Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Open accessAbstract
Objective . Foreign body response to indwelling cortical microelectrodes limits the reliability of neural stimulation and recording, particularly for extended chronic applications in behaving animals. The extent to which this response compromises the chronic stability of neural devices depends on many factors including the materials used in the electrode construction, the size, and geometry of the indwelling structure. Here, we report on the development of microelectrode arrays (MEAs) based on amorphous silicon carbide (a-SiC). Approach . This technology utilizes a-SiC for its chronic stability and employs semiconductor manufacturing processes to create MEAs with small shank dimensions. The a-SiC films were deposited by plasma enhanced chemical vapor deposition and patterned by thin-film photolithographic techniques. To improve stimulation and recording capabilities with small contact areas, we investigated low impedance coatings on the electrode sites. The assembled devices were characterized in phosphate buffered saline for their electrochemical properties. Main results . MEAs utilizing a-SiC as both the primary structural element and encapsulation were fabricated successfully. These a-SiC MEAs had 16 penetrating shanks. Each shank has a cross-sectional area less than 60 µ m 2 and electrode sites with a geometric surface area varying from 20 to 200 µ m 2 . Electrode coatings of TiN and SIROF reduced 1 kHz electrode impedance to less than 100 kΩ from ~2.8 MΩ for 100 µ m 2 Au electrode sites and increased the charge injection capacities to values greater than 3 mC cm −2 . Finally, we demonstrated functionality by recording neural activity from basal ganglia nucleus of Zebra Finches and motor cortex of rat. Significance . The a-SiC MEAs provide a significant advancement in the development of microelectrodes that over the years has relied on silicon platforms for device manufacture. These flexible a-SiC MEAs have the potential for decreased tissue damage and reduced foreign body response. The technique is promising and has potential for clinical translation and large scale manufacturing.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Electrocorticography and micro-electrocorticography have enabled high-resolution temporal and spatial recordings useful in vivo, including for brain-computer interfaces.
“In practice, however, electrocorticography (ECoG) and microelectrocorticography (µECoG) have facilitated high temporal-and spatial-resolution recordings for effective use in in vivo applications 56,64,65 , including brain-computer interfaces.”
From The Layer 7 Cortical Interface: A Scalable and Minimally Invasive Brain–Computer Interface Platform (2022) · cites this paper as [56]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
The tension of metallic films deposited by electrolysis
Stoney, G. G. (1909) · Proceedings of the Royal Society of London Series A Containing Papers of a Mathematical and Physical Character · doi:10.1098/rspa.1909.0021 · Cited by 4,906 · see citing works
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · see citing works
Self-citationResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · see citing works
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875 · see citing works
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · see citing works
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S. T., Spence, A. J., Isaacson, M. S., Craighead, H. G., Turner, J. N., & Shain, W. G. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 798 · see citing works
Detection of dopamine dynamics in the brain
Wightman, R. M., May, L. J., & Michael, A. C. (1988) · Analytical Chemistry · doi:10.1021/ac00164a001 · Cited by 786 · see citing works
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740 · see citing works
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721 · see citing works
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · see citing works
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · see citing works
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622 · see citing works
Destexhe, A., Contreras, D., & Steriade, M. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-11-04595.1999 · Cited by 573 · see citing works
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544 · see citing works
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480 · see citing works
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 477 · see citing works
Ultramicroelectrodes in Electrochemistry
Heınze, J. (1993) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199312681 · Cited by 475 · see citing works
Detection of Dopamine Dynamics in the Brain
Wightman, R. M., May, L. J., & Michael, A. C. (1988) · Analytical Chemistry · doi:10.1021/ac00164a718 · Cited by 472 · see citing works
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462 · see citing works
Suner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415 · see citing works
Support for a synaptic chain model of neuronal sequence generation
Long, M. A., Jin, D. Z., & Fee, M. S. (2010) · Nature · doi:10.1038/nature09514 · Cited by 396 · see citing works
Williams, J. C., Rennaker, R. L., & Kipke, D. R. (1999) · Brain Research Protocols · doi:10.1016/s1385-299x(99)00034-3 · Cited by 396 · see citing works
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382 · see citing works
Kipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 364 · see citing works
Single unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358 · see citing works
Fee, M. S., Mitra, P. P., & Kleinfeld, D. (1996) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)00050-7 · Cited by 357 · see citing works
Using noise signature to optimize spike-sorting and to assess neuronal classification quality
Pouzat, C., Mazor, O., & Laurent, G. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00276-5 · Cited by 310 · see citing works
Ultramicroelectrodes: Design, Fabrication, and Characterization
Zoski, C. G. (2002) · Electroanalysis · doi:10.1002/1521-4109(200208)14:15/16 · Cited by 309 · see citing works
Theory of ultramicroelectrodes
Aoki, K. (1993) · Electroanalysis · doi:10.1002/elan.1140050802 · Cited by 308 · see citing works
Ludwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/014001 · Cited by 283 · see citing works
A carbon-fiber electrode array for long-term neural recording
Guitchounts, G., Markowitz, J. E., Liberti, W. A., & Gardner, T. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046016 · Cited by 224 · see citing works
Self-citationBeebe, X., & Rose, T. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.2122 · Cited by 220 · see citing works
Chronic <i>in vivo</i> stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204 · see citing works
Auditory responses in the zebra finch's motor system for song
Katz, L. C., & Gurney, M. E. (1981) · Brain Research · doi:10.1016/0006-8993(81)91073-8 · Cited by 194 · see citing works
Sputtered iridium oxide films for neural stimulation electrodes
Cogan, S. F., Ehrlich, J., Plante, T. D., Smirnov, A., Shire, D. B., Gingerich, M. D., & Rizzo, J. F. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31223 · Cited by 188 · see citing works
Self-citationWinslow, B. D., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.049 · Cited by 178 · see citing works
Plasma‐enhanced chemical vapor deposited silicon carbide as an implantable dielectric coating
Cogan, S. F., Edell, D. J., Guzelian, A. A., Liu, Y. P., & Edell, R. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10152 · Cited by 170 · see citing works
Self-citationCogan, S. F., Troyk, P. R., Ehrlich, J., & Plante, T. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851503 · Cited by 162 · see citing works
Self-citationBarrese, J. C., Aceros, J., & Donoghue, J. P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026003 · Cited by 161 · see citing works
Patel, P. R., Na, K., Zhang, H., Kozai, T. D. Y., Kotov, N. A., Yoon, E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046009 · Cited by 160 · see citing works
3D Parylene sheath neural probe for chronic recordings
Kim, B. J., Kuo, J. T. W., Hara, S. A., Lee, C. D., Liu, Y., Gutierrez, C. A., Hoang, T., Pikov, V., & Meng, E. F. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045002 · Cited by 155 · see citing works
Demonstration of cortical recording using novel flexible polymer neural probes
Mercanzini, A., Cheung, K. C., Buhl, D. L., Boers, M., Maillard, A., Colin, P., Bensadoun, J., Bertsch, A., & Renaud, P. (2007) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2007.07.027 · Cited by 151 · see citing works
Model-based analysis of cortical recording with silicon microelectrodes
Moffitt, M. A., & McIntyre, C. C. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.05.018 · Cited by 150 · see citing works
SU-8 based microprobes for simultaneous neural depth recording and drug delivery in the brain
Altuna, A., Bellistri, E., Cid, E., Aivar, P., Gal, B., Berganzo, J., Gabriel, G., Guimerà‐Brunet, A., Villa, R., Fernández, L. J., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc41364k · Cited by 129 · see citing works
Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00009-1 · Cited by 111 · see citing works
Chen, Y., Lai, H.-Y., Lin, S.-H., Chao, W.-H., Chao, W.-H., Liao, C., Tsang, S., Chen, Y., & Lin, S.-Y. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.05.010 · Cited by 110 · see citing works
Hsu, J.-M., Tathireddy, P., Rieth, L. W., Normann, A. R., & Solzbacher, F. (2007) · Thin Solid Films · doi:10.1016/j.tsf.2007.04.050 · Cited by 104 · see citing works
Intracellular Characterization of Song-Specific Neurons in the Zebra Finch Auditory Forebrain
Lewicki, M. S. (1996) · Journal of Neuroscience · doi:10.1523/jneurosci.16-18-05854.1996 · Cited by 104 · see citing works
Two distinct activity patterns of fast-spiking interneurons during neocortical UP states
Puig, M. V., Ushimaru, M., & Kawaguchi, Y. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0712219105 · Cited by 98 · see citing works
Thin microelectrodes reduce GFAP expression in the implant site in rodent somatosensory cortex
Stice, P., Gilletti, A., Panitch, A., & Muthuswamy, J. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/005 · Cited by 97 · see citing works
Freire, M. A. M., Morya, E., Faber, J., dos Santos, J. R., Guimarães, J. S., Lemos, N. A. M., Sameshima, K., Pereira, A., Ribeiro, S. T. G., & Nicolelis, M. A. L. (2011) · PLoS ONE · doi:10.1371/journal.pone.0027554 · Cited by 97 · see citing works
Electrical Performance of Penetrating Microelectrodes Chronically Implanted in Cat Cortex
Kane, S. R., Cogan, S. F., Ehrlich, J., Plante, T. D., McCreery, D. B., & Troyk, P. R. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2248152 · Cited by 95 · see citing works
Self-citationCurrent Density Profiles of Surface Mounted and Recessed Electrodes for Neural Prostheses
Rubinstein, J. T., Spelman, F. A., Soma, M., & Suesserman, M. F. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326007 · Cited by 89 · see citing works
Cogan, S. F., Troyk, P. R., Ehrlich, J., Gasbarro, C. M., & Plante, T. D. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/008 · Cited by 88 · see citing works
Self-citationCochlear nucleus auditory prostheses
McCreery, D. B. (2008) · Hearing Research · doi:10.1016/j.heares.2007.11.014 · Cited by 88 · see citing works
Suesserman, M. F., Spelman, F. A., & Rubinstein, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.81558 · Cited by 83 · see citing works
Low-stress PECVD SiC thin films for IC-compatible microstructures
Sarro, P. M., deBoer, C. R., Korkmaz, E., et al. (1998) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)01730-5 · Cited by 73 · see citing works
PECVD amorphous silicon carbide membranes for cell culturing
Iliescu, C., Chen, B., Poenar, D. P., et al. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.08.043 · Cited by 67 · see citing works
An ultra-compliant, scalable neural probe with molded biodissolvable delivery vehicle
Gilgunn, P. J., Khilwani, R., Kozai, T. D. Y., Weber, D. J., Cui, X. T., Erdös, G., Özdoğanlar, O. B., & Fedder, G. K. (2012) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2012.6170092 · Cited by 65 · see citing works
SiC protective coating for photovoltaic retinal prosthesis
Lei, X., Kane, S. R., Cogan, S. F., Lorach, H., Galambos, L., Huie, P., Mathieson, K., Kamins, T. I., Harris, J. S., & Palanker, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046016 · Cited by 64 · see citing works
Self-citationClinical outcomes of silicon carbide coated stents in patients with coronary artery disease.
Kalnins, U., Ērglis, A., Dinne, I., et al. (2002) · PubMed · Cited by 57 · see citing works
In vivo Characterization of Amorphous Silicon Carbide As a Biomaterial for Chronic Neural Interfaces
Knaack, G. L., McHail, D. G., Borda, G., Koo, B., Peixoto, N., Cogan, S. F., Dumas, T. C., & Pancrazio, J. J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00301 · Cited by 51 · see citing works
Self-citationCyclic Voltammetry with Ultramicroelectrodes
Ching, S., Dudek, R. C., & Tabet, E. A. (1994) · Journal of Chemical Education · doi:10.1021/ed071p602 · Cited by 50 · see citing works
"Safe" charge-injection waveforms for iridium oxide (AIROF) microelectrodes
Troyk, P. R., Detlefsen, D. E., Cogan, S. F., Ehrlich, J., Bak, M., McCreery, D. B., Bullara, L. A., & Schmidt, E. J. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404155 · Cited by 44 · see citing works
Self-citationSilicon carbide coated MEMS strain sensor for harsh environment applications
Azevedo, R. G., Zhang, J., Jones, D. G., et al. (2007) · Proceedings, IEEE micro electro mechanical systems · doi:10.1109/memsys.2007.4433166 · Cited by 38 · see citing works
A Multimodal, SU-8 - Platinum - Polyimide Microelectrode Array for Chronic In Vivo Neurophysiology
Márton, G., Orbán, G., Kiss, M., Fiáth, R., Pongracz, A., & Ulbert, I. (2015) · PLoS ONE · doi:10.1371/journal.pone.0145307 · Cited by 36 · see citing works
Physical principles for scalable neural recording
Marblestone, A. H., Zamft, B. M., Maguire, Y. G., Shapiro, M. G., Cybulski, T. R., Glaser, J. I., Amodei, D., Stranges, P. B., Kalhor, R., Dalrymple, D., et al. (2013) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2013.00137 · Cited by 27 · see citing works
Chronic in-vivo testing of a 16-channel implantable wireless neural stimulator
Bredeson, S. D., Kanneganti, A., Deku, F., Cogan, S. F., Romero‐Ortega, M. I., & Troyk, P. R. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318537 · Cited by 27 · see citing works
Self-citationSilicon Carbide as a Material for Biomedical Microsystems
Zorman, C. A. (2009) · Cited by 24 · see citing works
In vitro and in vivo testing of a wireless multichannel stimulating telemetry microsystem
Ghovanloo, M., Otto, K. J., Kipke, D. R., et al. (2005) · doi:10.1109/iembs.2004.1404196 · Cited by 23 · see citing works
Eleryan, A., Vaidya, M., Southerland, J., Badreldin, I. S., Balasubramanian, K., Fagg, A. H., Hatsopoulos, N., & Oweiss, K. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00023 · Cited by 20 · see citing works
Embedded Ultrathin Cluster Electrodes for Long-Term Recordings in Deep Brain Centers
Etemadi, L., Mohammed, M., Thorbergsson, P. T., Ekstrand, J., Friberg, A., Granmo, M., Pettersson, L. M. E., & Schouenborg, J. (2016) · PLoS ONE · doi:10.1371/journal.pone.0155109 · Cited by 20 · see citing works
Residual stress in thin films PECVD depositions: A review
Iliescu, C., Avram, M., Chen, B., et al. (2011) · Cited by 17 · see citing works
The effect of electrode geometry on electrochemical properties measured in saline
Cogan, S. F., Ehrlich, J., & Plante, T. D. (2014) · doi:10.1109/embc.2014.6945202 · Cited by 15 · see citing works
Self-citationLow stress PECVD amorphous silicon carbide for MEMS applications
Avram, M., Avram, A. M., Brăgaru, A., et al. (2010) · doi:10.1109/smicnd.2010.5650647 · Cited by 12 · see citing works
Chronic and low charge injection wireless intraneural stimulation in vivo
Romero‐Ortega, M. I., Kanneganti, A., Bendale, G. S., et al. (2015) · doi:10.1109/embc.2015.7318536 · Cited by 8 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
An Integrated Brain-Machine Interface Platform With Thousands of Channels
Musk, E., & Neuralink (2019) · Journal of Medical Internet Research · doi:10.2196/16194 · Cited by 1,206 · see citing works
Recent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206 · see citing works
The future of neuroscience: flexible and wireless implantable neural electronics
McGlynn, E., Nabaei, V., Ren, E., Galeote‐Checa, G., Das, R., Curia, G., & Heidari, H. (2021) · Advanced Science · doi:10.1002/advs.202002693 · Cited by 115 · see citing works
The Layer 7 Cortical Interface: A Scalable and Minimally Invasive Brain–Computer Interface Platform
Hettick, M., Ho, E., Poole, A. J., Monge, M., Papageorgiou, D., Takahashi, K., LaMarca, M., Trietsch, D., Reed, K., Murphy, M., et al. (2022) · doi:10.1101/2022.01.02.474656 · Cited by 31 · see citing works
NeuroBus - Architecture for an Ultra-Flexible Neural Interface
Sporer, M., Vasilaş, I.-G., Adžemović, A., Graber, N., Reich, S., Gueli, C., Eickenscheidt, M., Diester, I., Stieglitz, T., & Ortmanns, M. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3354785 · Cited by 13 · see citing works
- Authors
- Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F.
- Affiliations
- The University of Texas at Dallas (US)
- Boston University (US)
- University of Texas at Dallas
- Corresponding author
- Cogan, Stuart F
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2018-01-08
- Volume
- 15
- Issue
- 1
- Pages
- 016007
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC5786446
- OpenAlex
- W2758700888
- Cited by
- 89
- References
- 77
- Citations by year
- 2026: 2 · 2025: 13 · 2024: 9 · 2023: 12 · 2022: 14 · 2021: 14 · 2020: 7 · 2019: 8 · 2018: 10
- FWCI
- 3.34
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- NIH (U01NS090454)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- amorphous silicon carbide, microelectrode arrays, neurostimulation, neural recording, foreign body reaction, electrode impedance, TiN coating, charge injection capacity, zebra finch, plasma-enhanced chemical vapor deposition
- MeSH terms
- Animals, Basal Ganglia, Electric Stimulation, Electrodes, Implanted, Microelectrodes, Motor Cortex, Carbon Compounds, Inorganic, Silicon Compounds, Coated Materials, Biocompatible, Finches, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review