Resolution of the epiretinal prosthesis is not limited by electrode size

Open access
Behrend, Matthew R., Ahuja, Ashish K., Humayun, Mark S., Chow, Robert H., Weiland, James D.·2011·IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

Epiretinal prostheses for the blind bypass diseased photosensitive cells in the retina, directly stimulating retinal neurons electrically and evoking signals that are relayed to the brain. Current clinical implants have few electrodes and provide limited visual acuity. Acuity may be improved by identifying electrode array design features and operational details that enhance or interfere with visual percept formation. We labeled all retinal ganglion cells in whole mount retina with a calcium reporter and then measured the number and pattern of cells responding, over a range of electrode diameters and stimulus durations. Span of the response scaled with electrode diameter for electrodes 60 μm and larger. Short stimulation pulse widths selectively activated cells nearest the electrode. Our measurements in the salamander retina suggest that the spatial resolution is 150 μm, which on a human retina is equivalent to 0.55(°) of human visual field and corresponding Snellen acuity of 20/660. Reading large print could be possible with such a prosthesis.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2011.2140132

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Electrode size is not the only limiting factor, and further reducing the electrode diameter might not correlate to better resolution.

    “However, the electrode size is not the only limiting factor, and further reducing the electrode diameter might not correlate to better resolution [142].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Behrend, M. R., Ahuja, A. K., Humayun, M. S., Chow, R. H., & Weiland, J. D.
Affiliations
University of Southern California (US)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2011-08
Volume
19
Issue
4
Pages
436-442
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2142922154
Cited by
102
References
40
Citations by year
2026: 4 · 2025: 5 · 2024: 2 · 2023: 3 · 2022: 10 · 2021: 9 · 2020: 9 · 2019: 7 · 2018: 9 · 2017: 5 · 2016: 9 · 2015: 10 · 2014: 6 · 2013: 11 · 2012: 2
FWCI
2.52
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Eye Institute (R29EY011888)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinal Development and Disorders
Keywords
epiretinal prosthesis, retinal prosthesis, electrode size, spatial resolution, retinal ganglion cells, calcium imaging, salamander retina, visual acuity, retinal stimulation
MeSH terms
Algorithms, Animals, Electric Stimulation, Electrodes, Gels, Prosthesis Design, Retina, Retinal Ganglion Cells, Sensory Thresholds, Caudata, Urodela, Vision, Ocular, Visual Acuity, Visual Prosthesis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review