ANKAphase: software for single-distance phase retrieval from inline X-ray phase-contrast radiographs
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
A computer program named ANKAphase is presented that processes X-ray inline phase-contrast radiographs by reconstructing the projected thickness of the object(s) imaged. The program uses a single-distance non-iterative phase-retrieval algorithm described by David Paganin et al.[(2002),J. Microsc.206, 33–40]. Allowing for non-negligible absorption in the sample, this method is strictly valid only for monochromatic illumination and single-material objects but tolerates deviations from these conditions, especially polychromaticity.ANKAphase is designed to be applied to tomography data (although it does not perform tomographic reconstruction itself). It can process series of images and perform flat-field and dark-field correction. Written in Java,ANKAphase has an intuitive graphical user interface and can be run either as a stand-alone application or as a plugin to ImageJ, a widely used scientific image-processing program. A description of ANKAphase is given and example applications are shown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical Recipes, The Art of Scientific Computing
Press, W. H., Flannery, B. P., Teukolsky, S. A., Vetterling, W. T., & Gould, H. (1987) · American Journal of Physics · doi:10.1119/1.14981 · Cited by 10,024
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object
Paganin, D., Mayo, S. C., Gureyev, T. E., Miller, P. R., & Wilkins, S. W. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01010.x · Cited by 2,062
Phase-contrast imaging using polychromatic hard X-rays
Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A., & Stevenson, A. W. (1996) · Nature · doi:10.1038/384335a0 · Cited by 1,766
Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S., & Schelokov, I. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146073 · Cited by 1,493
Cloetens, P., Ludwig, W., Baruchel, J., Van Dyck, D., Van Landuyt, J., Guigay, J. P., & Schlenker, M. (1999) · Applied Physics Letters · doi:10.1063/1.125225 · Cited by 1,078
Phase objects in synchrotron radiation hard x-ray imaging
Cloetens, P., Barrett, R., Baruchel, J., Guigay, J.-P., & Schlenker, M. (1996) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/29/1/023 · Cited by 853
Quantitative Phase Imaging Using Hard X Rays
Nugent, K. A., Gureyev, T. E., Cookson, D. F., Paganin, D., & Barnea, Z. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.2961 · Cited by 675
Labiche, J.-C., Mathon, O., Pascarelli, S., Newton, M. A., Ferre, G. G., Curfs, C., Vaughan, G., Homs, A., & Carreiras, D. F. (2007) · Review of Scientific Instruments · doi:10.1063/1.2783112 · Cited by 394
MicroComputed Tomography: Methodology and Applications
Stock, S. R. (2008) · Thammasat University Digital Collections · Cited by 336
X-ray computed microtomography (μCT) using synchrotron radiation (SR)
Bonse, U., & Busch, F. (1996) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(96)00011-9 · Cited by 304
BETZ, O., WEGST, U., WEIDE, D., HEETHOFF, M., HELFEN, L., LEE, W., & CLOETENS, P. (2007) · Journal of Microscopy · doi:10.1111/j.1365-2818.2007.01785.x · Cited by 277
Tracheal Respiration in Insects Visualized with Synchrotron X-ray Imaging
Westneat, M. W., Betz, O., Blob, R. W., Fezzaa, K., Cooper, W. J., & Lee, W.-K. (2003) · Science · doi:10.1126/science.1078008 · Cited by 248
Theory of quantitative phase-contrast computed tomography
Bronnikov, A. V. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.000472 · Cited by 195
Rack, A., Zabler, S., Müller, B. R., Riesemeier, H., Weidemann, G., Lange, A., Goebbels, J., Hentschel, M., & Görner, W. (2008) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2007.11.020 · Cited by 193
Self-citation2D and 3D X-ray phase retrieval of multi-material objects using a single defocus distance
Beltran, M. A., Paganin, D. M., Uesugi, K., & Kitchen, M. J. (2010) · Optics Express · doi:10.1364/oe.18.006423 · Cited by 187
Quantitative comparison of direct phase retrieval algorithms in in‐line phase tomography
Langer, M., Cloetens, P., Guigay, J., & Peyrin, F. (2008) · Medical Physics · doi:10.1118/1.2975224 · Cited by 179
The chitin crystallite in arthropod cuticle
Neville, A. C., Parry, D. A. D., & Woodhead-Galloway, J. (1976) · Journal of Cell Science · doi:10.1242/jcs.21.1.73 · Cited by 172
Implementation of a fast method for high resolution phase contrast tomography
Groso, A., Abela, R., & Stampanoni, M. (2006) · Optics Express · doi:10.1364/oe.14.008103 · Cited by 167
Pore3D: A software library for quantitative analysis of porous media
Brun, F., Mancini, L., Kasae, P., Favretto, S., Dreossi, D., & Tromba, G. (2010) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2010.02.063 · Cited by 159
Advances in Biological Structure, Function, and Physiology Using Synchrotron X-Ray Imaging
Westneat, M. W., Socha, J. J., & Lee, W.-K. (2008) · Annual Review of Physiology · doi:10.1146/annurev.physiol.70.113006.100434 · Cited by 156
The micro-imaging station of the TopoTomo beamline at the ANKA synchrotron light source
Rack, A., Weitkamp, T., Trabelsi, S. B., et al. (2009) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2009.04.002 · Cited by 106
Self-citationLinear algorithms for phase retrieval in the Fresnel region. 2. Partially coherent illumination
Gureyev, T. E., Nesterets, Y. I., Paganin, D. M., Pogany, A. P., & Wilkins, S. W. (2005) · Optics Communications · doi:10.1016/j.optcom.2005.09.072 · Cited by 100
Rack, A., García‐Moreno, F., Schmitt, C., Betz, O., Cecilia, A., Ershov, A., Rack, T., Banhart, J., & Zabler, S. (2010) · Journal of X-Ray Science and Technology · doi:10.3233/xst-2010-0273 · Cited by 77
Self-citationPhase contrast tomography: An alternative approach
Groso, A., Stampanoni, M., Abela, R., Schneider, P., Linga, S., & Müller, R. (2006) · Applied Physics Letters · doi:10.1063/1.2207221 · Cited by 76
3D images of paper obtained by phase-contrast X-ray microtomography: image quality and binarisation
Antoine, C., Nygård, P., Gregersen, Ø. W., Holmstad, R., Weitkamp, T., & Rau, C. (2002) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(02)01003-3 · Cited by 68
Self-citationPhase-contrast X-ray imaging with synchrotron radiation for materials science applications
Stevenson, A. W., Gureyev, T. E., Paganin, D. M., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(02)01557-4 · Cited by 63
Polychromatic cone-beam phase-contrast tomography
Myers, G. R., Mayo, S. C., Gureyev, T. E., et al. (2007) · Physical Review A · doi:10.1103/physreva.76.045804 · Cited by 55
Stiller, M., Rack, A., Zabler, S., Goebbels, J., Dalügge, O., Jonscher, S., & Knabe, C. (2008) · Bone · doi:10.1016/j.bone.2008.10.049 · Cited by 45
Self-citationNonlinear phase retrieval from single-distance radiograph
Moosmann, J. P., Hofmann, R., Bronnikov, A. V., & Baumbach, T. (2010) · Optics Express · doi:10.1364/oe.18.025771 · Cited by 37
Bremmer, H. (1952) · Physica · doi:10.1016/s0031-8914(52)80079-5 · Cited by 35
X-ray phase contrast tomography with a bending magnet source
Peele, A. G., Carlo, F. D., McMahon, P. J., Dhal, B. B., & Nugent, K. A. (2005) · Review of Scientific Instruments · doi:10.1063/1.2005447 · Cited by 34
Use of synchrotron tomography to image naturalistic anatomy in insects
Socha, J. J., & Carlo, F. D. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.795210 · Cited by 28
Cited by
Cnudde, V., & Boone, M. N. (2013) · Earth-Science Reviews · doi:10.1016/j.earscirev.2013.04.003 · Cited by 1,572
PITRE: software for phase-sensitive X-ray image processing and tomography reconstruction
Chen, R.-C., Dreossi, D., Mancini, L., Menk, R., Rigon, L., Xiao, T.-Q., & Longo, R. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512029731 · Cited by 279
X-Ray Tomography for Lithium Ion Battery Research: A Practical Guide
Pietsch, P., & Wood, V. (2017) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-070616-123957 · Cited by 255
In Vivo Time-Resolved Microtomography Reveals the Mechanics of the Blowfly Flight Motor
Walker, S. M., Schwyn, D. A., Mokso, R., Wicklein, M., Müller, T., Doube, M., Stampanoni, M., Krapp, H. G., & Taylor, G. K. (2014) · PLoS Biology · doi:10.1371/journal.pbio.1001823 · Cited by 182
“Phase retrieval was performed in a qualitative manner using the ANKAPhase implementation [38] single image phase retrieval algorithm under the assumption that the object consisted of a homogeneous soft tissue material [39].”
MethodAdvantages of phase retrieval for fast x-ray tomographic microscopy
Mokso, R., Marone, F., Irvine, S., Nyvlt, M., Schwyn, D., Mader, K., Taylor, G. K., Krapp, H. G., Skeren, M., & Stampanoni, M. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/49/494004 · Cited by 56
Metadata
- Authors
- Weitkamp, T., Haas, D., Wegrzynek, D., & Rack, A.
- Venue
- Journal of Synchrotron Radiation
- Published
- 2011-03-16
- Volume
- 18
- Issue
- 4
- Pages
- 617-629
- ISSN
- 0909-0495 (ISSN-L)
- OpenAlex
- W2018959018
- Cited by
- 278
- References
- 33
- FWCI
- 19.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.