Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
A minimal set of muscles (8 to 16) were identified as candidates for implantation in a clinical system to provide walking function to individuals with complete paraplegia using functional electrical stimulation (FES). Three subjects with complete motor and sensory paraplegia had percutaneous intramuscular electrodes implanted in all major muscles controlling the trunk, hips, knees, and ankles. Stimulation patterns for walking with FES were generated for different sets of eight and 16 muscles. The quality and repeatability of the resulting gait produced by walking patterns consisting of various combinations of muscles were determined. Most eight-channel stimulation patterns resulted in scissoring or insufficient hip flexion, preventing forward progression. One eight-channel system allowed a maximum speed of 0.1 m/s with a cadence of 22 steps/min and a stride length less than 0.3 m. Improved walking performance was observed with 16 channels of stimulation. This ranged from slow step- to gait at 0.1 m/s to smooth reciprocal gait at 0.5 m/s. In all three subjects, the favored combination of 16 channels included erector spinae for trunk extension; gluteus maximus, posterior portion of adductor magnus and hamstrings for hip extension; tensor fasciae latae and either sartorius or iliopsoas for hip flexion; vastus lateralis/intermedius for knee extension; and tibialis anterior/peroneous longus for ankle dorsiflexion. In one subject the 16-channel FES system provided repeatable day-to-day gait averaging 0.4 m/s, 58 steps/min and a stride length at 0.8 m. A maximum repeatable walking distance with 16 channels was 34 m. Multiple 34-m trials were possible with minimal rests between walks. Fatigue of both the hip extensors and upper body was a limiting factor. The selection of target muscles for implantation is critical to the performance of FES systems. This study provides guidelines to muscle selection for walking with FES based on objective measures of gait performance. The findings indicate that a 16-channel FES system for total implantation is feasible for repeatable short distance, independent, walker-support walking in paraplegia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smith, B., Peckham, P. H., Keith, M. W., & Roscoe, D. D. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325979 · Cited by 281 · cited 1×
“Implantable systems available for clinical application are generally limited to eight channels of stimulation [ 14 ].”
BackgroundFunctional electrical stimulation for walking in paraplegia.
Marsolais, E. B., & Kobetic, R. (1987) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198769050-00014 · Cited by 259
Self-citationSynthesis of paraplegic gait with multichannel functional neuromuscular stimulation
Kobetic, R., & Marsolais, E. B. (1994) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.313148 · Cited by 165 · cited 5×
“Our fatigue data shows that no significant fatigue occurs during the short 8 m walks in hip flexors [9] and extensors [ 8 ], while during long 34 m walks a reduction of hip extension moment by approximately 30% can be expected [8].”
BackgroundMethodSelf-citationKralj, A. R., Bajd, T., Turk, R., Krajnik, J., & Benko, H. (1983) · PubMed · Cited by 159
Solomonow, M., Baratta, R. V., Hirokawa, S., Rightor, N., Walker, W., Beaudette, P., Shoji, H., & D'Ambrosia, R. D. (1989) · Orthopedics · doi:10.3928/0147-7447-19891001-06 · Cited by 141
The Use of a Four-Channel Electrical Stimulator as an Ambulatory Aid for Paraplegic Patients
Bajd, T., Kralj, A. R., Turk, R., Benko, H., & Šega, J. (1983) · Physical Therapy · doi:10.1093/ptj/63.7.1116 · Cited by 130
Holle, J., Frey, M., Gruber, H., Kern, H., Stöhr, H., & Thoma, H. (1984) · Orthopedics · doi:10.3928/0147-7447-19840701-09 · Cited by 89
Design and clinical application of a double helix electrode for functional electrical stimulation
Scheiner, A., Polando, G., & Marsolais, E. B. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293216 · Cited by 67 · cited 1×
“A major factor limiting practical use of the percutaneous system is the difficulty of implanting and maintaining percutaneous electrode system [ 13 ].”
MethodSelf-citationBiomechanical and physiological evaluation of FES-activated paraplegic patients.
Isakov, E., Mizrahi, J., & Najenson, T. (1986) · PubMed · Cited by 57
Borges, G., Ferguson, K., & Kobetic, R. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32113 · Cited by 33
Self-citation
Cited by
Functional Electrical Stimulation for Neuromuscular Applications
Peckham, P. H., & Knutson, J. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140103 · Cited by 784
Kobetic, R., Sharma, M., Triolo, R. J., Uhlir, J. P., Bieri, C., Wibowo, M., Polando, G., Marsolais, E. B., Davis, J. A., & Ferguson, K. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808942 · Cited by 155
Self-citationGustafson, K. J., Pinault, G. C. J., Neville, J. J., Syed, I., Jr, J. A. D., Jean-Claude, J., & Triolo, R. J. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.08.0097 · Cited by 107
Self-citation“Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves”
Christie, B. P., Freeberg, M., Memberg, W. D., Pinault, G. J. C., Hoyen, H. A., Tyler, D. J., & Triolo, R. J. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0285-3 · Cited by 97
“Additionally, walking speed with neural stimulation is reported to be slower than normal [45, 46] and therefore strong plantarflexion may not be essential in today’s lower extremity neural prostheses.”
BackgroundSelf-citationIntramuscular fat and physical performance at the Framingham Heart Study
Therkelsen, K. E., Pedley, A., Hoffmann, U., Fox, C. S., & Murabito, J. M. (2016) · AGE · doi:10.1007/s11357-016-9893-2 · Cited by 77
Functional Electrical Stimulation For Walking In Paraplegia: 17-Year Follow-Up Of 2 Cases
Agarwal, S., Kobetic, R., Nandurkar, S., & Marsolais, E. B. (2003) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.2003.11753666 · Cited by 49
Self-citationBijak, M., Mayr, W., Girsch, W., Lanmüller, H., Unger, E., Stöhr, H., Thoma, H., & Plenk, H. (2001) · Artificial Organs · doi:10.1046/j.1525-1594.2001.025006467.x · Cited by 8
Metadata
- Authors
- Kobetic, R., Triolo, R. J., & Marsolais, E. B.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1997-03
- Volume
- 5
- Issue
- 1
- Pages
- 23-29
- ISSN
- 1063-6528 (ISSN-L)
- 1558-0024
- OpenAlex
- W2113261286
- Cited by
- 185
- References
- 11
- FWCI
- 2.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.