The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Probing mechanical properties of living cells by atomic force microscopy with blunted pyramidal cantilever tips
Abstract
Atomic force microscopy (AFM) allows the acquisition of high-resolution images and the measurement of mechanical properties of living cells under physiological conditions. AFM cantilevers with blunted pyramidal tips are commonly used to obtain images of living cells. Measurement of mechanical properties with these tips requires a contact model that takes into account their blunted geometry. The aim of this work was to develop a contact model of a blunted pyramidal tip and to assess the suitability of pyramidal tips for probing mechanical properties of soft gels and living cells. We developed a contact model of a blunted pyramidal tip indenting an elastic half-space. We measured Young's modulus (E) and the complex shear modulus (G*= G' +i G" ) of agarose gels and A549 alveolar epithelial cells with pyramidal tips and compared them with those obtained with spherical tips. The gels exhibited an elastic behavior with almost coincident loading and unloading force curves and negligible values of G". E fell sharply with indentation up to approximately 300 nm , showing a linear regime for deeper indentations. A similar indentation dependence of E with twofold lower values at the linear regime was obtained with the spherical tip fitted with Hertz's model. The dependence of E on indentation in cells paralleled that found in gels. Cells exhibited viscoelastic behavior with G"/G' approximately 1/4 . Pyramidal tips commonly used for AFM imaging are suitable for probing mechanical properties of soft gels and living cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johnson, K. L. (1985) · Cambridge University Press eBooks · doi:10.1017/cbo9781139171731 · Cited by 7,796
Sneddon, I. N. (1965) · International Journal of Engineering Science · doi:10.1016/0020-7225(65)90019-4 · Cited by 4,346
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
On the Contact of Elastic Solids
Hertz (1882) · Journal für die reine und angewandte Mathematik (Crelles Journal) · Cited by 3,051
Determination of Elastic Moduli of Thin Layers of Soft Material Using the Atomic Force Microscope
Dimitriadis, E. K., Horkay, F., Maresca, J., Kachar, B., & Chadwick, R. S. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75620-8 · Cited by 1,230
Advanced strength and applied elasticity
Ugural, A. C., & Fenster, S. K. (1975) · Cited by 991
Rotsch, C., & Radmacher, M. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76614-8 · Cited by 971
Microfabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576520 · Cited by 747
Microrheology of Human Lung Epithelial Cells Measured by Atomic Force Microscopy
Alcaraz, J., Buscemi, L., Grabulosa, M., Trepat, X., Fabry, B., Farré, R., & Navajas, D. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75014-0 · Cited by 740
Self-citationMathur, A. B., Collinsworth, A. M., Reichert, W. M., Kraus, W. E., & Truskey, G. A. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00149-x · Cited by 589
New Insight into Agarose Gel Mechanical Properties
Normand, V., Lootens, D. L., Amici, E., Plucknett, K. P., & Aymard, P. (2000) · Biomacromolecules · doi:10.1021/bm005583j · Cited by 558
Relative Microelastic Mapping of Living Cells by Atomic Force Microscopy
A-Hassan, E., Heinz, W. F., Antonik, M. D., D’Costa, N. P., Nageswaran, S., Schoenenberger, C.-A., & Hoh, J. H. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77868-3 · Cited by 552
Cell mechanics and mechanotransduction: pathways, probes, and physiology
Huang, H., Kamm, R. D., & Lee, R. T. (2004) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00559.2003 · Cited by 548
Scanning Probe-Based Frequency-Dependent Microrheology of Polymer Gels and Biological Cells
Mahaffy, R. E., Shih, C. K., MacKintosh, F. C., & Käs, J. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.880 · Cited by 509
Nanoscale Mapping of the Elasticity of Microbial Cells by Atomic Force Microscopy
Touhami, A., Nysten, B., & Dufrêne, Y. F. (2003) · Langmuir · doi:10.1021/la034136x · Cited by 466
Mahaffy, R. E., Park, S., Gerde, E., Käs, J., & Shih, C. K. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74245-9 · Cited by 460
Stolz, M., Raiteri, R., Daniels, A. U., VanLandingham, M. R., Baschong, W., & Aebi, U. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74375-1 · Cited by 454
Actin Filament Dynamics in Living Glial Cells Imaged by Atomic Force Microscopy
Henderson, E., Haydon, P. G., & Sakaguchi, D. S. (1992) · Science · doi:10.1126/science.1411511 · Cited by 415
Imaging soft samples with the atomic force microscope: gelatin in water and propanol
Radmacher, M., Fritz, M., & Hansma, P. K. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)79897-6 · Cited by 379
Wu, H. W., Kuhn, T., & Moy, V. T. (1998) · Scanning · doi:10.1002/sca.1998.4950200504 · Cited by 334
Single Cell Mechanotransduction and Its Modulation Analyzed by Atomic Force Microscope Indentation
Charras, G. T., & Horton, M. A. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75638-5 · Cited by 281
Bilodeau, G. G. (1992) · Journal of Applied Mechanics · doi:10.1115/1.2893754 · Cited by 265
Costa, K. D., & Yin, F. C. P. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2835074 · Cited by 265
Shroff, S. G., Saner, D. R., & Lal, R. (1995) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1995.269.1.c286 · Cited by 260
Steric Forces Measured with the Atomic Force Microscope at Various Temperatures
Butt, H.-J., Kappl, M., Mueller, H., Raiteri, R., Meyer, W., & Rühe, J. (1999) · Langmuir · doi:10.1021/la981503+ · Cited by 233
Alcaraz, J., Buscemi, L., Puig-de-Morales, M., Colchero, J., Baró, A., & Navajas, D. (2002) · Langmuir · doi:10.1021/la0110850 · Cited by 188
Self-citationThermomechanical noise of a free v-shaped cantilever for atomic-force microscopy
Stark, R. W., Drobek, T., & Heckl, W. M. (2001) · Ultramicroscopy · doi:10.1016/s0304-3991(00)00077-2 · Cited by 179
Viscoelasticity of human alveolar epithelial cells subjected to stretch
Trepat, X., Grabulosa, M., Puig, F., Maksym, G. N., Navajas, D., & Farré, R. (2004) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00077.2004 · Cited by 173
Self-citationTowards a regional approach to cell mechanics
Heidemann, S. R., & Wirtz, D. (2004) · Trends in Cell Biology · doi:10.1016/j.tcb.2004.02.003 · Cited by 170
Fritz, M., Radmacher, M., & Gaub, H. E. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80963-4 · Cited by 150
Atomic force microscopy imaging of living cells: progress, problems and prospects
You, H. X., & Yu, L. (1999) · Methods in Cell Science · doi:10.1023/a:1009876320336 · Cited by 85
Evidence and Implications of Inhomogeneity in Tectorial Membrane Elasticity
Shoelson, B., Dimitriadis, E. K., Cai, H., Kachar, B., & Chadwick, R. S. (2004) · Biophysical Journal · doi:10.1529/biophysj.104.040774 · Cited by 68
Elastic deformations of tip and sample during atomic force microscope measurements
Heuberger, M. P., Dietler, G., & Schlapbach, L. (1996) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.588525 · Cited by 68
Cited by
Self-organizing optic-cup morphogenesis in three-dimensional culture
Eiraku, M., Takata, N., Ishibashi, H., Kawada, M., Sakakura, E., Okuda, S., Sekiguchi, K., Adachi, T., & Sasai, Y. (2011) · Nature · doi:10.1038/nature09941 · Cited by 2,001
Atomic force microscopy-based mechanobiology
Krieg, M., Fläschner, G., Alsteens, D., Gaub, B. M., Roos, W. H., Wuite, G. J. L., Gaub, H. E., Gerber, C., Dufrêne, Y. F., & Müller, D. J. (2018) · Nature Reviews Physics · doi:10.1038/s42254-018-0001-7 · Cited by 799
Indentation Versus Tensile Measurements of Young's Modulus for Soft Biological Tissues
McKee, C. T., Last, J. A., Russell, P., & Murphy, C. J. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0520 · Cited by 708
Elastic Modulus Determination of Normal and Glaucomatous Human Trabecular Meshwork
Last, J. A., Pan, T., Ding, Y., Reilly, C. M., Keller, K., Acott, T. S., Fautsch, M. P., Murphy, C. J., & Russell, P. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6342 · Cited by 386
Lin, D. C., Dimitriadis, E. K., & Horkay, F. (2007) · Journal of Biomechanical Engineering · doi:10.1115/1.2720924 · Cited by 324
Metadata
- Authors
- Rico, F., Roca-Cusachs, P., Gavara, N., Farré, R., Rotger, M., & Navajas, D.
- Venue
- Physical Review E
- Publisher
- American Physical Society (APS)
- Published
- 2005-08-29
- Volume
- 72
- Issue
- 2
- Pages
- 021914-021914
- ISSN
- 1539-3755 (ISSN-L)
- 1550-2376
- OpenAlex
- W2155143412
- Cited by
- 421
- References
- 33
- FWCI
- 6.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.