The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Scaling limitations of silicon multichannel recording probes
Abstract
This paper describes the scaling limitations of multichannel recording probes fabricated for use in neurophysiology using silicon integrated circuit technologies. Scaled silicon probe substrates 8 microns thick and 16 microns wide can be fabricated using boron etch-stop techniques. Theoretical expressions for calculating the thickness and width of silicon substrates have been derived and agree closely with experimental results. The effects of scaling probe dimensions on its strength and stiffness are described. The probe shank dimensions can be designed to vary the strength and stiffness for different applications. The scaled silicon substrates have a fracture stress of about 2 x 10(10) dyn/cm2, which is about six times that of bulk silicon, and are strong and very flexible. Scaling the feature sizes of recording electrode arrays down to 1 micron is possible with less than 1 percent electrical crosstalk between channels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Strength characterization of silicon microprobes in neurophysiological tissues
Najafi, K., & Hetke, J. F. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55638 · Cited by 146
Self-citation
Research works printed but not linked: 12
- timoshenko, 1968, Elements of Strength of Materials
- 10.1016/0001-6160(57)90164-5 · DOI · Paper page
- plonsey, 1969, Bioelectric Phenomena, 205
- 10.1149/1.2113747 · doi:10.1149/1.2113747
- 10.1109/10.7273 · DOI · Paper page
- 10.1149/1.2134326 · doi:10.1149/1.2134326
- 10.1109/JRPROC.1959.287156 · DOI · Paper page
- 10.1147/rd.93.0179 · doi:10.1147/rd.93.0179
- 10.1149/1.2412239 · doi:10.1149/1.2412239
- 10.1109/JSSC.1986.1052646 · DOI · Paper page
- 10.1109/T-ED.1985.22102 · DOI · Paper page
- 10.1002/j.1538-7305.1980.tb02992.x · doi:10.1002/j.1538-7305.1980.tb02992.x
Cited by
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Self-citationA Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Metadata
- Authors
- Najafi, K., Ji, J., & Wise, K. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1990
- Volume
- 37
- Issue
- 1
- Pages
- 1-11
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2055554935
- Cited by
- 163
- References
- 1
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Scaling limitations of silicon multichannel recording probes. https://app.cochat.ai/papers/10.1109/10.43605
- The paper
- Najafi, K., Ji, J., & Wise, K. D. (1990). Scaling limitations of silicon multichannel recording probes. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.43605
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.