Tissue response to chronically stimulated implanted epimysial and intramuscular electrodes
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Twenty-four epimysial and 16 intramuscular electrodes were implanted in five adult dogs for periods ranging from 11 to 50 months. Chronic stimulation was applied to half of the electrodes for eight weeks near the end of the implantation period. The tissue response was rated by the amount and appearance of the fibrous tissue and inflammatory cells seen in the capsule lining the region of the electrode. The encapsulation tissues were composed primarily of collagen and fibroblasts and some macrophages and few other inflammatory cells. The epimysial electrodes exhibited more variation between and within electrodes, but had more of the better scores than the intramuscular electrodes. No difference in the distribution of scores was measured between the control and stimulated groups for the epimysial electrodes. While the scores for the intra-muscular electrodes varied very little, variance was sufficient to indicate a trend for poorer ratings with the application of chronic stimulation. Fibrous capsules were generally thinner under the epimysial electrodes than around the intramuscular electrodes. For both electrode types, the thickness was not correlated with the application or level of chronic stimulation. Thickness was shown to be positively correlated to the degree of loss of the sutures used to anchor the epimysial electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192
Self-citationRecruitment properties of monopolar and bipolar epimysial electrodes
Grandjean, P. A., & Mortimer, J. T. (1986) · Annals of Biomedical Engineering · doi:10.1007/bf02364648 · Cited by 134
Intramuscular electrical stimulation: Tissue damage
Mortimer, J. T., Kaufman, D., & Roessmann, U. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02364479 · Cited by 123
Cited by
Smith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
“The epimysial electrode [1] and intramuscular electrode [13] used in conjunction with an implantable stimulator have been demonstrated to provide suitable long term performance in vivo [ 15 ], [16].”
Self-citationWang, J., Wang, H., Thakor, N. V., & Lee, C. (2019) · ACS Nano · doi:10.1021/acsnano.9b00140 · Cited by 177
Kobetic, R., Sharma, M., Triolo, R. J., Uhlir, J. P., Bieri, C., Wibowo, M., Polando, G., Marsolais, E. B., Davis, J. A., & Ferguson, K. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808942 · Cited by 155
Polasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142
“The mean thresholds for muscle-based electrodes ranged from 78 to 164 nC with standard deviations ranging from 5 to 166 nC [29].”
InfluentialSelf-citationImplanted Neuroprosthesis for Restoring Arm and Hand Function in People With High Level Tetraplegia
Memberg, W. D., Polasek, K. H., Hart, R. L., Bryden, A. M., Kilgore, K. L., Nemunaitis, G. A., Hoyen, H. A., Keith, M. W., & Kirsch, R. F. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.01.028 · Cited by 137
Self-citationThe foreign body response to the Utah Slant Electrode Array in the cat sciatic nerve
Christensen, M. B., Pearce, S. M., Ledbetter, N. M., Warren, D. J., Clark, G. A., & Tresco, P. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.010 · Cited by 135
Gustafson, K. J., Pinault, G. C. J., Neville, J. J., Syed, I., Jr, J. A. D., Jean-Claude, J., & Triolo, R. J. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.08.0097 · Cited by 107
Durability of implanted electrodes and leads in an upper-limb neuroprosthesis
Kilgore, K. L., Peckham, P. H., Keith, M. W., Montague, F. W., Hart, R. L., Gazdik, M. M., Bryden, A. M., Snyder, S. A., & Stage, T. G. (2003) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2003.11.0457 · Cited by 85
“The encapsulation is similar to what we have observed in the dog model [10], consisting of a 0.”
BackgroundMethodSelf-citationUhlir, J. P., Triolo, R. J., Davis, J. A., & Bieri, C. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827224 · Cited by 44
“All of the volunteers in this investigation were part of a larger study to evaluate a fully implanted FNS system for standing and transfers in persons with SCI [4].”
BackgroundInfluentialNormann, R. A., Dowden, B. R., Frankel, M. A., Wilder, A. M., Hiatt, S. D., Ledbetter, N. M., Warren, D. A., & Clark, G. A. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026019 · Cited by 37
“These include surface electrodes [1, 2], epimysial electrodes [3], electrodes that are implanted within the central nervous systems [4, 5], peripheral nerve stimulating electrodes [6–8], and intrafascicular electrodes [9–13].”
BackgroundIntraoperative evaluation of the spiral nerve cuff electrode on the femoral nerve trunk
Polasek, K. H., Schiefer, M. A., Pinault, G. C. J., Triolo, R. J., & Tyler, D. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066005 · Cited by 33
Metadata
- Authors
- Akers, J. M., Peckham, P. H., Keith, M. W., & Merritt, K.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1997-06
- Volume
- 5
- Issue
- 2
- Pages
- 207-220
- ISSN
- 1063-6528 (ISSN-L)
- 1558-0024
- OpenAlex
- W2163310646
- Cited by
- 77
- References
- 3
- FWCI
- 0.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.