The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
The intravenous route to blood glucose control
Abstract
This article discusses closed-loop blood glucose regulation algorithms that use the intravenous route for insulin delivery to insulin-dependent diabetic patients. Classical control methods and advanced algorithms using implicit knowledge or explicit models (empirical, fundamental, or "gray-box") of the diabetic patient are examined. Current research on characterizing patient variability is presented, in the context of a model predictive controller able to adjust to changes in patient glucose and insulin sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bergman, R. N., Phillips, L. S., & Cobelli, C. (1981) · Journal of Clinical Investigation · doi:10.1172/jci110398 · Cited by 1,640 · cited 1×
“An extended version of the Bergman “minimal model” [23], including insulin antibody binding, was studied by Furler, et al.”
MethodGerich, J. E., Langlois, M., Noacco, C., Karam, J. H., & Forsham, P. H. (1973) · Science · doi:10.1126/science.182.4108.171 · Cited by 688
SIMON, C., BRANDENBERGER, G., & FOLLENIUS, M. (1987) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-64-4-669 · Cited by 147
Research works printed but not linked: 50
- 1992, Ashcroft FM and Ashcroft SJH: Insulin: Molecular Biology to Pathology
- 1993, N Engl J Med, 329, 977, 10.1056/NEJM199309303291401 · DOI · Paper page
- 1996, Diabetes, 45, 1289, 10.2337/diab.45.10.1289 · DOI · Paper page
- 10.2337/diacare.3.2.351 · doi:10.2337/diacare.3.2.351
- 10.2165/00003495-199142020-00004 · DOI
- 10.2337/diacare.13.9.955 · DOI
- Cohen, 1993, New disposable electronic micropump for parenteral drug delivery, 151
- 10.1007/BF02221686 · DOI
- Nishida, 1995, Development of a ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane, 2-methacryloyloxyethylphosphorylcholine-co-n-butyl methacrylate, Med Prog Technol 21:, 91
- Preidel, 1991, An electrocatalytic glucose sensor for in-vivo application, Biomed Instrum Technol 25:, 215
- 10.1055/s-0028-1093841 · DOI · Paper page
- Clemens, 1979, Feedback control dynamics for glucose controlled insulin infusion system, Med Prog Technol, 6, 91
- 10.2337/diab.23.5.389 · DOI · Paper page
- 10.1109/TBME.1981.324661 · DOI
- 10.1109/TBME.1976.324639 · DOI
- 10.2337/diabetes.26.7.663 · DOI
- 10.1111/j.1445-5994.1977.tb03687.x · DOI
- Clemens, 1977, Continuous blood glucose analysis and feedback control dynamics for glucose controlled insulin infusion (artificial beta-cell), 45
- Clemens, 1977, The development of biostator, a glucose controlled insulin infusion system (GCIIS), Horm Metab Res Suppl 7:, 22
- Fischer, 1978, Derivation and experimental proof of a new algorithm for the artificial ß-cell based on the individual analysis of the physiological insulin-glucose relationship, Endokrinologie, 71, 65
- 10.1007/BF02442800 · DOI
- 10.2337/diacare.8.6.553 · DOI
- Chisolm, 1978, A semi-closed loop computer-assisted insulin infusion system, Med J Aust, 141, 784, 10.5694/j.1326-5377.1984.tb132950.x · doi:10.5694/j.1326-5377.1984.tb132950.x
- 10.1016/0169-2607(90)90107-K · DOI
- 10.1109/TBME.1987.326068 · DOI
- 10.1109/TBME.1985.325500 · DOI
- 10.1016/0169-2607(90)90103-G · doi:10.1016/0169-2607(90)90103-g
- 10.1109/ACC.1995.529356 · DOI
- 10.1109/ACC.1997.609690 · doi:10.1109/acc.1997.609690
- 10.1109/ACC.1995.529355 · doi:10.1109/acc.1995.529355
- 10.1109/10.245631 · DOI
- 10.1007/BF02465181 · doi:10.1007/bf02465181
- Kikuchi, 1978, Homeostat to control blood glucose level, 541
- Kikuchi, 1980, Adaptive control system of blood glucose regulation, Proc MEDINFO 80, 96
- 10.1109/10.18755 · DOI
- 10.1080/01969729108902267 · doi:10.1080/01969729108902267
- 10.1080/00207178908953512 · DOI
- 10.1109/10.68209 · DOI · Paper page
- 10.1109/10.740877 · DOI · Paper page
- 10.1021/ie00004a018 · DOI · Paper page
- 10.1016/0005-1098(89)90002-2 · DOI · Paper page
- 10.23919/ACC.1993.4792877 · doi:10.23919/acc.1993.4792877
- 10.1109/TBME.1983.325203 · DOI
- 10.2337/diab.43.11.1365 · DOI
- 10.1152/ajpendo.1995.269.6.E1115 · DOI
- 10.2337/diabetes.48.3.445 · DOI
- Gelb, 1974, Applied Optimal Estimation.
- 10.1007/978-3-662-01632-9 · DOI
- 10.1016/0141-5425(92)90058-S · DOI · Paper page
- Morari, 1989, Robust Process Control
Cited by
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Makroglou, A., Li, J., & Kuang, Y. (2006) · Applied Numerical Mathematics · doi:10.1016/j.apnum.2005.04.023 · Cited by 367
Bequette, B. W. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.28 · Cited by 270
A critical review of mathematical models and data used in diabetology
Boutayeb, A., & Chetouani, A. (2006) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-5-43 · Cited by 126
Metadata
- Authors
- Parker, R. S., Doyle, F. J., & Peppas, N. A.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2001
- Volume
- 20
- Issue
- 1
- Pages
- 65-73
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2004575876
- Cited by
- 236
- References
- 3
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The intravenous route to blood glucose control. https://app.cochat.ai/papers/10.1109/51.897829
- The paper
- Parker, R. S., Doyle, F. J., & Peppas, N. A. (2001). The intravenous route to blood glucose control. IEEE Engineering in Medicine and Biology Magazine. https://doi.org/10.1109/51.897829
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.