The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
A brain-controlled switch for asynchronous control applications
Abstract
Asynchronous control applications are an important class of application that has not received much attention from the brain-computer interface (BCI) community. This work provides a design for an asynchronous BCI switch and performs the first extensive evaluation of an asynchronous device in attentive, spontaneous electroencephalographic (EEG). The switch design [named the low-frequency asynchronous switch design (LF-ASD)] is based on a new feature set related to imaginary movements in the 1-4 Hz frequency range. This new feature set was identified from a unique analysis of EEG using a bi-scale wavelet. Offline evaluations of a prototype switch demonstrated hit (true positive) rates in the range of 38%-81% with corresponding false positive rates in the range of 0.3%-11.6%. The performance of the LF-ASD was contrasted with two other ASDs: one based on mu-power features and another based on the outlier processing method (OPM) algorithm. The minimum mean error rates for the LF-ASD were shown to be significantly lower than either of these other two switch designs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1966) · Medical Entomology and Zoology · Cited by 10,293
Signal detection theory and psychophysics
Ingleby, J. D. (1967) · Journal of Sound and Vibration · doi:10.1016/0022-460x(67)90197-6 · Cited by 8,509
Kohonen, T. (1990) · Proceedings of the IEEE · doi:10.1109/5.58325 · Cited by 8,414
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Supplementary motor area structure and function: Review and hypotheses
Goldberg, G. (1985) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00045167 · Cited by 1,233
An EEG-based brain-computer interface for cursor control
Wolpaw, J. R., McFarland, D. J., Neat, G. W., & Forneris, C. A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90040-b · Cited by 1,114
EEG-based discrimination between imagination of right and left hand movement
Pfurtscheller, G., Neuper, C., Flotzinger, D., & Pregenzer, M. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00080-1 · Cited by 904
Deecke, L., Scheid, P., & Kornhuber, H. (1969) · Experimental Brain Research · doi:10.1007/bf00235441 · Cited by 748
Brain-Computer Interface—a new communication device for handicapped persons
Pfurtscheller, G., Flotzinger, D., & Kalcher, J. (1993) · Journal of Microcomputer Applications · doi:10.1006/jmca.1993.1030 · Cited by 502
Topography of the human motor potential
Vaughan, H. G., Costa, L. D., & Ritter, W. (1968) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(68)90080-1 · Cited by 452
Cited by
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Self-citationEMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
Self-citationPfurtscheller, G. (2010) · Frontiers in Neuroscience · doi:10.3389/fnpro.2010.00003 · Cited by 625
An accumulator model for spontaneous neural activity prior to self-initiated movement
Schurger, A., Sitt, J. D., & Dehaene, S. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210467109 · Cited by 505
Brain–computer interface using a simplified functional near-infrared spectroscopy system
Coyle, S. M., Ward, T. E., & Markham, C. M. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/007 · Cited by 505
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
A Hybrid BCI System Combining P300 and SSVEP and Its Application to Wheelchair Control
Li, Y., Pan, J., Wang, F., & Yu, Z. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2270283 · Cited by 421
Linear and nonlinear methods for brain-computer interfaces
Muller, K.-R., Anderson, C. W., & Birch, G. E. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814484 · Cited by 360
Self-citationAn Asynchronously Controlled EEG-Based Virtual Keyboard: Improvement of the Spelling Rate
Scherer, R., Muller, G. R., Neuper, C., Graimann, B., & Pfurtscheller, G. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827062 · Cited by 340
A general framework for brain-computer interface design
Mason, S. G., & Birch, G. E. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.810426 · Cited by 331
Self-citationA Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Self-citationBrain–Computer Interfaces: A Gentle Introduction
Graimann, B., Allison, B., & Pfurtscheller, G. (2009) · The Frontiers Collection · doi:10.1007/978-3-642-02091-9_1 · Cited by 298
Continuous EEG classification during motor imagery-simulation of an asynchronous BCI
Townsend, G., Graimann, B., & Pfurtscheller, G. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827220 · Cited by 276
Detection of movement intention from single-trial movement-related cortical potentials
Niazi, I. K., Jiang, N., Tiberghien, O., Nielsen, J. F., Dremstrup, K., & Farina, D. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066009 · Cited by 259
Noninvasive Brain-Computer Interfaces Based on Sensorimotor Rhythms
He, B., Baxter, B., Edelman, B. J., Cline, C. C., & Ye, W. W. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2407272 · Cited by 233
Birch, G. E., Bozorgzadeh, Z., & Mason, S. G. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806839 · Cited by 97
Self-citationBoye, A. T., Kristiansen, U. Q., Billinger, M., Nascimento, O. F. D., & Farina, D. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2008.05.001 · Cited by 45
Benchmarking Brain-Computer Interfaces Outside the Laboratory: The Cybathlon 2016
Novak, D., Sigrist, R., Gerig, N. J., Wyss, D., Bauer, R., Götz, U., & Riener, R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00756 · Cited by 41
Quantitative EEG for Brain–Computer Interfaces
(2014) · EEG/ERP Analysis · doi:10.1201/b17605-11 · Cited by 9
Metadata
- Authors
- Mason, S. G., & Birch, G. E.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000
- Volume
- 47
- Issue
- 10
- Pages
- 1297-1307
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2098590735
- Cited by
- 293
- References
- 19
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.