The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
High Resolution 3D X-Ray Diffraction Microscopy
Abstract
We have imaged a 2D buried Ni nanostructure at 8 nm resolution using coherent x-ray diffraction and the oversampling phasing method. By employing a 3D imaging reconstruction algorithm, for the first time we have experimentally determined the 3D structure of a noncrystalline nanostructured material at 50 nm resolution. The 2D and 3D imaging resolution is currently limited by the exposure time and the computing power, while the ultimate resolution is limited by the x-ray wavelengths. We believe these results pave the way for the development of atomic resolution 3D x-ray diffraction microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596
Surface Studies by Scanning Tunneling Microscopy
Binnig, G., Rohrer, H., Gerber, C., & Weibel, E. (1982) · Physical Review Letters · doi:10.1103/physrevlett.49.57 · Cited by 4,777
Potential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022
Miao, J., Charalambous, P., Kirz, J., & Sayre, D. (1999) · Nature · doi:10.1038/22498 · Cited by 1,976
Self-citationHenderson, R. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s003358350000305x · Cited by 1,194
Experimental High-Resolution Electron Microscopy
Spence, J. C. H., & Crewe, A. V. (1981) · Physics Today · doi:10.1063/1.2914772 · Cited by 712
Quantitative Phase Imaging Using Hard X Rays
Nugent, K. A., Gureyev, T. E., Cookson, D. F., Paganin, D., & Barnea, Z. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.2961 · Cited by 675
Soft X-ray microscopes and their biological applications
Kirz, J., Jacobsen, C., & Howells, M. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500003139 · Cited by 672
Miao, J., Hodgson, K. O., & Sayre, D. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.111083998 · Cited by 154
Self-citationExperimental High-Resolution Electron Microscopy
Stobbs, W. M. (1981) · Physics Bulletin · doi:10.1088/0031-9112/32/11/037 · Cited by 148
Cited by
Phase Retrieval with Application to Optical Imaging: A contemporary overview
Shechtman, Y., Eldar, Y. C., Cohen, O., Chapman, H. N., Miao, J., & Segev, M. (2015) · IEEE Signal Processing Magazine · doi:10.1109/msp.2014.2352673 · Cited by 1,131
Self-citationPhase Retrieval via Wirtinger Flow: Theory and Algorithms
Candès, E. J., Li, X., & Soltanolkotabi, M. (2015) · IEEE Transactions on Information Theory · doi:10.1109/tit.2015.2399924 · Cited by 1,049
X-ray image reconstruction from a diffraction pattern alone
Marchesini, S., He, H., Chapman, H. N., Hau-Riege, S. P., Noy, A., Howells, M. R., Weierstall, U., & Spence, J. C. H. (2003) · Physical Review B · doi:10.1103/physrevb.68.140101 · Cited by 883
Beyond crystallography: Diffractive imaging using coherent x-ray light sources
Miao, J., Ishikawa, T., Robinson, I. K., & Murnane, M. M. (2015) · Science · doi:10.1126/science.aaa1394 · Cited by 808
Self-citationProbing surface and interface morphology with Grazing Incidence Small Angle X-Ray Scattering
Renaud, G., Lazzari, R., & Leroy, F. (2009) · Surface Science Reports · doi:10.1016/j.surfrep.2009.07.002 · Cited by 756
Coherent lensless X-ray imaging
Chapman, H. N., & Nugent, K. A. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.240 · Cited by 591
Invited Article: A unified evaluation of iterative projection algorithms for phase retrieval
Marchesini, S. (2007) · Review of Scientific Instruments · doi:10.1063/1.2403783 · Cited by 573
Biological imaging by soft x-ray diffraction microscopy
Shapiro, D., Thibault, P., Beetz, T., Elser, V., Howells, M., Jacobsen, C., Kirz, J., Lima, E., Miao, H., Neiman, A. M., et al. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503305102 · Cited by 554
Generation of 3D representative volume elements for heterogeneous materials: A review
Bargmann, S., Klusemann, B., Markmann, J., Schnabel, J. E., Schneider, K., Soyarslan, C., & Wilmers, J. (2018) · Progress in Materials Science · doi:10.1016/j.pmatsci.2018.02.003 · Cited by 546
Phase Retrieval Using Alternating Minimization
Netrapalli, P., Jain, P., & Sanghavi, S. (2015) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2015.2448516 · Cited by 535
An assessment of the resolution limitation due to radiation-damage in X-ray diffraction microscopy
Howells, M. R., Beetz, T., Chapman, H. N., Cui, C., Holton, J. M., Jacobsen, C. J., Kirz, J., Lima, E., Marchesini, S., Miao, H., et al. (2009) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2008.10.008 · Cited by 524
Nanoscale Resolution in the Focal Plane of an Optical Microscope
Westphal, V., & Hell, S. W. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.143903 · Cited by 502
Coherent methods in the X-ray sciences
Nugent, K. A. (2010) · Advances in Physics · doi:10.1080/00018730903270926 · Cited by 476
Three-Dimensional Visualization of a Human Chromosome Using Coherent X-Ray Diffraction
Nishino, Y., Takahashi, Y., Imamoto, N., Ishikawa, T., & Maeshima, K. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.018101 · Cited by 306
Self-citationThree-Dimensional Imaging of Microstructure in Au Nanocrystals
Williams, G. J., Pfeifer, M. A., Vartanyants, I. A., & Robinson, I. K. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.175501 · Cited by 306
Imaging whole Escherichia coli bacteria by using single-particle x-ray diffraction
Miao, J., Hodgson, K. O., Ishikawa, T., Larabell, C. A., LeGros, M. A., & Nishino, Y. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.232691299 · Cited by 276
Self-citation
Metadata
- Authors
- Miao, J., Ishikawa, T., Johnson, B., Anderson, E. H., Lai, B., & Hodgson, K. O.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2002-08-06
- Volume
- 89
- Issue
- 8
- Pages
- 088303-088303
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1980207347
- Cited by
- 331
- References
- 10
- FWCI
- 21.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.