Coordinated, multi-joint, fatigue-resistant feline stance produced with intrafascicular hind limb nerve stimulation
Open accessAbstract
The production of graceful skeletal movements requires coordinated activation of multiple muscles that produce torques around multiple joints. The work described herein is focused on one such movement, stance, that requires coordinated activation of extensor muscles acting around the hip, knee and ankle joints. The forces evoked in these muscles by external stimulation all have a complex dependence on muscle length and shortening velocities, and some of these muscles are biarticular. In order to recreate sit-to-stand maneuvers in the anesthetized feline, we excited the hind limb musculature using intrafascicular multielectrode stimulation (IFMS) of the muscular branch of the sciatic nerve, the femoral nerve and the main branch of the sciatic nerve. Stimulation was achieved with either acutely or chronically implanted Utah Slanted Electrode Arrays (USEAs) via subsets of electrodes (1) that activated motor units in the extensor muscles of the hip, knee and ankle joints, (2) that were able to evoke large extension forces and (3) that manifested minimal coactivation of the targeted motor units. Three hind limb force-generation strategies were investigated, including sequential activation of independent motor units to increase force, and interleaved or simultaneous IFMS of three sets of six or more USEA electrodes that excited the hip, knee and ankle extensors. All force-generation strategies evoked stance, but the interleaved IFMS strategy also reduced muscle fatigue produced by repeated sit-to-stand maneuvers compared with fatigue produced by simultaneous activation of different motor neuron pools. These results demonstrate the use of interleaved IFMS as a means to recreate coordinated, fatigue-resistant multi-joint muscle forces in the unilateral hind limb. This muscle activation paradigm could provide a promising neuroprosthetic approach for the restoration of sit-to-stand transitions in individuals who are paralyzed by spinal cord injury, stroke or disease.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Recent penetrating neural interface applications require a greater number of electrodes (>60) to achieve complex neuromodulation or neurophysiological goals.
“Recent penetrating neural interface applications are requiring a greater number of electrodes (>60) to achieve complex neuromodulation [9,10,16] or neurophysiological [8] goals.”
From A new high-density (25 electrodes/mm<sup>2</sup>) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures (2013) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · see citing works
The effects of length and stimulus rate on tension in the isometric cat soleus muscle
Rack, P. M. H., & Westbury, D. R. (1969) · The Journal of Physiology · doi:10.1113/jphysiol.1969.sp008923 · Cited by 1,144 · see citing works
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · see citing works
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S. T., Spence, A. J., Isaacson, M. S., Craighead, H. G., Turner, J. N., & Shain, W. G. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 798 · see citing works
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792 · see citing works
Connecting cortex to machines: recent advances in brain interfaces
Donoghue, J. P. (2002) · Nature Neuroscience · doi:10.1038/nn947 · Cited by 720 · see citing works
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · see citing works
The cat step cycle: Hind limb joint angles and muscle lengths during unrestrained locomotion
Goslow, G. E., Reinking, R. M., & Stuart, D. G. (1973) · Journal of Morphology · doi:10.1002/jmor.1051410102 · Cited by 622 · see citing works
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488 · see citing works
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 470 · cited 2× · see citing works
“These include surface electrodes [1, 2], epimysial electrodes [3], electrodes that are implanted within the central nervous systems [4, 5], peripheral nerve stimulating electrodes [6–8], and intrafascicular electrodes [9–13].”
BackgroundFunctionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 1× · see citing works
“These include surface electrodes [1, 2], epimysial electrodes [3], electrodes that are implanted within the central nervous systems [4, 5], peripheral nerve stimulating electrodes [6–8], and intrafascicular electrodes [9–13].”
BackgroundReconstructing the Engram: Simultaneous, Multisite, Many Single Neuron Recordings
Nicolelis, M. A. L., Ghazanfar, A. A., Faggin, B. M., Votaw, S. V., & Oliveira, L. M. O. (1997) · Neuron · doi:10.1016/s0896-6273(00)80295-0 · Cited by 376 · see citing works
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 358 · cited 1× · see citing works
“Excitation overlap between pairs of electrodes was quantified using a refractory technique [17, 37] where two 0.”
MethodSelf-citationBiran, R., Martin, D. C., & Tresco, P. A. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31138 · Cited by 336 · see citing works
Isometric force production by motor units of extensor digitorum communis muscle in man
Monster, A. W., & Chan, H. (1977) · Journal of Neurophysiology · doi:10.1152/jn.1977.40.6.1432 · Cited by 320 · see citing works
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 305 · see citing works
Self-citationLong-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301 · see citing works
Self-citationA multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234 · see citing works
Self-citationSelective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208 · see citing works
Carlson‐Kuhta, P., Trank, T. V., & Smith, J. L. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.79.4.1687 · Cited by 188 · see citing works
Histopathological evaluation of materials implanted in the cerebral cortex
Stensaas, S. S., & Stensaas, L. J. (1978) · Acta Neuropathologica · doi:10.1007/bf00689766 · Cited by 177 · see citing works
Position-sensing technologies for movement analysis in stroke rehabilitation
Zheng, H., Black, N. D., & Harris, N. D. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344720 · Cited by 165 · see citing works
A floating metal microelectrode array for chronic implantation
Musallam, S., Bak, M. J., Troyk, P. R., & Andersen, R. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.09.005 · Cited by 135 · see citing works
Otto, K. J., Johnson, M. D., & Kipke, D. R. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862530 · Cited by 132 · see citing works
Sensitivity and selectivity of intraneural stimulation using a silicon electrode array
Rutten, W. L. C., van Wier, H. J., & Put, J. H. M. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76386 · Cited by 129 · see citing works
New functional electrical stimulation approaches to standing and walking
Mushahwar, V. K., Jacobs, P. L., Normann, R. A., Triolo, R. J., & Kleitman, N. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/s05 · Cited by 123 · see citing works
Self-citationEquine Post‐anesthetic Lameness A Retrospective Study
Richey, M., Holland, M., McGrath, C. J., Dodman, N. H., MARSHALL, D. B., Court, M. H., Norman, W. M., & Seeler, D. C. (1990) · Veterinary Surgery · doi:10.1111/j.1532-950x.1990.tb01216.x · Cited by 122 · see citing works
A technique to prevent dural adhesions to chronically implanted microelectrode arrays
Maynard, E. M., Fernández, E., & Normann, R. A. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00159-x · Cited by 102 · see citing works
Self-citationDavis, J. A., Triolo, R. J., Uhlir, J. P., Bieri, C., Rohde, L., Lissy, D. A., & Kukke, S. N. (2001) · PubMed · Cited by 99 · see citing works
McDonnall, D., Clark, G. A., & Normann, R. A. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.828425 · Cited by 98 · see citing works
Self-citationSmith, J. L., Carlson‐Kuhta, P., & Trank, T. V. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.79.4.1702 · Cited by 98 · see citing works
Electrical stimulation providing functional use of paraplegic patient muscles.
Kralj, A. R., Bajd, T., & Turk, R. (1980) · PubMed · Cited by 95 · see citing works
A Wireless Integrated Circuit for 100-Channel Charge-Balanced Neural Stimulation
Thurgood, B., Warren, D. J., Ledbetter, N. M., Clark, G. A., & Harrison, R. R. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2032268 · Cited by 93 · see citing works
Self-citationTissue response to potential neuroprosthetic materials implanted subdurally
Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90103-7 · Cited by 92 · see citing works
Stieglitz, T., Ruf, H. H., Gross, M., Schüettler, M., & Meyer, J.-U. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00019-2 · Cited by 77 · see citing works
Tissue response to chronically stimulated implanted epimysial and intramuscular electrodes
Akers, J. M., Peckham, P. H., Keith, M. W., & Merritt, K. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.593301 · Cited by 77 · see citing works
Strain and force transducers used in human and veterinary tendon and ligament biomechanical studies
Ravary‐Plumioën, B., Pourcelot, P., Bortolussi, C., Konieczka, S., & Crevier‐Denoix, N. (2004) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.01.008 · Cited by 73 · see citing works
Yoshida, K., & Horch, K. (1993) · Annals of Biomedical Engineering · doi:10.1007/bf02368649 · Cited by 69 · see citing works
Selective motor unit recruitment via intrafascicular multielectrode stimulation
McDonnall, D., Clark, G. A., & Normann, R. A. (2004) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y04-047 · Cited by 53 · see citing works
Self-citationBiocompatibility of Fixation Materials in the Brain
Mofid, M. M., Thompson, R. C., Pardo, C. A., Manson, P. N., & Kolk, C. A. V. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199707000-00003 · Cited by 50 · see citing works
(2000) · PubMed · Cited by 50 · see citing works
The functional consequences of chronic, physiologically effective intracortical microstimulation
Parker, R., Davis, T. S., House, P. A., Normann, R. A., & Greger, B. E. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53815-4.00010-8 · Cited by 47 · see citing works
Self-citationTrank, T. V., Chen, C., & Smith, J. L. (1996) · Journal of Neurophysiology · doi:10.1152/jn.1996.76.4.2316 · Cited by 46 · see citing works
Fatigue in mammalian skeletal muscle stimulated under computer control
Wise, A. K., Morgan, D. L., Gregory, J. E., & Proske, U. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.1.189 · Cited by 31 · see citing works
Graupe, D. (2002) · Neurological Research · doi:10.1179/016164102101200302 · Cited by 26 · see citing works
Adaptive change in electrically stimulated muscle: A framework for the design of clinical protocols
Salmons, S. (2009) · Muscle & Nerve · doi:10.1002/mus.21497 · Cited by 26 · see citing works
Frankel, M. A., Dowden, B. R., Mathews, V. J., Normann, R. A., Clark, G. A., & Meek, S. G. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2123920 · Cited by 25 · see citing works
Self-citationICFEM 2000. Third IEEE International Conference on Formal Engineering Methods
(2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867869 · Cited by 20 · see citing works
Selective and Graded Recruitment of Cat Hamstring Muscles With Intrafascicular Stimulation
Dowden, B. R., Wilder, A. M., Hiatt, S. D., Normann, R. A., Brown, N. A. T., & Clark, G. A. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2011988 · Cited by 19 · see citing works
Self-citationAutomated Stimulus-Response Mapping of High-Electrode-Count Neural Implants
Wilder, A. M., Hiatt, S. D., Dowden, B. R., Brown, N. A. T., Normann, R. A., & Clark, G. A. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2029494 · Cited by 16 · see citing works
Self-citationDowden, B. R., Frankel, M. A., Normann, R. A., & Clark, G. A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016006 · Cited by 11 · see citing works
Self-citationNerve cuffs for nerve repair and regeneration
Hoffer, J. A., & Kallesøe, K. (2000) · Progress in brain research · doi:10.1016/s0079-6123(00)28012-6 · Cited by 9 · see citing works
Intraoperative testing of selectivity of spiral nerve cuff electrodes
Polasek, K. H., Hoyen, H. A., Kirsch, R. F., & Tyler, D. J. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404154 · Cited by 2 · see citing works
Flagged first, then by citations
1 of the 54 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- [18]Dowden BR Non-invasive method for selection of electrodes and stimulus parameters for FES applications with intrafascicular arrays J Neural Eng 2012 9 1 016006 22173566
Cited by
Sorted by citations
Neural interfaces for the brain and spinal cord—restoring motor function
Andrew, J. O., & Zimmermann, J. B. (2012) · Nature Reviews Neurology · doi:10.1038/nrneurol.2012.219 · Cited by 254 · see citing works
Long-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes
Wurth, S., Capogrosso, M., Raspopovic, S., Gandar, J., Federici, G., Kinany, N., Cutrone, A., Piersigilli, A., Pavlova, N., Guiet, R., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.014 · Cited by 176 · see citing works
Wark, H. A. C., Sharma, R., Mathews, K. S., Fernandez, E., Yoo, J., Christensen, B., Tresco, P., Rieth, L., Solzbacher, F., Normann, R. A., et al. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045003 · Cited by 148 · see citing works
Self-citationWang, J., Wang, H., He, T., He, B., Thakor, N. V., & Lee, C. (2019) · Advanced Science · doi:10.1002/advs.201900149 · Cited by 137 · see citing works
Optical Stimulation of Neurons
C. Thompson, A., R. Stoddart, P., & Jansen, E. D. (2015) · Current Molecular Imaging · doi:10.2174/2211555203666141117220611 · Cited by 105 · see citing works
Providing a sense of touch to prosthetic hands
Nghiem, B. T., Sando, I. C., Gillespie, R. B., McLaughlin, B. L., Gerling, G. J., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S. (2015) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0000000000001289 · Cited by 104 · see citing works
Interfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98 · see citing works
Sharpe, A., & Andrew, J. O. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016005 · Cited by 76 · see citing works
Intrafascicular stimulation of monkey arm nerves evokes coordinated grasp and sensory responses
Ledbetter, N. M., Ethier, C., Oby, E. R., Hiatt, S. D., Wilder, A. M., Ko, J. H., Agnew, S. P., Miller, L. E., & Clark, G. A. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00688.2011 · Cited by 69 · see citing works
Self-citationWark, H. A. C., Mathews, K. S., Normann, R. A., & Fernandez, E. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046027 · Cited by 54 · see citing works
Self-citationBruns, T. M., Wagenaar, J., Bauman, M. J., Gaunt, R. A., & Weber, D. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026020 · Cited by 54 · see citing works
Downey, R. J., Cheng, T.-H., Bellman, M. J., & Dixon, W. E. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2427658 · Cited by 48 · see citing works
Characterization of a 3D optrode array for infrared neural stimulation
Abaya, T. V. F., Diwekar, M., Blair, S., Tathireddy, P., Rieth, L. W., Clark, G. A., & Solzbacher, F. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002200 · Cited by 48 · see citing works
Self-citationDowney, R. J., Cheng, T.-H., Bellman, M. J., & Dixon, W. E. (2016) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2016.2543699 · Cited by 39 · see citing works
Trout, M. A., Harrison, A. T., Brinton, M. R., & George, J. A. (2023) · Scientific Reports · doi:10.1038/s41598-023-30545-8 · Cited by 38 · see citing works
Brain-controlled muscle stimulation for the restoration of motor function
Éthier, C., & Miller, L. E. (2014) · Neurobiology of Disease · doi:10.1016/j.nbd.2014.10.014 · Cited by 38 · see citing works
Exploration of Hand Grasp Patterns Elicitable Through Non-Invasive Proximal Nerve Stimulation
Shin, H., Watkins, Z., & Hu, X. (2017) · Scientific Reports · doi:10.1038/s41598-017-16824-1 · Cited by 29 · see citing works
Deep-tissue light delivery via optrode arrays
Abaya, T. V. F., Diwekar, M., Blair, S., Tathireddy, P., Rieth, L. W., & Solzbacher, F. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.1.015006 · Cited by 22 · see citing works
Frankel, M. A., Mathews, V. J., Clark, G. A., Normann, R. A., & Meek, S. G. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00414 · Cited by 17 · see citing works
Self-citationTracking control of a human limb during asynchronous neuromuscular electrical stimulation
Downey, R. J., Cheng, T.-H., & Dixon, W. E. (2013) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2013.6759872 · Cited by 16 · see citing works
Activation of Superficial and Deep Finger Flexors Through Transcutaneous Nerve Stimulation
Shin, H., Hawari, M. A., & Hu, X. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3041669 · Cited by 14 · see citing works
The impact of synchronous versus asynchronous electrical stimulation in artificial vision
Moleirinho, S., Whalen, A. J., Fried, S. I., & Pezaris, J. S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abecf1 · Cited by 14 · see citing works
Effects of Synchronous Electrode Pulses on Neural Recruitment During Multichannel Microstimulation
Hokanson, J., Gaunt, R. A., & Weber, D. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-31247-2 · Cited by 13 · see citing works
Dowden, B. R., Frankel, M. A., Normann, R. A., & Clark, G. A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016006 · Cited by 11 · see citing works
Self-citationElicited upper limb motions through transcutaneous cervical spinal cord stimulation
Zheng, Y., & Hu, X. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab8f6f · Cited by 11 · see citing works
Thalamic Visual Prosthesis Project
Kyada, M. J., Killian, N. J., & Pezaris, J. S. (2016) · Springer eBooks · doi:10.1007/978-3-319-41876-6_14 · Cited by 10 · see citing works
Switched tracking control of a human limb during asynchronous neuromuscular electrical stimulation
Downey, R. J., Cheng, T.-H., Bellman, M. J., & Dixon, W. E. (2015) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2015.7172038 · Cited by 9 · see citing works
Eladly, A., del Valle, J., Minguillón, J., Mercadal, B., Becerra-Fajardo, L., Navarro, X., & Ivorra, A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba99e · Cited by 7 · see citing works
Thomas, W., Zuniga, S. A., Sondh, I., Leber, M., Solzbacher, F., Lenarz, T., Lim, H. H., Warren, D. J., Rieth, L. W., & Adams, M. E. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1308663 · Cited by 7 · see citing works
Self-citationEvaluation of Pneumatic Insertion Stability of Utah Slanted Electrode Arrays in Rat Sciatic Nerve
Thomas, W. M., Leber, M., Crew, J., & Warren, D. J. (2022) · 2022 44th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871237 · Cited by 5 · see citing works
Self-citationKoppaka, S. (2013) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 4 · see citing works
Cavalcanti, L. M., Thomas, W., Warren, D. J., & Mathews, V. J. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3530924 · Cited by 2 · see citing works
Self-citationPilot Performance of a Chronic Intraneural Auditory Neuroprosthesis in Felines
Thomas, W., Gurgel, R. K., & Warren, D. J. (2023) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner52421.2023.10123798 · Cited by 1 · see citing works
Self-citationHokanson, J. (2014) · D-Scholarship@Pitt (University of Pittsburgh)
Computer-assisted approaches to intrafascicular multielectrode stimulation
Wilder, A. M. (2014) · J. Willard Marriott Library · doi:10.26053/0h-t4ec-pq00
Self-citationBecerra-Fajardo, L. (2016) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
The Dynamic Shift of Neuron Excitability Observed with Enveloped High Frequency StimulationPreprint
Wang, J., Wang, H., Thow, X. Y., & Thakor, N. V. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1812.01179
- Authors
- Normann, R. A., Dowden, B. R., Frankel, M. A., Wilder, A. M., Hiatt, S. D., Ledbetter, N. M., Warren, D. A., & Clark, G. A.
- Affiliations
- University of Utah (US)
- Corresponding author
- Normann, R A
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2012-03-14
- Volume
- 9
- Issue
- 2
- Pages
- 026019
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC3377012
- OpenAlex
- W2001566012
- Cited by
- 37
- References
- 54
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 2 · 2022: 1 · 2021: 1 · 2020: 3 · 2019: 1 · 2018: 2 · 2017: 2 · 2016: 4 · 2015: 3 · 2014: 7 · 2013: 4 · 2012: 4
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Research Institute, Georgia Institute of Technology
- Georgia Institute of Technology
- Fundación Ramón Areces
- National Institutes of Health (5r01ns064318-02)
- Defense Advanced Research Projects Agency (N66001, N66001-06-C-8005)
- National Institute of Neurological Disorders and Stroke (R01-NS064318, R01NS039677, R01-NS064318-01A1)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Pathology and Forensic Medicine › Spinal Cord Injury Research
- Keywords
- sit-to-stand, sciatic nerve, femoral nerve, muscle fatigue, neuroprosthetics, spinal cord injury, stroke
- MeSH terms
- Algorithms, Anesthesia, Animals, Biomechanical Phenomena, Cats, Computer Simulation, Electric Stimulation, Electrodes, Electrodes, Implanted, Femoral Nerve, Hindlimb, Joints, Motor Neurons, Muscle Contraction, Recruitment, Neurophysiological, Sciatic Nerve, Walking, Muscle, Skeletal, Muscle Fatigue, Neural Prostheses
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review