Separation of action potentials in multiunit intrafascicular recordings
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Classification of action potentials in multiunit recordings was based on the use of various types of features to uniquely characterize action potentials from different cells. We compared classification results obtained using three types of descriptive features: digitized data points, amplitude and duration (time domain) parameters, and fast Fourier transform (FFT) coefficients. Digitized data points used as descriptive features provided good classification success and required minimal computation. Time-domain features gave comparable results but required more computation. FFT coefficients were less effective than the other features. As the signal-to-noise ratio of the recordings increased, smaller differences in feature values could be discriminated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172
Self-citationAn intrafascicular electrode for recording of action potentials in peripheral nerves
Malagodi, M. S., Horch, K. W., & Schoenberg, A. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02368058 · Cited by 107
Self-citationInformation contained in sensory nerve recordings made with intrafascicular electrodes
Goodall, E. V., Lefurge, T. M., & Horch, K. W. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83604 · Cited by 63
Self-citation
Research works printed but not linked: 20
- 10.1016/0165-0270(83)90078-X · doi:10.1016/0165-0270(83)90078-x
- 10.1016/0010-4809(78)90003-4 · doi:10.1016/0010-4809(78)90003-4
- 10.1109/TBME.1970.4502714 · doi:10.1109/tbme.1970.4502714
- 10.1016/0165-0270(88)90132-X · doi:10.1016/0165-0270(88)90132-x
- 10.1016/0165-0270(84)90009-8 · DOI
- 10.1016/0165-0270(84)90042-6 · DOI
- 10.1016/0010-4809(69)90009-3 · doi:10.1016/0010-4809(69)90009-3
- 10.1016/0013-4694(65)90029-5 · doi:10.1016/0013-4694(65)90029-5
- vallbo, 1984, Properties of cutaneous mechanoreceptors in the human hand related to touch sensation, Human Neurobiol, 3, 3
- 10.1109/TBME.1981.324679 · doi:10.1109/tbme.1981.324679
- 10.1016/0013-4694(70)90011-8 · doi:10.1016/0013-4694(70)90011-8
- 10.1111/1523-1747.ep12497887 · DOI · Paper page
- 10.1109/TBME.1980.326666 · doi:10.1109/tbme.1980.326666
- 10.1109/TBME.1979.326403 · doi:10.1109/tbme.1979.326403
- 10.1016/0006-8993(79)90397-4 · DOI
- de n�, 1947, A study of nerve physiology. XVI. Analysis of the distribution of the action currents of nerve in volume conductors, Studies Rockfeller Inst Med Res, 132, 384
- 10.1016/0013-4694(79)90219-0 · DOI
- 10.1016/0165-0270(86)90067-1 · DOI
- 10.1109/TBME.1982.324870 · DOI
- 10.1007/BF02477041 · doi:10.1007/bf02477041
Cited by
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Lago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227
“Acute animal studies have shown that LIFEs can provide topologically selective stimulation [3] as well as recordings from a limited number of nerve fibers [ 4 ], [5].”
BackgroundMicera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
Lawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K., & Horch, K. W. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.831491 · Cited by 106
Self-citation
Metadata
- Authors
- Goodall, E. V., & Horch, K. W.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1992-03
- Volume
- 39
- Issue
- 3
- Pages
- 289-295
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2095989732
- Cited by
- 55
- References
- 3
- FWCI
- 0.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Separation of action potentials in multiunit intrafascicular recordings. https://app.cochat.ai/papers/10.1109/10.125014
- The paper
- Goodall, E. V., & Horch, K. W. (1992). Separation of action potentials in multiunit intrafascicular recordings. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.125014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.