The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
An overview of research using the one atmosphere uniform glow discharge plasma (OAUGDP) for sterilization of surfaces and materials
Abstract
The medical, food processing, and heating, ventilating, and air conditioning industries are searching for improved pasteurization, disinfection, and sterilization technologies. Candidate techniques must deal with and overcome such problems as thermal sensitivity and destruction by heat, formation of toxic by-products, costs, and inefficiency in performance. We report the results of a plasma source, the One Atmosphere Uniform Glow Discharge Plasma (OAUGDP), which operates at atmospheric pressure in air and produces antimicrobial active species at room temperature, OAUGDP exposures have reduced log numbers of Gram negative and Gram positive bacteria, bacterial endospores, yeast, and bacterial viruses on a variety of surfaces. The nature of the surface influenced the degree of lethality, with microorganisms on polypropylene being most sensitive, followed by glass, and cells embedded in agar. Experimental results showed at least a 5 log/sub 10/ CFU reduction in bacteria within a range of 50-90 s of exposure. After 10-25 s of exposure, macromolecular leakage and bacterial fragmentation were observed. Vulnerability of cell membranes to reactive oxygen species (ROC) is hypothesized. Results from several novel OAUGDP configurations are presented, including a remote exposure reactor (RER) which uses transported active species to sterilize material located more than 20 cm from the plasma generation site, and a second planar electrode configuration developed for air filter sterilization. Applications of these technologies to the healthcare industry, the food industry, and decontaminating surfaces compromised by biological warfare agents are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Superoxide radical and superoxide dismutases
Fridovich, I. (1995) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.64.070195.000525 · Cited by 3,455
The atmospheric-pressure plasma jet: a review and comparison to other plasma sources
Schutze, A., Jeong, J. Y., Babayan, S. E., Park, J., Selwyn, G. S., & Hicks, R. F. (1998) · IEEE Transactions on Plasma Science · doi:10.1109/27.747887 · Cited by 1,401
Massines, F., Rabehi, A., Decomps, P., Gadri, R. B., Ségur, P., & Mayoux, C. (1998) · Journal of Applied Physics · doi:10.1063/1.367051 · Cited by 955
Stable glow plasma at atmospheric pressure
Kanazawa, S., Kogoma, M., Moriwaki, T., & Okazaki, S. (1988) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/21/5/028 · Cited by 697
Industrial Plasma Engineering: Volume 1: Principles
Reece Roth, J. (1995) · Taylor & Francis eBooks · doi:10.1201/9781420050868 · Cited by 575
Sterilization of contaminated matter with an atmospheric pressure plasma
Laroussi, M. (1996) · IEEE Transactions on Plasma Science · doi:10.1109/27.533129 · Cited by 517
The effect of pulsed electric fields on biological cells: experiments and applications
Schoenbach, K. H., Peterkin, F. E., Alden, R. W., & Beebe, S. J. (1997) · IEEE Transactions on Plasma Science · doi:10.1109/27.602501 · Cited by 317
Rutala, W. A., Gergen, M. F., & Weber, D. J. (1998) · American Journal of Infection Control · doi:10.1016/s0196-6553(98)70034-3 · Cited by 171
Plasma Deposition and Treatment for Biomaterial Applications
Ratner, B. D., Chilkoti, A., & López, G. P. (1990) · Elsevier eBooks · doi:10.1016/b978-0-12-200430-8.50013-0 · Cited by 133
Cited by
Dielectric-Barrier Discharges: Their History, Discharge Physics, and Industrial Applications
Kogelschatz, U. (2003) · Plasma Chemistry and Plasma Processing · doi:10.1023/a:1022470901385 · Cited by 3,193
Fridman, G., Friedman, G., Gutsol, A., Shekhter, A. B., Vasilets, V. N., & Fridman, A. (2008) · Plasma Processes and Polymers · doi:10.1002/ppap.200700154 · Cited by 2,084
Low Temperature Plasma‐Based Sterilization: Overview and State‐of‐the‐Art
Laroussi, M. (2005) · Plasma Processes and Polymers · doi:10.1002/ppap.200400078 · Cited by 1,111
Laroussi, M., & Leipold, F. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2003.11.016 · Cited by 866
Laroussi, M. (2002) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2002.804220 · Cited by 760
Gram positive and Gram negative bacteria differ in their sensitivity to cold plasma
Mai-Prochnow, A., Clauson, M., Hong, J., & Murphy, A. B. (2016) · Scientific Reports · doi:10.1038/srep38610 · Cited by 736
The Role of Acidification for Antimicrobial Activity of Atmospheric Pressure Plasma in Liquids
Oehmigen, K., Hähnel, M., Brandenburg, R., Wilke, C., Weltmann, K. ‐., & von Woedtke, T. (2010) · Plasma Processes and Polymers · doi:10.1002/ppap.200900077 · Cited by 726
Cold Plasma: A novel Non-Thermal Technology for Food Processing
Thirumdas, R., Sarangapani, C., & Annapure, U. S. (2015) · Food Biophysics · doi:10.1007/s11483-014-9382-z · Cited by 621
Low-Temperature Plasmas for Medicine?
Laroussi, M. (2009) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2009.2017267 · Cited by 619
Nonthermal Plasma Inactivation of Food-Borne Pathogens
Misra, N. N., Tiwari, B. K., Raghavarao, K. S. M. S., & Cullen, P. J. (2011) · Food Engineering Reviews · doi:10.1007/s12393-011-9041-9 · Cited by 599
Non-thermal plasma treatment of textiles
Morent, R., De Geyter, N., Verschuren, J., De Clerck, K., Kiekens, P., & Leys, C. (2008) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2007.12.027 · Cited by 596
Inactivation mechanisms of non-thermal plasma on microbes: A review
Liao, X., Liu, D., Xiang, Q., Ahn, J., Chen, S., Ye, X., & Ding, T. (2017) · Food Control · doi:10.1016/j.foodcont.2016.12.021 · Cited by 512
Ziuzina, D., Patil, S., Cullen, P. J., Keener, K. M., & Bourke, P. (2014) · Food Microbiology · doi:10.1016/j.fm.2014.02.007 · Cited by 441
Cold plasma interactions with enzymes in foods and model systems
Misra, N. N., Pankaj, S. K., Segat, A., & Ishikawa, K. (2016) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2016.07.001 · Cited by 422
Plasma interaction with microbes
Laroussi, M., Mendis, D. A., & Rosenberg, M. (2003) · New Journal of Physics · doi:10.1088/1367-2630/5/1/341 · Cited by 408
Emerging Technologies in Food Processing
Knorr, D., Froehling, A., Jaeger, H., Reineke, K., Schlueter, O., & Schoessler, K. (2011) · Annual Review of Food Science and Technology · doi:10.1146/annurev.food.102308.124129 · Cited by 408
Atmospheric pressure dielectric barrier discharges interacting with liquid covered tissue
Tian, W., & Kushner, M. J. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/16/165201 · Cited by 367
Gaunt, L. F., Beggs, C. B., & Georghiou, G. E. (2006) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2006.878381 · Cited by 342
Ramazzina, I., Berardinelli, A., Rizzi, F., Tappi, S., Ragni, L., Sacchetti, G., & Rocculi, P. (2015) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2015.04.008 · Cited by 313
Surface modification of polymer surfaces: atmospheric plasma versus vacuum plasma treatments
Shenton, M. J., & Stevens, G. C. (2001) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/34/18/308 · Cited by 308
Jayasena, D. D., Kim, H. J., Yong, H. I., Park, S., Kim, K., Choe, W., & Jo, C. (2015) · Food Microbiology · doi:10.1016/j.fm.2014.07.009 · Cited by 302
Gas Plasma: Medical Uses and Developments in Wound Care
Lloyd, G., Friedman, G., Jafri, S., Schultz, G., Fridman, A., & Harding, K. (2010) · Plasma Processes and Polymers · doi:10.1002/ppap.200900097 · Cited by 301
Microplasmas, an emerging field of low-temperature plasma science and technology
Foest, R., Schmidt, M., & Becker, K. (2006) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2005.11.010 · Cited by 286
Design Considerations for Hydrogel Wound Dressings: Strategic and Molecular Advances
Op 't Veld, R. C., Walboomers, X. F., Jansen, J. A., & Wagener, F. A. D. T. G. (2020) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2019.0281 · Cited by 276
Atmospheric pressure plasmas: Infection control and bacterial responses
Mai-Prochnow, A., Murphy, A. B., McLean, K. M., Kong, M. G., & Ostrikov, K. (. (2014) · International Journal of Antimicrobial Agents · doi:10.1016/j.ijantimicag.2014.01.025 · Cited by 275
Atmospheric gas plasma treatment of fresh-cut apples
Tappi, S., Berardinelli, A., Ragni, L., Dalla Rosa, M., Guarnieri, A., & Rocculi, P. (2014) · Innovative Food Science & Emerging Technologies · doi:10.1016/j.ifset.2013.09.012 · Cited by 255
A Review on Microbiological Decontamination of Fresh Produce with Nonthermal Plasma
Pignata, C., D'Angelo, D., Fea, E., & Gilli, G. (2017) · Journal of Applied Microbiology · doi:10.1111/jam.13412 · Cited by 121
Aparajhitha, S., & Mahendran, R. (2019) · Innovative Food Science & Emerging Technologies · doi:10.1016/j.ifset.2019.102230 · Cited by 42
Metadata
- Authors
- Montie, T. C., Kelly-Wintenberg, K., & Roth, J. R.
- Venue
- IEEE Transactions on Plasma Science
- Published
- 2000
- Volume
- 28
- Issue
- 1
- Pages
- 41-50
- ISSN
- 0093-3813 (ISSN-L)
- OpenAlex
- W2163124291
- Cited by
- 537
- References
- 9
- FWCI
- 8.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.