The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Exact and approximate rebinning algorithms for 3-D PET data
Abstract
This paper presents two new rebinning algorithms for the reconstruction of three-dimensional (3-D) positron emission tomography (PET) data. A rebinning algorithm is one that first sorts the 3-D data into an ordinary two-dimensional (2-D) data set containing one sinogram for each transaxial slice to be reconstructed; the 3-D image is then recovered by applying to each slice a 2-D reconstruction method such as filtered-backprojection. This approach allows a significant speedup of 3-D reconstruction, which is particularly useful for applications involving dynamic acquisitions or whole-body imaging. The first new algorithm is obtained by discretizing an exact analytical inversion formula. The second algorithm, called the Fourier rebinning algorithm (FORE), is approximate but allows an efficient implementation based on taking 2-D Fourier transforms of the data. This second algorithm was implemented and applied to data acquired with the new generation of PET systems and also to simulated data for a scanner with an 18 degrees axial aperture. The reconstructed images were compared to those obtained with the 3-D reprojection algorithm (3DRP) which is the standard "exact" 3-D filtered-backprojection method. Results demonstrate that FORE provides a reliable alternative to 3DRP, while at the same time achieving an order of magnitude reduction in processing time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1972) · Cited by 17,806
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
The Mathematics of Computerized Tomography
Natterer, F., & Wang, G. (2002) · Medical Physics · doi:10.1118/1.1429631 · Cited by 2,524
The Mathematics of Computerized Tomography
Natterer, F. (1986) · Vieweg+Teubner eBooks · doi:10.1007/978-3-663-01409-6 · Cited by 1,768
Analytic 3D image reconstruction using all detected events
Kinahan, P. E., & Rogers, J. G. (1989) · IEEE Transactions on Nuclear Science · doi:10.1109/23.34585 · Cited by 767
Self-citationThe ECAT EXACT HR: Performance of a New High Resolution Positron Scanner
Wienhard, K., Dahlbom, M., Eriksson, L., Michel, C., Bruckbauer, T., Pietrzyk, U., & Heiss, W.-D. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199401000-00023 · Cited by 561
Self-citationModel-based scatter correction for fully 3D PET
Ollinger, J. M. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/012 · Cited by 393
Treatment of axial data in three-dimensional PET.
Daube-Witherspoon, M. E., & Muehllehner, G. (1987) · PubMed · Cited by 357
A Single Scatter Simulation Technique for Scatter Correction in 3D PET
Watson, C. C., Newport, D., & Casey, M. E. (1996) · Computational Imaging and Vision · doi:10.1007/978-94-015-8749-5_18 · Cited by 333
Self-citationPhysical performance of a positron tomograph for brain imaging with retractable septa
Spinks, T. J., Jones, T., Bailey, D. L., Townsend, D. W., Grootoonk, S., Bloomfield, P. M., Gilardi, M. C., Casey, M. E., Sipe, B., & Reed, J. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/8/002 · Cited by 293
Self-citationCompensation of tissue absorption in emission tomography
Bellini, S., Piacentini, M., Cafforio, C., & Rocca, F. (1979) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1979.1163232 · Cited by 231
3D PET using a Conventional Multislice Tomograph without Septa
Cherry, S. R., Dahlbom, M., & Hoffman, E. J. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199107000-00023 · Cited by 182
Glick, S. J., Penney, B. C., King, M. A., & Byrne, C. L. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293929 · Cited by 127
Fourier correction for spatially variant collimator blurring in SPECT
Xia, W., Lewitt, R. M., & Edholm, P. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.370406 · Cited by 116
Three-dimensional image reconstruction for PET by multi-slice rebinning and axial image filtering
Lewitt, R. M., Muehllehner, G., & Karp, J. S. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/3/002 · Cited by 107
Constrained Fourier space method for compensation of missing data in emission computed tomography
Karp, J. S., Muehllehner, G., & Lewitt, R. M. (1988) · IEEE Transactions on Medical Imaging · doi:10.1109/42.3925 · Cited by 107
A performance study of 3D reconstruction algorithms for positron emission tomography
Defrise, M., Geissbühler, A., & Townsend, D. W. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/3/001 · Cited by 45
Self-citation
Cited by
High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner
Qi, J., Leahy, R. M., Cherry, S. R., Chatziioannou, A., & Farquhar, T. H. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/027 · Cited by 635
Super-Resolution in Medical Imaging
Greenspan, H. (2008) · The Computer Journal · doi:10.1093/comjnl/bxm075 · Cited by 564
Fully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536
Self-citationDeep learning for tomographic image reconstruction
Wang, G., Ye, J. C., & De Man, B. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-020-00273-z · Cited by 531
New, faster, image-based scatter correction for 3D PET
Watson, C. C. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873020 · Cited by 519
Metadata
- Authors
- Defrise, M., Kinahan, P. E., Townsend, D. W., Michel, C., Sibomana, M., & Newport, D. F.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1997-04
- Volume
- 16
- Issue
- 2
- Pages
- 145-158
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2146892597
- Cited by
- 758
- References
- 17
- FWCI
- 20.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.