 · Cited by 345
Kachelrieß, M., Watzke, O., & Kalender, W. A. (2001) · Medical Physics · doi:10.1118/1.1358303 · Cited by 311
Self-citationDetector-based spectral CT with a novel dual-layer technology: principles and applications
Rassouli, N., Etesami, M., Dhanantwari, A., & Rajiah, P. (2017) · Insights into Imaging · doi:10.1007/s13244-017-0571-4 · Cited by 300
Gutjahr, R., Halaweish, A. F., Yu, Z., Leng, S., Yu, L., Li, Z., Jorgensen, S. M., Ritman, E. L., Kappler, S., & McCollough, C. H. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000251 · Cited by 282
Greess, H., Wolf, H., Baum, U., Lell, M., Pirkl, M., Kalender, W., & Bautz, W. A. (2000) · European Radiology · doi:10.1007/s003300050062 · Cited by 230
Self-citationLeng, S., Rajendran, K., Gong, H., Zhou, W., Halaweish, A. F., Henning, A., Kappler, S., Baer, M., Fletcher, J. G., & McCollough, C. H. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000488 · Cited by 208
Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience
Pourmorteza, A., Symons, R., Sandfort, V., Mallek, M., Fuld, M. K., Henderson, G., Jones, E. C., Malayeri, A. A., Folio, L. R., & Bluemke, D. A. (2016) · Radiology · doi:10.1148/radiol.2016152601 · Cited by 207
Symons, R., Reich, D. S., Bagheri, M., Cork, T. E., Krauss, B., Ulzheimer, S., Kappler, S., Bluemke, D. A., & Pourmorteza, A. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000418 · Cited by 191
CT sinogram‐consistency learning for metal‐induced beam hardening correction
Park, H. S., Lee, S. M., Kim, H. P., Seo, J. K., & Chung, Y. E. (2018) · Medical Physics · doi:10.1002/mp.13199 · Cited by 169
Bartlett, D. J., Koo, C. W., Bartholmai, B. J., Rajendran, K., Weaver, J. M., Halaweish, A. F., Leng, S., McCollough, C. H., & Fletcher, J. G. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000524 · Cited by 164
Model-Based Iterative Reconstruction Technique for Ultralow-Dose Chest CT
Katsura, M., Matsuda, I., Akahane, M., Yasaka, K., Hanaoka, S., Akai, H., Sato, J., Kunimatsu, A., & Ohtomo, K. (2013) · Investigative Radiology · doi:10.1097/rli.0b013e31827efc3a · Cited by 149
Vetter, J. R., Perman, W. H., Kalender, W. A., Mazess, R. B., & Holden, J. E. (1986) · Medical Physics · doi:10.1118/1.595951 · Cited by 138
Kim, Y., Kim, Y. K., Lee, B. E., Lee, S. J., Ryu, Y. J., Lee, J. H., & Chang, J. H. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.13629 · Cited by 129
Dose Efficiency of Quarter-Millimeter Photon-Counting Computed Tomography: First-in-Human Results
Pourmorteza, A., Symons, R., Henning, A., Ulzheimer, S., & Bluemke, D. A. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000463 · Cited by 125
Maier, J., Eulig, E., Vöth, T., Knaup, M., Kuntz, J., Sawall, S., & Kachelrieß, M. (2018) · Medical Physics · doi:10.1002/mp.13274 · Cited by 108
Self-citationHaaga, J. R., Miraldi, F. D., MacIntyre, W. J., Lipuma, J. P., Bryan, P. J., & Wiesen, E. (1981) · Radiology · doi:10.1148/radiology.138.2.7455129 · Cited by 107
Newell, J. D., Fuld, M. K., Allmendinger, T., Sieren, J., Chan, K., Guo, J., & Hoffman, E. A. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000093 · Cited by 101
Messerli, M., Kluckert, T., Knitel, M., Waelti, S. L., Desbiolles, L. M., Rengier, F., Warschkow, R., Bauer, R. W., Alkadhi, H., Leschka, S., et al. (2017) · European Radiology · doi:10.1007/s00330-017-4739-6 · Cited by 95
Lee, K. H., Lee, J. M., Moon, S. K., Baek, J. H., Park, J. H., Flohr, T. G., Kim, K. W., Kim, S., Han, J. K., & Choi, B. I. (2012) · Radiology · doi:10.1148/radiol.12112434 · Cited by 94
Saltybaeva, N., Schmidt, B., Wimmer, A., Flohr, T., & Alkadhi, H. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000482 · Cited by 91
Prospects of deep learning for medical imaging
Kim, J., Hong, J., & Park, H. (2018) · Precision and Future Medicine · doi:10.23838/pfm.2018.00030 · Cited by 90
Martin, S. S., Weidinger, S., Czwikla, R., Kaltenbach, B., Albrecht, M. H., Lenga, L., Vogl, T. J., & Wichmann, J. L. (2017) · Investigative Radiology · doi:10.1097/rli.0000000000000425 · Cited by 87
Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography
Papadakis, A. E., & Damilakis, J. E. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000537 · Cited by 84
von Spiczak, J., Mannil, M., Peters, B., Hickethier, T., Baer, M., Henning, A., Schmidt, B. T., Flohr, T. G., Manka, R., Maintz, D. C., et al. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000485 · Cited by 82
Normalized Metal Artifact Reduction in Head and Neck Computed Tomography
Lell, M., Meyer, E., Kuefner, M. A., May, M. S., Raupach, R., Uder, M., & Kachelrieß, M. (2012) · Investigative Radiology · doi:10.1097/rli.0b013e3182532f17 · Cited by 76
Self-citationWeis, M., Henzler, T., Nance, J. W., Haubenreisser, H., Meyer, M., Sudarski, S., Schoenberg, S. O., Neff, K. W., & Hagelstein, C. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000325 · Cited by 71
Leithner, D., Wichmann, J. L., Vogl, T. J., Trommer, J., Martin, S. S., Scholtz, J., Bodelle, B., Cecco, C. N. D., Duguay, T. M., Nance, J. W., et al. (2017) · Investigative Radiology · doi:10.1097/rli.0000000000000387 · Cited by 71
To bin or not to bin? The effect of CT system limiting resolution on noise and detectability
Baek, J., Pineda, A. R., & Pelc, N. J. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/5/1433 · Cited by 68
2.5D Deep Learning For CT Image Reconstruction Using A Multi-GPU Implementation
Ziabari, A., Ye, D. H., Srivastava, S., Sauer, K. D., Thibault, J., & Bouman, C. A. (2018) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/acssc.2018.8645364 · Cited by 64
Lell, M., May, M. S., Brand, M., Eller, A., Buder, T., Hofmann, E., Uder, M., & Wuest, W. (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4270 · Cited by 61
Self-citationMannil, M., Ramachandran, J., Martini, I. V. D., Wegener, S., Schmidt, B. T., Flohr, T. G., Krauß, B., Valavanis, A., Alkadhi, H., & Winklhofer, S. F.-X. (2017) · Investigative Radiology · doi:10.1097/rli.0000000000000391 · Cited by 61
Weiß, J., Notohamiprodjo, M., Bongers, M. N., Schabel, C., Mangold, S., Nikolaou, K., Bamberg, F., & Othman, M. I. A. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000319 · Cited by 50
Cardiac motion correction based on partial angle reconstructed images in x‐ray CT
Kim, S., Chang, Y., & Ra, J. B. (2015) · Medical Physics · doi:10.1118/1.4918580 · Cited by 48
Khodarahmi, I., Haroun, R. R., Lee, M., Fung, G. S. K., Fuld, M. K., Schon, L. C., Fishman, E. K., & Fritz, J. M. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000497 · Cited by 47
Hendriks, B. M. F., Eijsvoogel, N. G., Kok, M., Martens, B., Wildberger, J. E., & Das, M. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000443 · Cited by 43
Andersson, K. M., Norrman, E., Geijer, H., Krauss, W., Cao, Y., Jendeberg, J., Geijer, M., Lidén, M., & Thunberg, P. (2016) · British Journal of Radiology · doi:10.1259/bjr.20150993 · Cited by 42
Andreini, D., Pontone, G., Mushtaq, S., Bertella, E., Conte, E., Segurini, C., Baggiano, A., Bartorelli, A. L., Annoni, A. D., Formenti, A., et al. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jev033 · Cited by 39
Pulmonary Disease in Cystic Fibrosis: Assessment with Chest CT at Chest Radiography Dose Levels
Ernst, C. W., Basten, I. A., Ilsen, B., Buls, N., Gompel, G. V., Wachter, E. D., Nieboer, K., Verhelle, F., Malfroot, A., Coomans, D. H., et al. (2014) · Radiology · doi:10.1148/radiol.14132201 · Cited by 39
van Ommen, F., de Jong, H. W. A. M., Dankbaar, J. W., Bennink, E. H., Leiner, T., & Schilham, A. M. R. (2019) · European Journal of Radiology · doi:10.1016/j.ejrad.2019.01.011 · Cited by 37
Taguchi, K., Itoh, T., Fuld, M. K., Fournié, É., Lee, O., & Noguchi, K. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000461 · Cited by 29
Chest CT Scan at Radiation Dose of a Posteroanterior and Lateral Chest Radiograph Series
Hu-Wang, E., Schuzer, J. L., Rollison, S. F., Leifer, E., Steveson, C., Gopalakrishnan, V., Yao, J., Machado, T. R., Jones, A. M., Julien-Williams, P. A., et al. (2018) · CHEST Journal · doi:10.1016/j.chest.2018.09.007 · Cited by 24
Real-Time Patient-Specific CT Dose Estimation using a Deep Convolutional Neural Network
Maier, J., Eulig, E., Dorn, S., Sawall, S., & Kachelries, M. (2018) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2018.8824626 · Cited by 23
Hokamp, N. G., Abdullayev, N., Persigehl, T., Schlaak, M. S., Wybranski, C., Holz, J. A., Streichert, T., Alkadhi, H., Maintz, D. C., & Haneder, S. (2018) · European Radiology · doi:10.1007/s00330-018-5744-0 · Cited by 22
Cardiac Motion Correction for Helical CT Scan With an Ordinary Pitch
Kim, S., Chang, Y., & Ra, J. B. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2817594 · Cited by 15
Cited by
Transformers in medical imaging: A survey
Shamshad, F., Khan, S., Zamir, S. W., Khan, M. H., Hayat, M., Khan, F. S., & Fu, H. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102802 · Cited by 1,296
Euler, A., Nowak, T., Bucher, B., Eberhard, M., Schmidt, B., Flohr, T. G., Frey, D., Distler, O., & Alkadhi, H. (2021) · Investigative Radiology · doi:10.1097/rli.0000000000000781 · Cited by 19
Simplified size adjusted dose reference levels for adult CT examinations: A regional study
Moghadam, N., Lecomte, R., Mercure, S., Rehani, M. M., & Nassiri, M. A. (2021) · European Journal of Radiology · doi:10.1016/j.ejrad.2021.109861 · Cited by 16
Metadata
- Authors
- Lell, M. M., & Kachelrieß, M.
- Venue
- Investigative Radiology
- Published
- 2019-09-17
- Volume
- 55
- Issue
- 1
- Pages
- 8-19
- ISSN
- 0020-9996 (ISSN-L)
- 1536-0210
- OpenAlex
- W2974549447
- Cited by
- 254
- References
- 53
- FWCI
- 10.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.