The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Recursive MUSIC: A framework for EEG and MEG source localization
Abstract
The multiple signal classification (MUSIC) algorithm can be used to locate multiple asynchronous dipolar sources from electroencephalography (EEG) and magnetoencephalography (MEG) data. The algorithm scans a single-dipole model through a three-dimensional (3-D) head volume and computes projections onto an estimated signal subspace. To locate the sources, the user must search the head volume for multiple local peaks in the projection metric. This task is time consuming and subjective. Here, we describe an extension of this approach which we refer to as recursive MUSIC (R-MUSIC). This new procedure automatically extracts the locations of the sources through a recursive use of subspace projections. The new method is also able to locate synchronous sources through the use of a spatio-temporal independent topographies (IT) model. This model defines a source as one or more nonrotating dipoles with a single time course. Within this framework, we are able to locate fixed, rotating, and synchronous dipoles. The recursive subspace projection procedure that we introduce here uses the metric of canonical or subspace correlations as a multidimensional form of correlation analysis between the model subspace and the data subspace. By recursively computing subspace correlations, we build up a model for the sources which account for a given set of data. We demonstrate here how R-MUSIC can easily extract multiple asynchronous dipolar sources that are difficult to find using the original MUSIC scan. We then demonstrate R-MUSIC applied to the more general IT model and show results for combinations of fixed, rotating, and synchronous dipoles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple emitter location and signal parameter estimation
Schmidt, R. (1986) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1986.1143830 · Cited by 14,718
Two decades of array signal processing research: the parametric approach
Krim, H., & Viberg, M. (1996) · IEEE Signal Processing Magazine · doi:10.1109/79.526899 · Cited by 4,719
The Differentiation of Pseudo-Inverses and Nonlinear Least Squares Problems Whose Variables Separate
Golub, G. H., & Pereyra, V. (1973) · SIAM Journal on Numerical Analysis · doi:10.1137/0710036 · Cited by 1,430
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Self-citationMaximum likelihood methods for direction-of-arrival estimation
Stoica, P., & Sharman, K. C. (1990) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/29.57542 · Cited by 908
GOLUBf, G. H., & Pereyra, V. L. (1973) · Cited by 732
Sensor array processing based on subspace fitting
Viberg, M., & Ottersten, B. (1991) · IEEE Transactions on Signal Processing · doi:10.1109/78.80966 · Cited by 705
Two bilateral sources of the late AEP as identified by a spatio-temporal dipole model
Scherg, M., & Von Cramon, D. (1985) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(85)90033-4 · Cited by 683
Fundamentals if dipole source potential analysis
Scherg, M. (1990) · Max Planck Institute for Plasma Physics · Cited by 530
Detection and estimation in sensor arrays using weighted subspace fitting
Viberg, M., Ottersten, B., & Kailath, T. (1991) · IEEE Transactions on Signal Processing · doi:10.1109/78.97999 · Cited by 512
Cited by
MNE software for processing MEG and EEG data
Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.027 · Cited by 1,951
Baillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Self-citationMichel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Review on solving the inverse problem in EEG source analysis
Grech, R., Cassar, T., Muscat, J., Camilleri, K. P., Fabri, S. G., Zervakis, M., Xanthopoulos, P., Sakkalis, V., & Vanrumste, B. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-25 · Cited by 1,193
Separable nonlinear least squares: the variable projection method and its applications
Golub, G., & Pereyra, V. (2003) · Inverse Problems · doi:10.1088/0266-5611/19/2/201 · Cited by 760
Toward a quantitative description of large-scale neocortical dynamic function and EEG
Nunez, P. L. (2000) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00003253 · Cited by 467
Linear and Nonlinear Current Density Reconstructions
Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00006 · Cited by 436
Source localization using recursively applied and projected (RAP) MUSIC
Mosher, J. C., & Leahy, R. M. (1999) · IEEE Transactions on Signal Processing · doi:10.1109/78.740118 · Cited by 398
Self-citationA study of dipole localization accuracy for MEG and EEG using a human skull phantom
Leahy, R. M., Mosher, J. C., Spencer, M. E., Huang, M. X., & Lewine, J. D. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00057-1 · Cited by 383
Self-citationEEG source localization: Sensor density and head surface coverage
Song, J., Davey, C., Poulsen, C., Luu, P., Turovets, S., Anderson, E., Li, K., & Tucker, D. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.08.015 · Cited by 356
Mapping human brain function with MEG and EEG: methods and validation
Darvas, F., Pantazis, D., Kucukaltun-Yildirim, E., & Leahy, R. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.014 · Cited by 310
Self-citationBemis, D. K., & Pylkkänen, L. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.5003-10.2011 · Cited by 277
Dien, J., Spencer, K. M., & Donchin, E. (2003) · Cognitive Brain Research · doi:10.1016/s0926-6410(03)00188-5 · Cited by 262
Ossadtchi, A., Baillet, S., Mosher, J. C., Thyerlei, D., Sutherling, W., & Leahy, R. M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.10.036 · Cited by 104
Self-citationPaired MEG data set source localization using recursively applied and projected (RAP) MUSIC
Ermer, J. J., Mosher, J. C., Huang, M., & Leahy, R. M. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867959 · Cited by 64
Self-citationMATTOUT, J., PELEGRINIISSAC, M., GARNERO, L., & BENALI, H. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.026 · Cited by 52
Electrophysiological Mapping and Neuroimaging
He, B., & Ding, L. (2013) · Neural Engineering · doi:10.1007/978-1-4614-5227-0_12 · Cited by 26
Three-Dimensional Imaging of Complex Neural Activation in Humans From EEG
Ding, L., Zhang, N., Chen, W., & He, B. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2020438 · Cited by 4
“The MUSIC estimator normalizes the projection against the Frobenius norm of the gain vector, and finally, has the expression as JMUSIC(r, q) = ‖PnA(r, q)‖(2)F /‖A(r, q)‖(2)F (see [28] for details).”
BackgroundMethod
Metadata
- Authors
- Mosher, J. C., & Leahy, R. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1998
- Volume
- 45
- Issue
- 11
- Pages
- 1342-1354
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2159835457
- Cited by
- 362
- References
- 25
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.