A surgically-implanted intramuscular electrode for an implantable neuromuscular stimulation system
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
An intramuscular electrode has been developed for use with an implantable neuromuscular stimulator. In vitro tests indicate that the electrode will maintain a stable position within the muscle, but is capable of being removed intact. When tested in a buffered saline environment at the maximum stimulation parameters (0.4 /spl mu/C/mm/sup 2//phase), there was no corrosion of the stimulating surface. In vivo evaluations were conducted, in which four sets of 4 intramuscular electrodes and 4 epimysial electrodes, were surgically implanted in the forelimb of 4 dogs. Each set was connected to an implanted neuromuscular stimulator. All but 1 of the 16 intramuscular electrodes operated properly throughout the study, producing responses functionally indistinguishable from epimysial electrodes. One electrode fractured due to improper surgical placement. After removal, some pitting corrosion was observed in 2 of the 15 retrieved intramuscular electrodes, possibly due to minute surface defects resulting from the electrode manufacturing process.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modulation of Muscle Force by Recruitment During Intramuscular Stimulation
Crago, P. E., Peckham, P. H., & Thrope, G. B. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326592 · Cited by 216
Self-citationRecruitment properties of monopolar and bipolar epimysial electrodes
Grandjean, P. A., & Mortimer, J. T. (1986) · Annals of Biomedical Engineering · doi:10.1007/bf02364648 · Cited by 134
Imbalanced biphasic electrical stimulation: Muscle tissue damage
Scheiner, A., Mortimer, J. T., & Roessmann, U. (1990) · Annals of Biomedical Engineering · doi:10.1007/bf02364157 · Cited by 117
Cited by
Functional Electrical Stimulation for Neuromuscular Applications
Peckham, P. H., & Knutson, J. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140103 · Cited by 784
Self-citationNeuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529
Stimulus waveforms for selective neural stimulation
Grill, W. M., & Mortimer, J. T. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.395310 · Cited by 280
Smith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
Self-citationPolasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142
Self-citation
Metadata
- Authors
- Memberg, W. D., Peckham, P. H., & Keith, M. W.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1994-06
- Volume
- 2
- Issue
- 2
- Pages
- 80-91
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2135957241
- Cited by
- 111
- References
- 3
- FWCI
- 0.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A surgically-implanted intramuscular electrode for an implantable neuromuscular stimulation system. https://app.cochat.ai/papers/10.1109/86.313149
- The paper
- Memberg, W. D., Peckham, P. H., & Keith, M. W. (1994). A surgically-implanted intramuscular electrode for an implantable neuromuscular stimulation system. IEEE Transactions on Rehabilitation Engineering. https://doi.org/10.1109/86.313149
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.