Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia

Kobetic, R., Triolo, R.J., Marsolais, E.B. · 1997 · IEEE Transactions on Rehabilitation Engineering
Cited by 185

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

A minimal set of muscles (8 to 16) were identified as candidates for implantation in a clinical system to provide walking function to individuals with complete paraplegia using functional electrical stimulation (FES). Three subjects with complete motor and sensory paraplegia had percutaneous intramuscular electrodes implanted in all major muscles controlling the trunk, hips, knees, and ankles. Stimulation patterns for walking with FES were generated for different sets of eight and 16 muscles. The quality and repeatability of the resulting gait produced by walking patterns consisting of various combinations of muscles were determined. Most eight-channel stimulation patterns resulted in scissoring or insufficient hip flexion, preventing forward progression. One eight-channel system allowed a maximum speed of 0.1 m/s with a cadence of 22 steps/min and a stride length less than 0.3 m. Improved walking performance was observed with 16 channels of stimulation. This ranged from slow step- to gait at 0.1 m/s to smooth reciprocal gait at 0.5 m/s. In all three subjects, the favored combination of 16 channels included erector spinae for trunk extension; gluteus maximus, posterior portion of adductor magnus and hamstrings for hip extension; tensor fasciae latae and either sartorius or iliopsoas for hip flexion; vastus lateralis/intermedius for knee extension; and tibialis anterior/peroneous longus for ankle dorsiflexion. In one subject the 16-channel FES system provided repeatable day-to-day gait averaging 0.4 m/s, 58 steps/min and a stride length at 0.8 m. A maximum repeatable walking distance with 16 channels was 34 m. Multiple 34-m trials were possible with minimal rests between walks. Fatigue of both the hip extensors and upper body was a limiting factor. The selection of target muscles for implantation is critical to the performance of FES systems. This study provides guidelines to muscle selection for walking with FES based on objective measures of gait performance. The findings indicate that a 16-channel FES system for total implantation is feasible for repeatable short distance, independent, walker-support walking in paraplegia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/86.559346

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Kobetic, R., Triolo, R. J., & Marsolais, E. B.
Venue
IEEE Transactions on Rehabilitation Engineering
Published
1997-03
Volume
5
Issue
1
Pages
23-29
ISSN
  • 1063-6528 (ISSN-L)
  • 1558-0024
OpenAlex
W2113261286
Cited by
185
References
11
FWCI
2.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.