Resolution of the epiretinal prosthesis is not limited by electrode size
Open accessAbstract
Epiretinal prostheses for the blind bypass diseased photosensitive cells in the retina, directly stimulating retinal neurons electrically and evoking signals that are relayed to the brain. Current clinical implants have few electrodes and provide limited visual acuity. Acuity may be improved by identifying electrode array design features and operational details that enhance or interfere with visual percept formation. We labeled all retinal ganglion cells in whole mount retina with a calcium reporter and then measured the number and pattern of cells responding, over a range of electrode diameters and stimulus durations. Span of the response scaled with electrode diameter for electrodes 60 μm and larger. Short stimulation pulse widths selectively activated cells nearest the electrode. Our measurements in the salamander retina suggest that the spatial resolution is 150 μm, which on a human retina is equivalent to 0.55(°) of human visual field and corresponding Snellen acuity of 20/660. Reading large print could be possible with such a prosthesis.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Electrode size is not the only limiting factor, and further reducing the electrode diameter might not correlate to better resolution.
“However, the electrode size is not the only limiting factor, and further reducing the electrode diameter might not correlate to better resolution [142].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [142]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · see citing works
Resistance for Flow of Current to a Disk
Newman, J. S. (1966) · Journal of The Electrochemical Society · doi:10.1149/1.2424003 · Cited by 724 · see citing works
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708 · see citing works
Holladay, J. T. (2004) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2004.01.014 · Cited by 688 · see citing works
Rapid Neural Coding in the Retina with Relative Spike Latencies
Gollisch, T., & Meister, M. (2008) · Science · doi:10.1126/science.1149639 · Cited by 663 · see citing works
Reorganization of Retinotopic Cortical Maps in Adult Mammals After Lesions of the Retina
Kaas, J. H., Krubitzer, L. A., Chino, Y. M., Langston, A., Polley, E. H., & Blair, N. P. (1990) · Science · doi:10.1126/science.2326637 · Cited by 647 · see citing works
Preservation of the Inner Retina in Retinitis Pigmentosa
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 644 · see citing works
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · see citing works
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G. F., Piyathaisere, D. V., O’Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 425 · see citing works
Self-citationInformation Processing in the Primate Retina: Circuitry and Coding
Field, G. D., & Chichilnisky, E. J. (2007) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.30.051606.094252 · Cited by 364 · see citing works
Rose, T. L., & Robblee, L. S. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.61038 · Cited by 359 · see citing works
Electrical Stimulation of Mammalian Retinal Ganglion Cells With Multielectrode Arrays
Sekirnjak, C., Hottowy, P., Sher, A., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01168.2005 · Cited by 336 · see citing works
Neuronal diversity in the retina
Masland, R. H. (2001) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(00)00230-0 · Cited by 320 · see citing works
Non-linear projection of the retinal image in a wide-angle schematic eye.
Drasdo, N., & Fowler, C. W. (1974) · British Journal of Ophthalmology · doi:10.1136/bjo.58.8.709 · Cited by 306 · see citing works
Litke, A. M., Bezayiff, N., Chichilnisky, E. J., Cunningham, W. R., Dąbrowski, W., Grillo, A. A., Grivich, M., Gryboś, P., Hottowy, P., Kachiguine, S., et al. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.832706 · Cited by 279 · see citing works
Gross, G., Wen, W. Y., & Lin, J. W. (1985) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(85)90105-0 · Cited by 257 · see citing works
Primate retina: cell types, circuits and color opponency
Dacey, D. M. (1999) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(98)00013-5 · Cited by 233 · see citing works
Recording spikes from a large fraction of the ganglion cells in a retinal patch
Segev, R., Goodhouse, J., Puchalla, J., & Berry, M. J. (2004) · Nature Neuroscience · doi:10.1038/nn1323 · Cited by 221 · see citing works
A Method for Generating Precise Temporal Patterns of Retinal Spiking Using Prosthetic Stimulation
Fried, S. I., Hsueh, H.-A., & Werblin, F. S. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00849.2005 · Cited by 212 · see citing works
Axonal Sodium-Channel Bands Shape the Response to Electric Stimulation in Retinal Ganglion Cells
Fried, S. I., Lasker, A., Desai, N. J., Eddington, D. K., & Rizzo, J. F. (2009) · Journal of Neurophysiology · doi:10.1152/jn.91081.2008 · Cited by 206 · see citing works
Factors affecting perceptual thresholds in epiretinal prostheses
de Balthasar, C., Patel, S., Roy, A., Freda, R., Greenwald, S., Horsager, A., Mahadevappa, M., Yanai, D., McMahon, M. J., Humayun, M. S., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0696 · Cited by 204 · see citing works
Self-citationHigh-Resolution Electrical Stimulation of Primate Retina for Epiretinal Implant Design
Sekirnjak, C., Hottowy, P., Sher, A., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2008) · Journal of Neuroscience · doi:10.1523/jneurosci.5138-07.2008 · Cited by 195 · see citing works
Multi-electrode stimulation and recording in the isolated retina
Grumet, A., Wyatt, J. L., & Rizzo, J. F. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00246-6 · Cited by 167 · see citing works
Morin, F., Takamura, Y., & Tamiya, E. (2005) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.100.131 · Cited by 166 · see citing works
Visually Guided Performance of Simple Tasks Using Simulated Prosthetic Vision
Hayes, J. S., Yin, V. T., Piyathaisere, D. V., Weiland, J. D., Humayun, M. S., & Dagnelie, G. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07309.x · Cited by 162 · see citing works
Self-citationJensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1018 · Cited by 159 · see citing works
Selective Activation of Neuronal Targets With Sinusoidal Electric Stimulation
Freeman, D. K., Eddington, D. K., Rizzo, J. F., & Fried, S. I. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00551.2010 · Cited by 149 · see citing works
Feasibility Study of a Retinal Prosthesis
Caspi, A. (2009) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2009.20 · Cited by 149 · see citing works
Jensen, R. J., Rizzo, J. F., Ziv, O. R., Grumet, A., & Wyatt, J. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1041 · Cited by 145 · see citing works
Massey, S. C., & Miller, R. F. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp017353 · Cited by 107 · see citing works
Visual resolution with retinal implants estimated from recordings in cat visual cortex
Eckhorn, R., Wilms, M., Schanze, T., Eger, M., Hesse, L., Eysel, U. T., Kisvárday, Z. F., Zrenner, E., Gekeler, F., Schwahn, H., et al. (2006) · Vision Research · doi:10.1016/j.visres.2006.01.034 · Cited by 94 · see citing works
Management of Hereditary Retinal Degenerations
Sharma, R., Sc, L. M., & Ehinger, B. (1999) · Survey of Ophthalmology · doi:10.1016/s0039-6257(99)00006-5 · Cited by 85 · see citing works
Laminar profile of resistivity in frog retina
Karwoski, C. J., Frambach, D. A., & Proenza, L. M. (1985) · Journal of Neurophysiology · doi:10.1152/jn.1985.54.6.1607 · Cited by 84 · see citing works
Suesserman, M. F., Spelman, F. A., & Rubinstein, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.81558 · Cited by 83 · see citing works
Inner Retinal Mechanisms Engaged by Retinal Electrical Stimulation
Margalit, E., & Thoreson, W. B. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-1093 · Cited by 81 · see citing works
Potts, A. M., & Inoue, J. (1969) · PubMed · Cited by 75 · see citing works
Retinal prosthesis phosphene shape analysis
Nanduri, D., Humayun, M. S., Greenberg, R. J., McMahon, M. J., & Weiland, J. D. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4649524 · Cited by 74 · see citing works
Self-citationSite of action potential initiation in amphibian retinal ganglion cells
Carras, P. L., Coleman, P. A., & Miller, R. F. (1992) · Journal of Neurophysiology · doi:10.1152/jn.1992.67.2.292 · Cited by 54 · see citing works
Selective labeling of retinal ganglion cells with calcium indicators by retrograde loading in vitro
Behrend, M. R., Ahuja, A., Humayun, M. S., Weiland, J. D., & Chow, R. H.-P. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.01.019 · Cited by 35 · see citing works
Self-citationDynamic Current Density of the Disk Electrode Double-Layer
Behrend, M. R., Ahuja, A., & Weiland, J. D. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.915723 · Cited by 22 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351 · see citing works
Photovoltaic restoration of sight with high visual acuity
Lorach, H., Goetz, G., Smith, R., Lei, X., Mandel, Y., Kamins, T. I., Mathieson, K., Huie, P., Harris, J. S., Sher, A., et al. (2015) · Nature Medicine · doi:10.1038/nm.3851 · Cited by 341 · see citing works
High-resolution CMOS MEA platform to study neurons at subcellular, cellular, and network levels
Müller, J., Ballini, M., Livi, P., Chen, Y., Radivojević, M., Shadmani, A., Viswam, V., Jones, I. L., Michele, F., Diggelmann, R., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00133a · Cited by 329 · see citing works
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272 · see citing works
Self-citationPhotovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration
Palanker, D., Le Mer, Y., Mohand-Said, S., Muqit, M., & Sahel, J. A. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2020.02.024 · Cited by 227 · see citing works
The functional performance of the Argus II retinal prosthesis
Stronks, H. C., & Dagnelie, G. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.862494 · Cited by 189 · see citing works
Design and validation of a foldable and photovoltaic wide-field epiretinal prosthesis
Ferlauto, L., Airaghi Leccardi, M. J. I., Chenais, N. A. L., Gilliéron, S. C. A., Vagni, P., Bevilacqua, M., Wolfensberger, T. J., Sivula, K., & Ghezzi, D. (2018) · Nature Communications · doi:10.1038/s41467-018-03386-7 · Cited by 183 · see citing works
Improving the spatial resolution of epiretinal implants by increasing stimulus pulse duration
Weitz, A. C., Nanduri, D., Behrend, M. R., Gonzalez-Calle, A., Greenberg, R. J., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac4877 · Cited by 154 · see citing works
Self-citationImplantable microcoils for intracortical magnetic stimulation
Lee, S. W., Fallegger, F., Casse, B. D. F., & Fried, S. I. (2016) · Science Advances · doi:10.1126/sciadv.1600889 · Cited by 151 · see citing works
Factors Affecting Perceptual Threshold in Argus II Retinal Prosthesis Subjects
Ahuja, A. K., Yeoh, J., Dorn, J. D., Caspi, A., Wuyyuru, V., McMahon, M. J., Humayun, M. S., Greenberg, R. J., daCruz, L., & Argus II Study Group (2013) · Translational Vision Science & Technology · doi:10.1167/tvst.2.4.1 · Cited by 123 · see citing works
Self-citationChenais, N. A. L., Airaghi Leccardi, M. J. I., & Ghezzi, D. (2021) · Communications Materials · doi:10.1038/s43246-021-00133-2 · Cited by 110 · see citing works
Electronic approaches to restoration of sight
Goetz, G. A., & Palanker, D. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/9/096701 · Cited by 99 · see citing works
Jepson, L. H., Hottowy, P., Mathieson, K., Gunning, D. E., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.4967-12.2013 · Cited by 97 · see citing works
Electrical Stimulation of the Retina to Produce Artificial Vision
Weiland, J. D., Walston, S. T., & Humayun, M. S. (2016) · Annual Review of Vision Science · doi:10.1146/annurev-vision-111815-114425 · Cited by 85 · see citing works
Self-citationThe Argus™ II retinal prosthesis: Factors affecting patient selection for implantation
Ahuja, A., & Behrend, M. R. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.01.002 · Cited by 82 · see citing works
Self-citationStrength–duration relationship for intra- versus extracellular stimulation with microelectrodes
Rattay, F., Paredes, L. P., & Leão, R. N. (2012) · Neuroscience · doi:10.1016/j.neuroscience.2012.04.004 · Cited by 81 · see citing works
Spatially selective activation of the visual cortex via intraneural stimulation of the optic nerve
Gaillet, V., Cutrone, A., Artoni, F., Vagni, P., Mega Pratiwi, A., Romero, S. A., Lipucci Di Paola, D., Micera, S., & Ghezzi, D. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0446-8 · Cited by 73 · see citing works
Stimulation strategies for improving the resolution of retinal prostheses
Tong, W., Meffin, H., Garrett, D. J., & Ibbotson, M. R. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00262 · Cited by 66 · see citing works
Attaining higher resolution visual prosthetics: a review of the factors and limitations
Eiber, C. D., Lovell, N. H., & Suaning, G. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/1/011002 · Cited by 71 · see citing works
Microsaccade Characteristics in Neurological and Ophthalmic Disease
Alexander, R. G., Macknik, S. L., & Martínez‐Conde, S. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00144 · Cited by 67 · see citing works
Characteristics of prosthetic vision in rats with subretinal flat and pillar electrode arrays
Ho, E., Lei, X., Flores, T., Lorach, H., Huang, T., Galambos, L., Kamins, T., Harris, J., Mathieson, K., & Palanker, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab34b3 · Cited by 65 · see citing works
Electric stimulus duration alters network-mediated responses depending on retinal ganglion cell type
Im, M., Werginz, P., & Fried, S. I. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaadc1 · Cited by 58 · see citing works
Neural stimulation for visual rehabilitation: Advances and challenges
Lorach, H., Marre, O., Sahel, J., Benosman, R. B., & Picaud, S. A. (2012) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2012.10.003 · Cited by 51 · see citing works
Weitz, A. C., Behrend, M. R., Lee, N. S., Klein, R. L., Chiodo, V. A., Hauswirth, W. W., Humayun, M. S., Weiland, J. D., & Chow, R. H.-P. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00852.2012 · Cited by 51 · see citing works
Self-citationResponses to pulsatile subretinal electric stimulation: effects of amplitude and duration
Lee, S. W., Eddington, D. K., & Fried, S. I. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00293.2012 · Cited by 47 · see citing works
Subretinal Photovoltaic Implant to Restore Vision in Geographic Atrophy Due to AMD
Holz, F. G., Mer, Y. L., Muqit, M. M. K., Kuhli-Hattenbach, C., Cusumano, A., Grisanti, S., Kodjikian, L., Pileri, M., Matonti, F., Souied, E. H., et al. (2025) · New England Journal of Medicine · doi:10.1056/nejmoa2501396 · Cited by 53 · see citing works
Deep Learning–Based Scene Simplification for Bionic Vision
Han, N., Srivastava, S., Xu, A., Klein, D., & Beyeler, M. (2021) · Augmented Humans Conference 2021 · doi:10.1145/3458709.3458982 · Cited by 45 · see citing works
Advances in visual prostheses: engineering and biological challenges
Borda, E., & Ghezzi, D. (2022) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac812c · Cited by 44 · see citing works
Lee, J.-I., & Im, M. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2939012 · Cited by 39 · see citing works
Loizos, K., Marc, R. E., Humayun, M. S., Anderson, J. R., Jones, B. W., & Lazzi, G. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2832055 · Cited by 37 · see citing works
Self-citationSolenoidal Micromagnetic Stimulation Enables Activation of Axons With Specific Orientation
Golestanirad, L., Gale, J. T., Manzoor, N. F., Park, H.-J., Glait, L., Haer, F., Kaltenbach, J. A., & Bonmassar, G. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00724 · Cited by 37 · see citing works
Micro-Coil Design Influences the Spatial Extent of Responses to Intracortical Magnetic Stimulation
Lee, S. W., Thyagarajan, K., & Fried, S. I. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2877713 · Cited by 37 · see citing works
Prosthetic vision: devices, patient outcomes and retinal research
Hadjinicolaou, A. E., Hamish Meffin, A., Maturana, M. I., Cloherty, S. L., & Ibbotson, M. R. (2015) · Clinical and Experimental Optometry · doi:10.1111/cxo.12342 · Cited by 35 · see citing works
Lu, Y., Yan, Y., Chai, X., Ren, Q., Chen, Y., & Li, L. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036022 · Cited by 32 · see citing works
Layer-specific parameters of intracortical microstimulation of the somatosensory cortex
Urdaneta, M. E., Kunigk, N. G., Delgado, F., Fried, S. I., & Otto, K. J. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abedde · Cited by 31 · see citing works
Eickenscheidt, M., & Zeck, G. M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036006 · Cited by 29 · see citing works
Chenais, N. A. L., Leccardi, M. J. I. A., & Ghezzi, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab3913 · Cited by 24 · see citing works
Direct measurement of bipolar cell responses to electrical stimulation in wholemount mouse retina
Walston, S. T., Chow, R. H.-P., & Weiland, J. D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab4ed · Cited by 28 · see citing works
Self-citationElectrochemical characteristics of microelectrode designed for electrical stimulation
Cui, H., Xie, X., Xu, S., Chan, L. L.-H., & Hu, Y. S. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0704-8 · Cited by 28 · see citing works
Palanker, D. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-809324-5.24123-0 · Cited by 27 · see citing works
Effects of Depth-Based Object Isolation in Simulated Retinal Prosthetic Vision
Avraham, D., & Yitzhak Yitzhaky, B. (2021) · Symmetry · doi:10.3390/sym13101763 · Cited by 26 · see citing works
Reduction of Edge Effect on Disk Electrodes by Optimized Current Waveform
Wang, B., Petrossians, A., & Weiland, J. D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300860 · Cited by 26 · see citing works
Self-citationTanamoto, R., Shindo, Y., Miki, N., Matsumoto, Y., Hotta, K., & Oka, K. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.07.002 · Cited by 25 · see citing works
Yang, C. Y., Tsai, D., Guo, T., Dokos, S., Suaning, G. J., Morley, J. W., & Lovell, N. H. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac315 · Cited by 25 · see citing works
Paknahad, J., Loizos, K., Humayun, M. S., & Lazzi, G. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3027560 · Cited by 24 · see citing works
Self-citationLyu, Q., Lu, Z., Li, H., Qiu, S., Guo, J., Sui, X., Sun, P., Li, L., Chai, X., & Lovell, N. H. (2019) · International Journal of Neural Systems · doi:10.1142/s0129065720500069 · Cited by 22 · see citing works
Loizos, K., RamRakhyani, A. K., Anderson, J., Marc, R. E., & Lazzi, G. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/12/4491 · Cited by 22 · see citing works
Immersive Virtual Reality Simulations of Bionic Vision
Kasowski, J., & Beyeler, M. (2022) · Augmented Humans 2022 · doi:10.1145/3519391.3522752 · Cited by 18 · see citing works
Spatially patterned bi-electrode epiretinal stimulation for axon avoidance at cellular resolution
Vilkhu, R. S., Madugula, S. S., Grosberg, L. E., Gogliettino, A. R., Hottowy, P., Dąbrowski, W., Sher, A., Litke, A. M., Mitra, S., & Chichilnisky, E. J. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3450 · Cited by 18 · see citing works
Kim, Y. H., Koo, H., Kim, M. S., & Jung, S.-D. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.06.045 · Cited by 18 · see citing works
Italiano, M. L., Guo, T., Lovell, N. H., & Tsai, D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac72c2 · Cited by 16 · see citing works
Song, X., Qiu, S., Shivdasani, M. N., Zhou, F., Liu, Z., Ma, S., Chai, X., Chen, Y., Cai, X., Guo, T., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5b18 · Cited by 16 · see citing works
Yuhong, Z., Liu, X., Ma, J., Wang, Z., Jiang, H., Sun, C., Jeong, D., Guan, H., & Chu, B. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c12460 · Cited by 15 · see citing works
Virtual electrode design for increasing spatial resolution in retinal prosthesis
Loizos, K., Cela, C., Marc, R. E., & Lazzi, G. (2016) · Healthcare Technology Letters · doi:10.1049/htl.2015.0043 · Cited by 13 · see citing works
High Resolution Photovoltaic Subretinal Prosthesis for Restoration of Sight
Lorach, H., & Palanker, D. (2016) · Springer eBooks · doi:10.1007/978-3-319-41876-6_9 · Cited by 13 · see citing works
Short-pulsed micro-magnetic stimulation of the vagus nerve
Jeong, H., Cho, A., Ay, İ., & Bonmassar, G. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.938101 · Cited by 12 · see citing works
A 4.49nW/Pixel Light-to-Stimulus Duration Converter-Based Retinal Prosthesis Chip
Choi, D.-H., Roh, H., Im, M., & Jee, D. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3128418 · Cited by 12 · see citing works
Electrical stimulation of different retinal components and the effect of asymmetric pulses
Raz-Prag, D., Beit-Yaakov, G., & Hanein, Y. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.07.028 · Cited by 11 · see citing works
In vivo feasibility of epiretinal stimulation using ultrananocrystalline diamond electrodes
Shivdasani, M. N., Evans, M., Burns, O., Yeoh, J., Allen, P. J., Nayagam, D. A. X., Villalobos, J., Abbott, C. J., Luu, C. D., Opie, N. L., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba560 · Cited by 10 · see citing works
Paknahad, J., Humayun, M. S., & Lazzi, G. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3149967 · Cited by 9 · see citing works
Self-citationFarzad, S., Kosta, P., Iseri, E., Walston, S. T., Bouteiller, J. C., Pfeiffer, R. L., Sigulinsky, C., Yang, J., García, J. C. G., Anderson, J. R., et al. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3276431 · Cited by 9 · see citing works
Restoration of Sight with Electronic Retinal Prostheses
Palanker, D., Weiland, J. D., Rosin, B., & Sahel, J. (2025) · Annual Review of Vision Science · doi:10.1146/annurev-vision-110323-025244 · Cited by 10 · see citing works
Self-citationMinimizing axon bundle activation of retinal ganglion cells with oriented rectangular electrodes
Tong, W., Hejazi, M., Garrett, D. J., Esler, T. B., Prawer, S., Hamish Meffin, A., & Ibbotson, M. R. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab909e · Cited by 8 · see citing works
Lee, S. W., & Fried, S. I. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0019 · Cited by 7 · see citing works
What limits spatial perception with retinal implants?
Hamish Meffin, A. (2013) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2013.6738318 · Cited by 7 · see citing works
Sui, X., Huang, Y., Feng, F., Huang, C., Chan, L. L. H., & Wang, G. (2015) · The International Journal of Artificial Organs · doi:10.5301/ijao.5000412 · Cited by 7 · see citing works
Design and Simulation of a Ring Transducer Array for Ultrasound Retinal Stimulation
Xu, C., Lu, G., Kang, H., Humayun, M. S., & Zhou, Q. (2022) · Micromachines · doi:10.3390/mi13091536 · Cited by 5 · see citing works
Self-citationDeep Learning--Based Scene Simplification for Bionic Vision
Han, N., Srivastava, S., Xu, A., Klein, D., & Beyeler, M. (2021) · arXiv · doi:10.48550/arxiv.2102.00297 · Cited by 4 · see citing works
Photovoltaic, wireless wide‐field epiretinal prosthesis to treat retinitis pigmentosa
Schulz, A., Knoll, T., Jaeger, T., Harzic, R. L., Stracke, F., Wien, S., Olsommer, Y., Meiser, I., Wagner, S., Rammensee, M., et al. (2024) · Acta Ophthalmologica · doi:10.1111/aos.16733 · Cited by 4 · see citing works
Photovoltaic restoration of sight with high visual acuity in rats with retinal degeneration
Palanker, D., Goetz, G. A., Lorach, H., Mandel, Y., Smith, R., Boinagrov, D., Lei, X., Kamins, T. I., Harris, J. S., Mathieson, K., et al. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2081068 · Cited by 4 · see citing works
Haq, W., Basavaraju, S., Speck, A., & Zrenner, E. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac8ad0 · Cited by 4 · see citing works
Nakanishi, Y., Sasagawa, K., Siwadamrongpong, R., Shodo, K., Terasawa, Y., Takehara, H., Haruta, M., Tashiro, H., & Ohta, J. (2023) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/acb77d · Cited by 4 · see citing works
Kigure, C., Naganuma, H., Sasaki, Y., Kino, H., Tomita, H., & Tanaka, T. (2013) · Japanese Journal of Applied Physics · doi:10.7567/jjap.52.04cl03 · Cited by 4 · see citing works
Analysis of the Peak Resistance Frequency Method
Wang, B., & Weiland, J. D. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2510335 · Cited by 4 · see citing works
Self-citationQiu, S., Li, X., Li, X., & Li, L. (2017) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2017.8008352 · Cited by 4 · see citing works
Weitz, A. C., & Weiland, J. D. (2014) · Springer eBooks · doi:10.1007/978-1-4614-8151-5_7 · Cited by 4 · see citing works
Self-citationJosimovich, J. B., Soffronoff, P., Starkovsky, N. A., & Mueller‐Heubach, E. (1977) · PubMed · Cited by 4 · see citing works
Development of a chemical retinal prosthesis: Stimulation of rat retina with glutamate
Rountree, C. M., Inayat, S., Troy, J. B., & Saggere, L. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610205 · Cited by 3 · see citing works
Homaei, M., Fathalilou, M., & Rezazadeh, G. (2025) · Acta Mechanica · doi:10.1007/s00707-025-04527-y · Cited by 2 · see citing works
Yoon, Y. H., Yue, L., & Humayun, M. S. (2020) · Springer eBooks · doi:10.1007/978-981-15-7644-7_34 · Cited by 2 · see citing works
Self-citationBiswas, S., Das, S., & Mahadevappa, M. (2017) · IET Science Measurement & Technology · doi:10.1049/iet-smt.2016.0315 · Cited by 2 · see citing works
(2017) · Strategic Study of CAE · doi:10.15302/j-sscae-2017.02.017 · Cited by 2 · see citing works
Self-healing Cell Tactile Sensor Fabricated Using Ultraflexible Printed Electrodes
Shimizu, M., Fujie, T., Umedachi, T., Shigaki, S., Kawashima, H., Saito, M., Ohashi, H., & Hosoda, K. (2020) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros45743.2020.9341005 · Cited by 2 · see citing works
1V 4.49nW/Pixel Retinal Prosthesis Chip with Light-to-Stimulus Duration Converter
Choi, D.-H., & Jee, D. (2021) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas51556.2021.9401380 · Cited by 2 · see citing works
Optimizing retinal prosthesis stimulation: Enhancing the avoidance of unintended axonal activation
Alqahtani, A. M. (2026) · Journal of King Saud University - Science · doi:10.25259/jksus_1361_2025 · Cited by 1 · see citing works
Geordi’s Visor: A Vision of the Future
Lasbury, M. E. (2016) · Springer eBooks · doi:10.1007/978-3-319-40914-6_7 · Cited by 1 · see citing works
CMOS Neural Probe With Multi-Turn Micro-coil Magnetic Stimulation
Szoka, E. C., Werth, J. C., Cleland, T. A., Fried, S. I., & Molnar, A. C. (2021) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas49922.2021.9644971 · Cited by 1 · see citing works
Calcium Imaging In Electrically Stimulated Flat-Mounted Retinas
Cunquero, M., Marsal, M., Castro‐Olvera, G., Walston, S. T., Duvan, F. T., Macias-Montero, J. G., Puigdengoles, C., Chmeissani, M., Garrido, J. A., & Loza‐Álvarez, P. (2023) · Journal of Visualized Experiments · doi:10.3791/65705 · Cited by 1 · see citing works
Simulation of electrode-tissue interface for electrical stimulation of retinal ganglion cells
Biswas, S., Das, S., & Mahadevappa, M. (2014) · IEEE International Conference on Electronics, Computing and Communication Technologies (CONECCT) · doi:10.1109/conecct.2014.6740341 · Cited by 1 · see citing works
Prosthetic Vision, Perceptual Effects
Dagnelie, G., & Stronks, H. C. (2014) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_657-1
Biomimetic stimulation of rat retinal ganglion cells with the neurotransmitter glutamate
Rountree, C. M., Inayat, S., Saggere, L., & Troy, J. B. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944153
Precise and Reliable Activation of Cortex with Micro-coils
Lee, S. W., & Fried, S. I. (2017) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-319-64373-1_3
Photovoltaic stimulation efficiently evokes network-mediated activity of retinal ganglion cellsPreprint
Chenais, N. A. L., Leccardi, M. J. I. A., & Ghezzi, D. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/652404
Prosthetic Vision, Perceptual Effects
Dagnelie, G., & Stronks, H. C. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_657
Prosthetic Vision, Perceptual Effects
Dagnelie, G., & Stronks, H. C. (2022) · Springer eBooks · doi:10.1007/978-1-0716-1006-0_657
Cunquero, M., Marsal, M., Castro-Olvera, G., Walston, S. T., Duvan, F. T., Macias-Montero, J. G., Puigdengoles, C., Chmeissani, M., Garrido, J. A., & Loza-Alvarez, P. (2023) · doi:10.3791/65705-v
Nakanishi, Y., Hattori, T., Sriitsaranusorn, W., Tso, K.-C., Shodo, K., Takehara, H., Sunaga, Y., Haruta, M., Tashiro, H., Terasawa, Y., et al. (2025) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ad99e0
Short Pulse Epiretinal Stimulation Allows Focal Activation of Retinal Ganglion Cells
Koppenwallner, L. X., Zeck, G. M., & Werginz, P. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3529940
- Authors
- Behrend, M. R., Ahuja, A. K., Humayun, M. S., Chow, R. H., & Weiland, J. D.
- Affiliations
- University of Southern California (US)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-08
- Volume
- 19
- Issue
- 4
- Pages
- 436-442
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- PMC
- PMC3356684
- OpenAlex
- W2142922154
- Cited by
- 102
- References
- 40
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 2 · 2023: 3 · 2022: 10 · 2021: 9 · 2020: 9 · 2019: 7 · 2018: 9 · 2017: 5 · 2016: 9 · 2015: 10 · 2014: 6 · 2013: 11 · 2012: 2
- FWCI
- 2.52
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Eye Institute (R29EY011888)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinal Development and Disorders
- Keywords
- epiretinal prosthesis, retinal prosthesis, electrode size, spatial resolution, retinal ganglion cells, calcium imaging, salamander retina, visual acuity, retinal stimulation
- MeSH terms
- Algorithms, Animals, Electric Stimulation, Electrodes, Gels, Prosthesis Design, Retina, Retinal Ganglion Cells, Sensory Thresholds, Caudata, Urodela, Vision, Ocular, Visual Acuity, Visual Prosthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review