User‐adaptive control of a magnetorheological prosthetic knee
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A magnetorheological knee prosthesis is presented that automatically adapts knee damping to the gait of the amputee using only local sensing of knee force, torque, and position. To assess the clinical effects of the user‐adaptive knee prosthesis, kinematic gait data were collected on four unilateral trans‐femoral amputees. Using the user‐adaptive knee and a conventional, non‐adaptive knee, gait kinematics were evaluated on both affected and unaffected sides. Results were compared to the kinematics of 12 age, weight and height matched normals. We find that the user‐adaptive knee successfully controls early stance damping, enabling amputee to undergo biologically‐realistic, early stance knee flexion. These results indicate that a user‐adaptive control scheme and local mechanical sensing are all that is required for amputees to walk with an increased level of biological realism compared to mechanically passive prosthetic systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216 · cited 1×
“The data were processed at 120 Hz with VICON Workstation (Oxford Metrics, UK) using the standard model of the lower limbs included with the software (Davis et al., 1991; Kadaba et al., 1990; Ramakrishnan et al., 1987).”
MethodA gait analysis data collection and reduction technique
Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R. (1991) · Human Movement Science · doi:10.1016/0167-9457(91)90046-z · Cited by 3,086 · cited 1×
“The data were processed at 120 Hz with VICON Workstation (Oxford Metrics, UK) using the standard model of the lower limbs included with the software (Davis et al., 1991; Kadaba et al., 1990; Ramakrishnan et al., 1987).”
MethodControl of Movement for the Physically Disabled
(2000) · Springer eBooks · doi:10.1007/978-1-4471-0433-9 · Cited by 182
Peeraer, L., Aeyels, B., & Van der Perre, G. (1990) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(90)90037-n · Cited by 87
Myoelectric Pattern Recognition for Use in the Volitional Control of Above-Knee Prostheses
Myers, D. R., & Moskowitz, G. D. (1981) · IEEE Transactions on Systems Man and Cybernetics · doi:10.1109/tsmc.1981.4308676 · Cited by 27
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“Many groups have successfully implemented FSCs using different numbers of activities and states with a wide variety of devices [2,3,14,24,41,44,107-109,114,117, 118,121,123,124,134,137-139,143,150,163,171-186].”
A Strategy for Identifying Locomotion Modes Using Surface Electromyography
Huang, H., Kuiken, T. A., & Lipschutz, R. D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2003293 · Cited by 512
Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation
Park, Y.-L., Chen, B.-R., Pérez-Arancibia, N. O., Young, D., Stirling, L., Wood, R. J., Goldfield, E. C., & Nagpal, R. (2014) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/1/016007 · Cited by 497
“While active devices require relatively complicated systems compared to passive braces, with appropriate control, they not only can provide higher independence, as shown with robotic prosthetic legs [12, 13], but also can be used for re-educating the neuro-motor system [14], with previous work showing the efficacy of…”
BackgroundPowered ankle-foot prosthesis to assist level-ground and stair-descent gaits
Au, S., Berniker, M., & Herr, H. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.006 · Cited by 487
Self-citationA QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATION
WALSH, C. J., ENDO, K., & HERR, H. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001126 · Cited by 427
Self-citationAdvances in wearable technology and applications in physical medicine and rehabilitation
Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-2 · Cited by 385
A Clinical Comparison of Variable-Damping and Mechanically Passive Prosthetic Knee Devices
Johansson, J. L., Sherrill, D. M., Riley, P. O., Bonato, P., & Herr, H. (2005) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/01.phm.0000174665.74933.0b · Cited by 302
Self-citationAu, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
Self-citationLock Your Robot: A Review of Locking Devices in Robotics
Plooij, M., Mathijssen, G., Cherelle, P., Lefeber, D., & Vanderborght, B. (2015) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2381368 · Cited by 165
“[71], and the prosthesis of Herr and Wilkenfeld [72].”
Bio-inspired active soft orthotic device for ankle foot pathologies
Park, Y.-L., Chen, B.-R., Young, D., Stirling, L., Wood, R. J., Goldfield, E., & Nagpal, R. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6094933 · Cited by 130
“While active devices require relatively complicated systems compared to passive braces, with appropriate control, they can provide higher independence, as seen with active prosthetic legs [6], [14], [16], [21].”
Background
Metadata
- Authors
- Herr, H., & Wilkenfeld, A.
- Venue
- Industrial Robot: An International Journal
- Publisher
- Emerald
- Published
- 2003-02-01
- Volume
- 30
- Issue
- 1
- Pages
- 42-55
- ISSN
- 0143-991X (ISSN-L)
- OpenAlex
- W2077458356
- Cited by
- 293
- References
- 5
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.