The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Metal streak artifacts in X-ray computed tomography: a simulation study
Abstract
Metal streak artifacts are an important problem in X-ray computed tomography. A high-resolution 2D fan-beam computed tomography simulator is presented. Several potential causes of metal streak artifacts are studied using phantom measurements and simulations. Beam hardening, scatter, noise and exponential edge-gradient effects are identified as important causes of metal streak artifacts. Furthermore, aliasing effects and object motion can be also responsible for certain metal streak artifacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image Reconstruction from Projections
(2004) · Biomedical Engineering · doi:10.1201/9780203492543.ch9 · Cited by 915
Reduction of CT artifacts caused by metallic implants.
Kalender, W. A., Hebel, R., & Ebersberger, J. (1987) · Radiology · doi:10.1148/radiology.164.2.3602406 · Cited by 751
Iterative deblurring for CT metal artifact reduction
Wang, G., Snyder, D. L., O'Sullivan, J. A., & Vannier, M. W. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538943 · Cited by 409
Iterative reconstruction for helical CT: a simulation study
Nuyts, J., Man, B. D., Dupont, P., Defrise, M., Suetens, P., & Mortelmans, L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/003 · Cited by 291
Self-citationA Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners
Joseph, P. M., & Spital, R. D. (1978) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197801000-00017 · Cited by 281
The effects of scatter in x‐ray computed tomography
Joseph, P. M., & Spital, R. D. (1982) · Medical Physics · doi:10.1118/1.595111 · Cited by 211
Compton scatter effects in CT reconstructions
Glover, G. H. (1982) · Medical Physics · doi:10.1118/1.595197 · Cited by 167
Total Hip Prosthesis Metal-Artifact Suppression Using Iterative Deblurring Reconstruction
Robertson, D. D., Yuan, J., Wang, G., & Vannier, M. W. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199703000-00024 · Cited by 115
The exponential edge-gradient effect in X-ray computed tomography
Joseph, P. M., & Spital, R. D. (1981) · Physics in Medicine and Biology · doi:10.1088/0031-9155/26/3/010 · Cited by 113
Joseph, P. M., & Ruth, C. (1997) · Medical Physics · doi:10.1118/1.597970 · Cited by 111
Cited by
Cnudde, V., & Boone, M. N. (2013) · Earth-Science Reviews · doi:10.1016/j.earscirev.2013.04.003 · Cited by 1,572
Schulze, R., Heil, U., Groβ, D., Bruellmann, D., Dranischnikow, E., Schwanecke, U., & Schoemer, E. (2011) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/30642039 · Cited by 999
CT artifacts: causes and reduction techniques
Boas, F. E., & Fleischmann, D. (2012) · Imaging in Medicine · doi:10.2217/iim.12.13 · Cited by 848
Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography
Zhang, Y., & Yu, H. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823083 · Cited by 493
Distance-driven projection and backprojection in three dimensions
Man, B. D., & Basu, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/11/024 · Cited by 459
Metadata
- Authors
- De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 1999-06
- Volume
- 46
- Issue
- 3
- Pages
- 691-696
- ISSN
- 0018-9499 (ISSN-L)
- 1558-1578
- OpenAlex
- W2111496814
- Cited by
- 311
- References
- 12
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metal streak artifacts in X-ray computed tomography: a simulation study. https://app.cochat.ai/papers/10.1109/23.775600
- The paper
- De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (1999). Metal streak artifacts in X-ray computed tomography: a simulation study. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/23.775600
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.