Neutral Atom Frequency Reference in the Deep Ultraviolet withFractional Uncertainty=5.7×10−15
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
We present an assessment of the ($6{s}^{2}$) $^{1}S_{0}\ensuremath{\leftrightarrow}(6s6p)^{3}P_{0}$ clock transition frequency in $^{199}\mathrm{Hg}$ with an uncertainty reduction of nearly 3 orders of magnitude and demonstrate an atomic quality factor $Q$ of $\ensuremath{\sim}{10}^{14}$. The $^{199}\mathrm{Hg}$ atoms are confined in a vertical lattice trap with light at the newly determined magic wavelength of $362.5697\ifmmode\pm\else\textpm\fi{}0.0011\text{ }\text{ }\mathrm{nm}$ and at a lattice depth of $20{E}_{R}$. The atoms are loaded from a single-stage magneto-optical trap with cooling light at 253.7 nm. The high $Q$ factor is obtained with an 80 ms Rabi pulse at 265.6 nm. We find the frequency of the clock transition to be $1\text{ }128\text{ }575\text{ }290\text{ }808\text{ }162.0\ifmmode\pm\else\textpm\fi{}6.4(\mathrm{syst})\ifmmode\pm\else\textpm\fi{}0.3(\mathrm{stat})\text{ }\text{ }\mathrm{Hz}$ (i.e., with $\mathrm{\text{fractional uncertainty}}=5.7\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$). Neither an atom number nor second order Zeeman dependence has yet been detected. Only three laser wavelengths are used for the cooling, lattice trapping, probing, and detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
Porsev, S. G., & Derevianko, A. (2006) · Physical Review A · doi:10.1103/physreva.74.020502 · Cited by 279
Fortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Comparing a mercury optical lattice clock with microwave and optical frequency standards
Tyumenev, R., Favier, M., Bilicki, S., Bookjans, E., Targat, R. L., Lodewyck, J., Nicolodi, D., Coq, Y. L., Abgrall, M., Guéna, J., et al. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/11/113002 · Cited by 85
Self-citationAtomic clocks: new prospects in metrology and geodesy
Delva, P., & Lodewyck, J. (2013) · arXiv · doi:10.48550/arxiv.1308.6766 · Cited by 40
Metadata
- Authors
- McFerran, J. J., Yi, L., Mejri, S., Di Manno, S., Zhang, W., Guéna, J., Le Coq, Y., & Bize, S.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2012-05-04
- Volume
- 108
- Issue
- 18
- Pages
- 183004-183004
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2413355360
- Cited by
- 89
- References
- 5
- FWCI
- 5.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neutral Atom Frequency Reference in the Deep Ultraviolet withFractional Uncertainty=5.7×10−15. https://app.cochat.ai/papers/10.1103/physrevlett.108.183004
- The paper
- McFerran, J. J., Yi, L., Mejri, S., Di Manno, S., Zhang, W., Guéna, J., Le Coq, Y., & Bize, S. (2012). Neutral Atom Frequency Reference in the Deep Ultraviolet withFractional Uncertainty=5.7×10−15. Physical Review Letters. https://doi.org/10.1103/physrevlett.108.183004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.