The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
A schlieren optical study of the human cough with and without wearing masks for aerosol infection control
Open accessAbstract
Various infectious agents are known to be transmitted naturally via respiratory aerosols produced by infected patients. Such aerosols may be produced during normal activities by breathing, talking, coughing and sneezing. The schlieren optical method, previously applied mostly in engineering and physics, can be effectively used here to visualize airflows around human subjects in such indoor situations, non-intrusively and without the need for either tracer gas or airborne particles. It accomplishes this by rendering visible the optical phase gradients owing to real-time changes in air temperature. In this study, schlieren video records are obtained of human volunteers coughing with and without wearing standard surgical and N95 masks. The object is to characterize the exhaled airflows and evaluate the effect of these commonly used masks on the fluid-dynamic mechanisms that spread infection by coughing. Further, a high-speed schlieren video of a single cough is analysed by a computerized method of tracking individual turbulent eddies, demonstrating the non-intrusive velocimetry of the expelled airflow. Results show that human coughing projects a rapid turbulent jet into the surrounding air, but that wearing a surgical or N95 mask thwarts this natural mechanism of transmitting airborne infection, either by blocking the formation of the jet (N95 mask), or by redirecting it in a less harmful direction (surgical mask).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pope, S. B. (2000) · Cambridge University Press eBooks · doi:10.1017/cbo9780511840531 · Cited by 8,477
Evidence of Airborne Transmission of the Severe Acute Respiratory Syndrome Virus
Yu, I. T. S., Li, Y., Wong, T. W., Tam, W., Chan, A. T., Lee, J. H. W., Leung, D. Y. C., & Ho, T. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032867 · Cited by 1,256
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055
Self-citationHow far droplets can move in indoor environments ? revisiting the Wells evaporation?falling curve
Xie, X., Li, Y., Chwang, A. T. Y., Ho, P. L., & Seto, W. H. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00469.x · Cited by 966
Review of Aerosol Transmission of Influenza A virus
Tellier, R. (2006) · Emerging Infectious Diseases · doi:10.3201/eid1211.060426 · Cited by 803
Transmission of influenza A in human beings
Brankston, G., Gitterman, L., Hirji, Z., Lemieux, C., & Gardam, M. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70029-4 · Cited by 744
Tang, J. W., Li, Y., Eames, I., Chan, P. K. S., & Ridgway, G. L. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.05.022 · Cited by 667
Self-citationExhaled droplets due to talking and coughing
Xie, X., Li, Y., Sun, H., & Liu, L. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0388.focus · Cited by 527
Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong
Li, Y., Huang, X., Yu, I. T. S., Wong, T. W., & Qian, H. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00317.x · Cited by 414
Inhaling to mitigate exhaled bioaerosols
Edwards, D. A., Man, J. C., Brand, P., Katstra, J. P., Sommerer, K., Stone, H. A., Nardell, E., & Scheuch, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408159101 · Cited by 362
Cole, E. C., & Cook, C. E. (1998) · American Journal of Infection Control · doi:10.1016/s0196-6553(98)70046-x · Cited by 317
Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles
Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891010389 · Cited by 298 · cited 4×
“The N95, on the other hand, is designated a ‘particulate respirator and surgical mask’, and is approved by NIOSH (The National Institute for Occupational Safety and Health) (Qian et al. 1998).”
BackgroundInfluentialGlobal Physiology and Pathophysiology of Cough
McCool, F. D. (2006) · Chest · doi:10.1378/chest.129.1_suppl.48s · Cited by 298
Qian, H., Li, Y., Nielsen, P. V., Hyldgaard, C. E., Wong, T. W., & Chwang, A. T. Y. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00407.x · Cited by 294
Cluster of SARS among Medical Students Exposed to Single Patient, Hong Kong
Wong, T.-W., Lee, C.-K., Tam, W., Lau, J. T.-F., Yu, T.-S., Lui, S.-F., Chan, P. K. S., Li, Y., Bresee, J. S., Sung, J. J. Y., et al. (2004) · Emerging Infectious Diseases · doi:10.3201/eid1002.030452 · Cited by 265
Lee, S.-A., Grinshpun, S. A., & Reponen, T. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men005 · Cited by 235 · cited 3×
“Previous studies on surgical and N95 masks have found that their efficiency at removing aerosol particles depends upon several factors, including the velocity of the airflow passing through the mask, the degree of leakage around the mask, and the particle size distribution to be filtered (Chen & Willeke 1992; Weber et…”
BackgroundA Computational and Experimental Investigation of the Human Thermal Plume
Craven, B. A., & Settles, G. S. (2006) · Journal of Fluids Engineering · doi:10.1115/1.2353274 · Cited by 217
Self-citationJohnson, D. F., Druce, J. D., Birch, C., & Grayson, M. L. (2009) · Clinical Infectious Diseases · doi:10.1086/600041 · Cited by 211 · cited 2×
“Both masks were found to be of similar efficacy in this regard ( Johnson et al. 2009).”
BackgroundNoninvasive Positive-Pressure Ventilation
Hui, D. S. C., Hall, S. D., Chan, M. T. V., Chow, B., Tsou, J. Y., Joynt, G. M., Sullivan, C. E., & Sung, J. J. �. (2006) · CHEST Journal · doi:10.1378/chest.130.3.730 · Cited by 202
Li, Y., Duan, S., Yu, I. T. S., & Wong, T. W. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00318.x · Cited by 194
Man and his thermal environment
(1986) · Applied Ergonomics · doi:10.1016/0003-6870(86)90056-6 · Cited by 191
Aerosol penetration and leakae characteristics of masks used in the health care industry
Weber, A. M., Willeke, K., Marchloni, R., Myojo, T., McKay, R. T., Donnelly, J., & Liebhaber, F. B. (1993) · American Journal of Infection Control · doi:10.1016/0196-6553(93)90027-2 · Cited by 156
AERODYNAMICS OF THE HUMAN MICROENVIRONMENT
Lewis, H. E., Foster, A. R., Bj, M., Cox, R., & Clark, R. P. (1969) · The Lancet · doi:10.1016/s0140-6736(69)92220-x · Cited by 148
Influence of movements on contaminant transport in an operating room
Brohus, H., Balling, K. D., & Jeppesen, D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00454.x · Cited by 144
Personalized ventilation as a control measure for airborne transmissible disease spread
Pantelic, J., Sze-To, G. N., Tham, K. W., Chao, C. Y. H., & Khoo, Y. C. M. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0311.focus · Cited by 136
Temporal-Spatial Analysis of Severe Acute Respiratory Syndrome among Hospital Inpatients
Yu, I. T. S., Wong, T. W., Chiu, Y. L., Lee, N. L. S., & Li, Y. (2005) · Clinical Infectious Diseases · doi:10.1086/428735 · Cited by 128
Chen, S.-K., Vesley, D., Brosseau, L. M., & Vincent, J. H. (1994) · American Journal of Infection Control · doi:10.1016/0196-6553(94)90116-3 · Cited by 124
Schlieren “PIV” for turbulent flows
Jonassen, D. R., Settles, G. S., & Tronosky, M. D. (2005) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2005.04.004 · Cited by 123
Self-citationAerosol penetration through surgical masks
Chen, C.-C., & Willeke, K. (1992) · American Journal of Infection Control · doi:10.1016/s0196-6553(05)80143-9 · Cited by 118
Tang, J. W.-T., Eames, I., Li, Y., Taha, Y., Wilson, P., Bellingan, G. J., Ward, K. N., & Breuer, J. (2005) · Journal of Hospital Infection · doi:10.1016/j.jhin.2005.05.017 · Cited by 113
Self-citationSniffers: Fluid-Dynamic Sampling for Olfactory Trace Detection in Nature and Homeland Security—
Settles, G. S. (2005) · Journal of Fluids Engineering · doi:10.1115/1.1891146 · Cited by 110
Self-citationExhaled Air and Aerosolized Droplet Dispersion During Application of a Jet Nebulizer
Hui, D. S. C., Chow, B., Chu, L. C. Y., Ng, S. S., Hall, S. D., Gin, T., & Chan, M. T. V. (2009) · CHEST Journal · doi:10.1378/chest.08-1998 · Cited by 101
Man and His Thermal Environment
Gates, D. M., Clark, R. P., & Edholm, O. G. (1986) · Arctic and Alpine Research · doi:10.2307/1551099 · Cited by 87
Transmission and Prevention of Occupational Infections in Orthopaedic Surgeons
Wong, K. C., & Leung, K. (2004) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200405000-00029 · Cited by 82
Tang, J. W.-T., & Settles, G. S. (2008) · New England Journal of Medicine · doi:10.1056/nejmicm072576 · Cited by 72
Self-citationCharacterizing and monitoring respiratory aerosols by light scattering
Pan, Y., Aptowicz, K. B., Chang, R. K., Hart, M. B., & Eversole, J. D. (2003) · Optics Letters · doi:10.1364/ol.28.000589 · Cited by 71
Computational Study of the Wake and Contaminant Transport of a Walking Human
Edge, B. A., Paterson, E. G., & Settles, G. S. (2005) · Journal of Fluids Engineering · doi:10.1115/1.2013291 · Cited by 71
Self-citationAirflow and droplet spreading around oxygen masks: A simulation model for infection control research
Ip, M., Tang, J. W.-T., Hui, D. S. C., Wong, A. L. N., Chan, M. T. V., Joynt, G. M., So, A. T. P., Hall, S. D., Chan, P. K. S., & Sung, J. J. �. (2007) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.05.007 · Cited by 66
Self-citationFLUID MECHANICS AND HOMELAND SECURITY
Settles, G. S. (2005) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.38.050304.092111 · Cited by 66
Self-citationVogel, A., Apitz, I., Freidank, S., & Dijkink, R. (2006) · Optics Letters · doi:10.1364/ol.31.001812 · Cited by 61
Bacterial survival in evaporating deposited droplets on a teflon-coated surface
Xie, X., Li, Y., Zhang, T., & Fang, H. H. P. (2006) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-006-0492-5 · Cited by 59
Transmission of influenza A in human beings
Tellier, R. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70269-4 · Cited by 55
Questioning Aerosol Transmission of Influenza
Lemieux, C., Brankston, G., Gitterman, L., Hirji, Z., & Gardam, M. A. (2007) · Emerging infectious diseases · doi:10.3201/eid1301.061202 · Cited by 51
Transmission of influenza A in human beings
Tang, J. W.-T., & Li, Y. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70268-2 · Cited by 36
Self-citationSARS transmission: language and droplet production
Inouye, S. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13874-3 · Cited by 31
Plume Emission, Shock Wave and Surface Wave Formation During Excimer Laser Ablation of the Cornea
Bor, Z., Hopp, B., Rácz, B., Szabó, G., Ratkay, I., Süveges, I., Füst, Á., & Mohay, J. (1993) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19930302-31 · Cited by 29
Cited by
Violent expiratory events: on coughing and sneezing
Bourouiba, L., Dehandschoewercker, E., & Bush, J. W. M. (2014) · Journal of Fluid Mechanics · doi:10.1017/jfm.2014.88 · Cited by 828
Airborne spread of infectious agents in the indoor environment
Wei, J., & Li, Y. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2016.06.003 · Cited by 519
Face Masks in the New COVID-19 Normal: Materials, Testing, and Perspectives
Chua, M. H., Cheng, W., Goh, S. S., Kong, J., Li, B., Lim, J. Y. C., Mao, L., Wang, S., Xue, K., Yang, L., et al. (2020) · Research · doi:10.34133/2020/7286735 · Cited by 495
Mittal, R., Ni, R., & Seo, J.-H. (2020) · Journal of Fluid Mechanics · doi:10.1017/jfm.2020.330 · Cited by 494
Asadi, S., Cappa, C. D., Barreda, S., Wexler, A. S., Bouvier, N. M., & Ristenpart, W. D. (2020) · Scientific Reports · doi:10.1038/s41598-020-72798-7 · Cited by 480
Metadata
- Authors
- Tang, J. W., Liebner, T. J., Craven, B. A., & Settles, G. S.
- Venue
- Journal of The Royal Society Interface
- Publisher
- The Royal Society
- Published
- 2009-10-08
- Volume
- 6
- Issue
- suppl_6
- Pages
- S727-36
- ISSN
- 1742-5662 (ISSN-L)
- 1742-5689
- OpenAlex
- W2105068983
- Cited by
- 300
- References
- 46
- FWCI
- 6.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.