The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Synchronization of Distant Optical Clocks at the Femtosecond Level
Open accessAbstract
The use of optical clocks or oscillators in future ultraprecise navigation, gravitational sensing, coherent arrays, and relativity experiments will require time comparison and synchronization over terrestrial or satellite free-space links.Here, we demonstrate full unambiguous synchronization of two optical time scales across a free-space link.The time deviation between synchronized time scales is below 1 fs over durations from 0.1 to 6500 s, despite atmospheric turbulence and kilometer-scale path length variations.Over 2 days, the time wander is 40 fs peak to peak.Our approach relies on the two-way reciprocity of a single-spatial-mode optical link, valid to below 225 attoseconds across a turbulent 4-km path.This femtosecond level of time-frequency transfer should enable optical networks using state-of-the-art optical clocks or oscillators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Making optical atomic clocks more stable with 10−16-level laser stabilization
Jiang, Y. Y., Ludlow, A. D., Lemke, N. D., Fox, R. W., Sherman, J. A., Ma, L.-S., & Oates, C. W. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.313 · Cited by 462
Optical-Frequency Transfer over a Single-Span 1840 km Fiber Link
Droste, S., Ozimek, F., Udem, T., Predehl, K., Hänsch, T. W., Schnatz, H., Grosche, G., & Holzwarth, R. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.110801 · Cited by 315
Simultaneous remote transfer of accurate timing and optical frequency over a public fiber network
Lopez, O., Kanj, A., Pottie, P.-E., Rovera, D., Achkar, J., Chardonnet, C., Amy-Klein, A., & Santarelli, G. (2013) · Applied Physics B · doi:10.1007/s00340-012-5241-0 · Cited by 168
Robert, C., Conan, J.-M., & Wolf, P. (2016) · Physical Review A · doi:10.1103/physreva.93.033860 · Cited by 84
Müller, J., Soffel, M., & Klioner, S. A. (2008) · Journal of Geodesy · doi:10.1007/s00190-007-0168-7 · Cited by 82
Time and frequency comparisons using radiofrequency signals from satellites
Bauch, A. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.02.006 · Cited by 27
Research works printed but not linked: 35
- 10.1103/PhysRevLett.104.070802 · DOI · Paper page
- 10.1126/science.1240420 · DOI · Paper page
- 10.1038/nphoton.2015.5 · DOI · Paper page
- 10.1103/PhysRevA.77.033847 · DOI
- 10.1103/PhysRevA.79.053829 · DOI · Paper page
- 10.1364/OE.19.003471 · DOI
- 10.1038/nphoton.2012.217 · DOI · Paper page
- 10.1098/rsta.2011.0237 · DOI
- 10.1038/nphys3000 · DOI · Paper page
- 10.1140/epjst/e2009-01041-7 · DOI · Paper page
- 10.1007/s10686-008-9118-5 · DOI
- 10.1007/s10686-008-9126-5 · DOI
- 10.1063/1.2195297 · DOI
- 10.1126/science.1192720 · DOI · Paper page
- 10.1143/APEX.4.082203 · DOI
- 10.1038/nphys3137 · DOI · Paper page
- 10.1088/0026-1394/51/3/253 · DOI
- 10.5194/ars-9-1-2011 · DOI
- P. Delva, 2012, Proceedings of the European Frequency and Time Forum, EFTF 2012
- 10.1016/j.crhy.2015.05.002 · DOI
- 10.1103/PhysRevA.90.061802 · DOI
- 10.1088/0026-1394/49/6/772 · DOI
- 10.1088/0026-1394/50/2/133 · DOI · Paper page
- 10.1038/nphoton.2008.225 · DOI · Paper page
- 10.1364/OE.22.014904 · DOI
- 10.1109/MCS.2006.1580149 · DOI · Paper page
- B. Ning, 2014, Sci. Rep., 4, 5109, 10.1038/srep05109 · DOI
- 10.1364/OL.35.001479 · DOI
- 10.1038/nphoton.2013.69 · DOI · Paper page
- 10.1088/0026-1394/51/5/503 · DOI
- L. C. Andrews, 2005, Laser Beam Propagation through Random Media, Laser Beam Propagation through Random Media, 10.1117/3.626196 · DOI · Paper page
- 10.1103/PhysRevA.89.023805 · DOI · Paper page
- 10.1063/1.4928163 · DOI · Paper page
- 10.1109/5.84975 · DOI · Paper page
- L. C. Sinclair, 2016, Slow Light, Fast Light, and Opto-Atomic Precision Metrology, SPIE Proceedings Vol IX
Cited by
Frequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
Self-citationLim, J., Liang, W., Savchenkov, A. A., Matsko, A. B., Maleki, L., & Wong, C. W. (2019) · Light: Science & Applications · doi:10.1038/s41377-018-0109-7 · Cited by 329
JILA SrI optical lattice clock with uncertainty of 2.0 × 10 − 18
Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J. (2019) · Metrologia · doi:10.1088/1681-7575/ab4089 · Cited by 324
Riehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
Synchronization of clocks through 12 km of strongly turbulent air over a city
Sinclair, L. C., Swann, W. C., Bergeron, H., Baumann, E., Cermak, M., Coddington, I., Deschênes, J.-D., Giorgetta, F. R., Juarez, J. C., Khader, I., et al. (2016) · Applied Physics Letters · doi:10.1063/1.4963130 · Cited by 82
Self-citationDetermination of a high spatial resolution geopotential model using atomic clock comparisons
Lion, G., Panet, I., Wolf, P., Guerlin, C., Bize, S., & Delva, P. (2017) · Journal of Geodesy · doi:10.1007/s00190-016-0986-6 · Cited by 66
“2016) and free space optical links (Deschênes et al. 2016).”
BackgroundMethodInfluentialChronometric Geodesy: Methods and Applications
Delva, P., Denker, H., & Lion, G. (2019) · Fundamental Theories of Physics · doi:10.1007/978-3-030-11500-5_2 · Cited by 28
“bre as a medium for the propagation [108, 109, 75, 74], attaining spectacular stability and accuracy in the range 10 19 and below. However, phase coherent free space optical links are being developed [110, 111, 112, 113]. It is not clear yet if these techniques will be able to be as good as optical bre techniques, mai…”
BackgroundInfluential
Metadata
- Authors
- Deschênes, J.-D., Sinclair, L. C., Giorgetta, F. R., Swann, W. C., Baumann, E., Bergeron, H., Cermak, M., Coddington, I., & Newbury, N. R.
- Venue
- Physical Review X
- Publisher
- American Physical Society (APS)
- Published
- 2016-05-11
- Volume
- 6
- Issue
- 2
- ISSN
- 2160-3308 (ISSN-L)
- OpenAlex
- W2124016474
- Cited by
- 164
- References
- 8
- FWCI
- 8.26
- Type
- journal article
- Language
- en
- Open access
- gold
- Funders
- National Institute of Standards and Technology
- DARPA DSO PULSE
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.