Abstract
A new interconnection technique has been developed that allows versatile multiple strand connections between microsensors, sensor arrays, and chips designed for wire bonding. The new technique has been termed “Microflex interconnection” technique (MFI). Conventional wire bonding technique is commonly restricted to planar interconnects with a limited degree of freedom for placing microsystem components in hybrid assemblies. The MFI technique has overcome this limitation by interconnecting microsystem components through custom designed flexible substrates with embedded metallized conductors, pad arrays for integrated circuits’ assembly and substrate integrated electrodes. Standard CMOS components without additional pad metallization can be used. The integration density of the MFI technique corresponds to one of the flip-chip technology. Special advantages of the MFI technique are three-dimensional interconnects, the flexibility in design and shape, and easy visual inspection of alignment qualities. The method is especially suitable for small volumes of customer specified devices and biomedical implants because all materials used are biocompatible. Within this paper, the MFI technique is introduced, described in detail, and tested according to international standards. The evaluation of the electrical and mechanical properties of the interconnection sites exhibited promising results regarding stability and reliability. First applications in the biomedical field were presented on the example of a neural implant and a sensorized cardiac catheter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polyimides as biomaterials: preliminary biocompatibility testing
Richardson, R. R., Miller, J. A., & Reichert, W. M. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90183-3 · Cited by 302
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207 · cited 1×
“The substrate-integrated electrodes on the neural microimplants were used for recording of nerve signals and for electrical simulation of nerve fibers [5,6].”
MethodSelf-citationStieglitz, T., Beutel, H., & Meyer, J.-U. (1997) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)01494-5 · Cited by 125 · cited 1×
“Therefore, a microtechnology was developed for the fabrication of flexible microelectrode arrays with integrated flexible multichannel ribbon cables [3].”
MethodSelf-citationFlexible miniature ribbon cables for long‐term connection to implantable sensors
Hetke, J. F., Najafi, K., & Wise, K. D. (1990) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(90)87076-u · Cited by 33 · cited 1×
“Thermal compression bonding was used to connect silicon microelectrodes with flexible cables at small pitches [7], where both contact pads are patterned with a thin-film gold layer.”
MethodHistological Reaction to Polyimide Films in the Cochlea
Haggerty, H. S., & Lusted, H. S. (1989) · Acta Oto-Laryngologica · doi:10.3109/00016488909127474 · Cited by 31
Cited by
Giagka, V., & Serdijn, W. A. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0010-y · Cited by 58
Čvančara, P., Boretius, T., López-Álvarez, V. M., Maciejasz, P., Andreu, D., Raspopovic, S., Petrini, F., Micera, S., Granata, G., Fernandez, E., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9a9a · Cited by 58
“The electrode was attached to the interconnecting ceramic via the MFI technique [30].”
MethodSelf-citationHigh-density mapping of primate digit representations with a 1152-channel µECoG array
Kaiju, T., Inoue, M., Hirata, M., & Suzuki, T. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abe245 · Cited by 42
“Consequently, without redesigning the board, the number of electrodes can be increased by simply increasing the number of PCBs; even if a failure occurs in each PCB, it can be addressed by individual replacements.”
MethodInfluentialAn ASIC for Recording and Stimulation in Stacked Microchannel Neural Interfaces
Lancashire, H. T., Jiang, D., Demosthenous, A., & Donaldson, N. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2891284 · Cited by 15
Microchannel neural interface manufacture by stacking silicone and metal foil laminae
Lancashire, H. T., Vanhoestenberghe, A., Pendegrass, C. J., Ajam, Y. A., Magee, E., Donaldson, N., & Blunn, G. W. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/034001 · Cited by 13
“Interconnects between soft thin-films or metal foils and stiff substrates have been achieved by micro-rivet bonding [7, 32, 33], parallel gap welding, laser welding, soldering [34] and plasma bonding to glass substrates with gold bumps [35].”
Background
Metadata
- Authors
- Stieglitz, T., Beutel, H., & Meyer, J. U.
- Venue
- Journal of Intelligent Material Systems and Structures
- Publisher
- SAGE Publications
- Published
- 2000-06
- Volume
- 11
- Issue
- 6
- Pages
- 417-425
- ISSN
- 1045-389X (ISSN-L)
- 1530-8138
- OpenAlex
- W2047137201
- Cited by
- 67
- References
- 5
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: “Microflex”—A New Assembling Technique for Interconnects. https://app.cochat.ai/papers/10.1106/r7bv-511b-21rj-r2fa
- The paper
- Stieglitz, T., Beutel, H., & Meyer, J. U. (2000). “Microflex”—A New Assembling Technique for Interconnects. Journal of Intelligent Material Systems and Structures. https://doi.org/10.1106/r7bv-511b-21rj-r2fa
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.