Combined MEG and EEG source imaging by minimization of mutual information
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Though very frequently assumed, the necessity to operate a joint processing of simultaneous magnetoencephalography (MEG) and electroencephalography (EEG) recordings for functional brain imaging has never been clearly demonstrated. However, the very last generation of MEG instruments allows the simultaneous recording of brain magnetic fields and electrical potentials on the scalp. But the general fear regarding the fusion between MEG and EEG data is that the drawbacks from one modality will systematically spoil the performances of the other one without any consequent improvement. This is the case for instance for the estimation of deeper or radial sources with MEG. In this paper, we propose a method for a cooperative processing of MEG and EEG in a distributed source model. First, the evaluation of the respective performances of each modality for the estimation of every dipole in the source pattern is made using a conditional entropy criterion. Then, the algorithm operates a preprocessing of the MEG and EEG gain matrices which minimizes the mutual information between these two transfer functions, by a selective weighting of the MEG and EEG lead fields. This new combined EEG/MEG modality brings major improvements to the localization of active sources, together with reduced sensitivity to perturbations on data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 1×
“MEG, however, fails to locate deeper cortical sources because of the rapid fall of the magnetic field with depth [12].”
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 1×
“From these pseudoimages, it is possible to compute a joint histogram where (respectively, ) can take all the values of the rescaled (respectively, ) matrix [37].”
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869 · cited 6×
“3) Normalization of the resulting lead fields: this is a scaling step that contributes to the recovery of sources with weak lead fields norms [10], [16].”
InfluentialDale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003 · cited 3×
“To go further into the refinement of the source model, dipoles may be constrained on the surface of the cortex—maybe on some restricted cortical regions—with orientations perpendicular to the cortical surface [4], [5], [18], [26].”
Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm
Gorodnitsky, I. F., George, J. S., & Rao, B. D. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00107-a · Cited by 567
Selective minimum-norm solution of the biomagnetic inverse problem
Matsuura, K., & Okabe, Y. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.387200 · Cited by 243 · cited 1×
“In this latter case, one can choose priors in terms to the L1 norm of the source amplitudes that can avoid some of the smoothing properties of the L2 norm priors [41], [42].”
Probabilistic reconstruction of multiple sources in the bioelectromagnetic inverse problem
Greenblatt, R. E. (1993) · Inverse Problems · doi:10.1088/0266-5611/9/2/008 · Cited by 48
Cited by
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
Baillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Self-citationNonlinear multivariate analysis of neurophysiological signals
Pereda, E., Quiroga, R. Q., & Bhattacharya, J. (2005) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2005.10.003 · Cited by 1,076
Magnetoencephalography for Brain Electrophysiology and Imaging
Baillet, S. (2017) · Nature Neuroscience · doi:10.1038/nn.4504 · Cited by 992
Self-citationOptical tomography: forward and inverse problems
Arridge, S. R., & Schotland, J. C. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123010 · Cited by 625
Modalities, Modes, and Models in Functional Neuroimaging
Friston, K. J. (2009) · Science · doi:10.1126/science.1174521 · Cited by 489
A Quantitative Assessment of the Sensitivity of Whole-Head MEG to Activity in the Adult Human Cortex
Hillebrand, A., & Barnes, G. R. (2002) · NeuroImage · doi:10.1006/nimg.2002.1102 · Cited by 428
Barkley, G. L., & Baumgartner, C. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200305000-00002 · Cited by 202
“Some authors concluded that both techniques were complementary, and the combination of both techniques yielded information not available from either technique alone (Baillet et al., 1999; Baillet et al., 2002; Fuchs et al., 1998b).”
BackgroundQuantification of the benefit from integrating MEG and EEG data in minimum ℓ2-norm estimation
Molins, A., Stufflebeam, S. M., Brown, E. N., & Hämäläinen, M. S. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.064 · Cited by 192
“…characteristics of EEG and MEG, several authors have proposed methods for integrating both modalities, either in sequential steps as in Cohen and Cuffin (1987), Huang et al. (2007), or by combined analysis as in Babiloni et al. (2001, 2004), Baillet et al. (1999), Huizenga et al. (2001).”
Phillips, C., Rugg, M. D., & Friston, K. J. (2002) · NeuroImage · doi:10.1006/nimg.2002.1143 · Cited by 191
“When both EEG and MEG data are available simultaneously, they should be combined and used simultaneously to solve the source localization problem (Fuchs et al., 1998; Baillet et al., 1999 ) as the two kinds of data contain complementary information.”
MethodA multi-subject, multi-modal human neuroimaging dataset
Wakeman, D. G., & Henson, R. N. (2015) · Scientific Data · doi:10.1038/sdata.2015.1 · Cited by 190
IFCN-endorsed practical guidelines for clinical magnetoencephalography (MEG)
Hari, R., Baillet, S., Barnes, G., Burgess, R., Forss, N., Gross, J., Hämäläinen, M., Jensen, O., Kakigi, R., Mauguière, F., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.03.042 · Cited by 167
“042 When MEG and EEG are recorded simultaneously, the fusion of the two data sets provides a more complete picture of the brain’s neural activity (Baillet et al., 1999).”
BackgroundSelf-citationWearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography
Boto, E., Seedat, Z. A., Holmes, N., Leggett, J., Hill, R. M., Roberts, G., Shah, V., Fromhold, T. M., Mullinger, K. J., Tierney, T. M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116099 · Cited by 136
Ibanez, A., Cetkovich, M., Petroni, A., Urquina, H., Baez, S., Gonzalez-Gadea, M. L., Kamienkowski, J. E., Torralva, T., Torrente, F., Strejilevich, S., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037306 · Cited by 73
MATTOUT, J., PELEGRINIISSAC, M., GARNERO, L., & BENALI, H. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.026 · Cited by 52
Self-citation
Metadata
- Authors
- Baillet, S., Garnero, L., Marin, G., & Hugonin, J.-P.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1999-05
- Volume
- 46
- Issue
- 5
- Pages
- 522-534
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2155974276
- Cited by
- 113
- References
- 7
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.