CoChat

A 64-site multishank CMOS low-profile neural stimulating probe

Changhyun Kim, Wise, K.D. · 1996 · IEEE Journal of Solid-State Circuits
Cited by 103

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Describes a low-profile micromachined CMOS probe for multisite stimulation and recording in the central nervous system. The probe uses flexible silicon interconnects to allow the signal processing portion of the probe to fold at right angles to the penetrating probe shanks, limiting the implanted profile above the cortex to less than 1 mm. The probe is designed to stimulate a 4 mm/sup 3/ volume of neural tissue with a spatial resolution of 400 /spl mu/m using 1000 /spl mu/m/sup 2/ electrode sites. Eight of the 64 sites on the probe can be driven simultaneously over a current range from -127 /spl mu/A to +127 /spl mu/A with 1 /spl mu/A resolution. An on-chip preamplifier allows the neural activity on any selected site to be recorded with an overall gain of 30 and bandwidth from 50 Hz to 9 kHz. The probe operates with a stimulus current linearity of 0.98 up to clock frequencies as high as 5 MHz and dissipates less than 15 /spl mu/A in standby from /spl plusmn/5 V supplies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/4.535406

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 11

  1. 10.1109/TBME.1974.324339 · DOI · Paper page
  2. 10.1109/10.2122 · DOI · Paper page
  3. 10.1109/4.121568 · DOI · Paper page
  4. 10.1109/JSSC.1985.1052457 · DOI
  5. 10.1109/10.43605 · DOI · Paper page
  6. 10.1109/TBME.1982.325031 · doi:10.1109/tbme.1982.325031
  7. 10.1109/10.335862 · DOI · Paper page
  8. kim, 1993, multichannel neural probes with on-chip cmos circuitry and high-current stimulating sites, Dig Int Conf Solid-State Sensors and Actuators, 454
  9. 10.1109/4.173111 · DOI
  10. agnew, 1990, Neural Prostheses Fundamental Studies
  11. lund, 1994, chip-level encapsulation of implantable cmos microelectrode arrays, Dig Solid-State Sensor and Actuator Workshop, 29

Cited by

See all 103

Metadata

Authors
Kim, C., & Wise, K. D.
Venue
IEEE Journal of Solid-State Circuits
Published
1996
Volume
31
Issue
9
Pages
1230-1238
ISSN
0018-9200 (ISSN-L)
OpenAlex
W2067918090
Cited by
103
References
2
FWCI
0.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.