The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Landmark matching via large deformation diffeomorphisms
Abstract
This paper describes the generation of large deformation diffeomorphisms /spl phi/:/spl Omega/=[0,1]/sup 3//spl rlhar2//spl Omega/ for landmark matching generated as solutions to the transport equation d/spl phi/(x,t)/dt=/spl nu/(/spl phi/(x,t),t),t/spl isin/[0,1] and /spl phi/(x,0)=x, with the image map defined as /spl phi/(/spl middot/,1) and therefore controlled via the velocity field /spl nu/(/spl middot/,t),t/spl isin/[0,1]. Imagery are assumed characterized via sets of landmarks {x/sub n/, y/sub n/, n=1, 2, ..., N}. The optimal diffeomorphic match is constructed to minimize a running smoothness cost /spl par/L/spl nu//spl par//sup 2/ associated with a linear differential operator L on the velocity field generating the diffeomorphism while simultaneously minimizing the matching end point condition of the landmarks. Both inexact and exact landmark matching is studied here. Given noisy landmarks x/sub n/ matched to y/sub n/ measured with error covariances /spl Sigma//sub n/, then the matching problem is solved generating the optimal diffeomorphism /spl phi//spl circ/(x,1)=/spl int//sub 0//sup 1//spl nu//spl circ/(/spl phi//spl circ/(x,t),t)dt+x where /spl nu//spl circ/(/spl middot/)argmin/sub /spl nu/(/spl middot/)//spl int//sub 1//sup 1//spl int//sub /spl Omega///spl par/L/spl nu/(x,t)/spl par//sup 2/dxdt +/spl Sigma//sub n=1//sup N/[y/sub n/-/spl phi/(x/sub n/,1)]/sup T//spl Sigma//sub n//sup -1/[y/sub n/-/spl phi/(x/sub n/,1)]. Conditions for the existence of solutions in the space of diffeomorphisms are established, with a gradient algorithm provided for generating the optimal flow solving the minimum problem. Results on matching two-dimensional (2-D) and three-dimensional (3-D) imagery are presented in the macaque monkey.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distributed hierarchical processing in the primate cerebral cortex
Felleman, D. J., & Van Essen, D. C. (1991) · Cerebral Cortex · doi:10.1093/cercor/1.1.1 · Cited by 7,783
Spline Models for Observational Data.
Muller, H.-G., & Wahba, G. (1991) · Journal of the American Statistical Association · doi:10.2307/2290434 · Cited by 4,928
Morphometric Tools for Landmark Data: Geometry and Biology
Bookstein, F. L. (1992) · Cambridge University Press eBooks · doi:10.1017/cbo9780511573064 · Cited by 4,365
Spline Models for Observational Data
Wahba, G. (1990) · doi:10.1137/1.9781611970128 · Cited by 4,184
Deterministic and Stochastic Optimal Control
Fleming, W., & Rishel, R. (1975) · Springer eBooks · doi:10.1007/978-1-4612-6380-7 · Cited by 2,733
An Introduction to Differentiable Manifolds and Riemannian Geometry
(1975) · Pure and Applied Mathematics · doi:10.1016/s0079-8169(08)x6065-9 · Cited by 1,778
Deformable templates using large deformation kinematics
Christensen, G. E., Rabbitt, R. D., & Miller, M. I. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.536892 · Cited by 1,142
Self-citationComputational anatomy: an emerging discipline
Grenander, U., & Miller, M. I. (1998) · Quarterly of Applied Mathematics · doi:10.1090/qam/1668732 · Cited by 623
Self-citationRepresentations of Knowledge in Complex Systems
Grenander, U., & Miller, M. I. (1994) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1994.tb02000.x · Cited by 603
Self-citationMathematical textbook of deformable neuroanatomies.
Miller, M. I., Christensen, G. E., Amit, Y., & Grenander, U. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.24.11944 · Cited by 462
Self-citation
Cited by
Yushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.015 · Cited by 8,868
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
AVANTS, B., EPSTEIN, C., GROSSMAN, M., & GEE, J. (2008) · Medical Image Analysis · doi:10.1016/j.media.2007.06.004 · Cited by 5,669
Unbiased average age-appropriate atlases for pediatric studies
Fonov, V., Evans, A. C., Botteron, K., Almli, C. R., McKinstry, R. C., & Collins, D. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.033 · Cited by 2,290
VoxelMorph: A Learning Framework for Deformable Medical Image Registration
Balakrishnan, G., Zhao, A., Sabuncu, M. R., Guttag, J., & Dalca, A. V. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2897538 · Cited by 2,174
Diffeomorphic demons: Efficient non-parametric image registration
Vercauteren, T., Pennec, X., Perchant, A., & Ayache, N. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.040 · Cited by 1,592
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“The advantage of this framework, known as Large Deformation Di eomorphic Metric Mapping (LDDMM), is that it allows for the de nition of a distance between images or sets of points [70, 71].”
BackgroundA spatially unbiased atlas template of the human cerebellum
Diedrichsen, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.056 · Cited by 986
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Wang, H., Dong, L., O'Daniel, J., Mohan, R., Garden, A. S., Ang, K. K., Kuban, D. A., Bonnen, M., Chang, J. Y., & Cheung, R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/12/011 · Cited by 610
A review of multimodal image matching: Methods and applications
Jiang, X., Ma, J., Xiao, G., Shao, Z., & Guo, X. (2021) · Information Fusion · doi:10.1016/j.inffus.2021.02.012 · Cited by 532
Unsupervised Learning of Probabilistic Diffeomorphic Registration for Images and Surfaces
Dalca, A. V., Balakrishnan, G., Guttag, J., & Sabuncu, M. R. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.07.006 · Cited by 467
On the Metrics and Euler-Lagrange Equations of Computational Anatomy
Miller, M. I., Trouvé, A., & Younes, L. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.092101.125733 · Cited by 438
Self-citationDRAMMS: Deformable registration via attribute matching and mutual-saliency weighting
Ou, Y., Sotiras, A., Paragios, N., & Davatzikos, C. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.07.002 · Cited by 407
Consistent landmark and intensity-based image registration
Johnson, H. J., & Christensen, G. E. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009381 · Cited by 399
Vaillant, M., & Glaunès, J. (2005) · Lecture Notes in Computer Science · doi:10.1007/11505730_32 · Cited by 380
A Review of Geometric Transformations for Nonrigid Body Registration
Holden, M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.904691 · Cited by 369
Geodesic Shooting for Computational Anatomy
Miller, M. I., Trouvé, A., & Younes, L. (2006) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-005-3624-0 · Cited by 366
Self-citationGholipour, A., Rollins, C. K., Velasco-Annis, C., Ouaalam, A., Akhondi-Asl, A., Afacan, O., Ortinau, C. M., Clancy, S., Limperopoulos, C., Yang, E., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-00525-w · Cited by 363
Results of a Multi-Institution Deformable Registration Accuracy Study (MIDRAS)
Brock, K. K. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.06.031 · Cited by 358
Statistics on diffeomorphisms via tangent space representations
Vaillant, M., Miller, M. I., Younes, L., & Trouvé, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.023 · Cited by 215
Self-citationMielke, M. M., Haughey, N. J., Bandaru, V. V. R., Schech, S., Carrick, R., Carlson, M. C., Mori, S., Miller, M. I., Ceritoglu, C., Brown, T., et al. (2010) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2010.03.014 · Cited by 170
Self-citationThree-dimensional diffusion tensor microimaging for anatomical characterization of the mouse brain
Aggarwal, M., Mori, S., Shimogori, T., Blackshaw, S., & Zhang, J. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22426 · Cited by 90
The diffeomorphometry of temporal lobe structures in preclinical Alzheimer's disease
Miller, M. I., Younes, L., Ratnanather, J. T., Brown, T., Trinh, H., Postell, E., Lee, D. S., Wang, M.-C., Mori, S., O'Brien, R., et al. (2013) · NeuroImage: Clinical · doi:10.1016/j.nicl.2013.09.001 · Cited by 88
Self-citationSelemon, L. D., Ceritoglu, C., Ratnanather, J. T., Wang, L., Harms, M. P., Aldridge, K., Begović, A., Csernansky, J. G., Miller, M. I., & Rakic, P. (2013) · Journal of Comparative Neurology · doi:10.1002/cne.23217 · Cited by 41
Self-citationLandmark‐guided region‐based spatial normalization for functional magnetic resonance imaging
He, H., & Razlighi, Q. R. (2022) · Human Brain Mapping · doi:10.1002/hbm.25865 · Cited by 7
Metadata
- Authors
- Joshi, S. C., & Miller, M. I.
- Venue
- IEEE Transactions on Image Processing
- Published
- 2000
- Volume
- 9
- Issue
- 8
- Pages
- 1357-1370
- ISSN
- 1057-7149 (ISSN-L)
- OpenAlex
- W2006302620
- Cited by
- 501
- References
- 26
- FWCI
- 10.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.