The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Real-time EEG analysis with subject-specific spatial patterns for a brain-computer interface (BCI)
Abstract
Electroencephalogram (EEG) recordings during right and left motor imagery allow one to establish a new communication channel for, e.g., patients with amyotrophic lateral sclerosis. Such an EEG-based brain-computer interface (BCI) can be used to develop a simple binary response for the control of a device. Three subjects participated in a series of on-line sessions to test if it is possible to use common spatial patterns to analyze EEG in real time in order to give feedback to the subjects. Furthermore, the classification accuracy that can be achieved after only three days of training was investigated. The patterns are estimated from a set of multichannel EEG data by the method of common spatial patterns and reflect the specific activation of cortical areas. By construction, common spatial patterns weight each electrode according to its importance to the discrimination task and suppress noise in individual channels by using correlations between neighboring electrodes. Experiments with three subjects resulted in an error rate of 2, 6 and 14% during on-line discrimination of left- and right-hand motor imagery after three days of training and make common spatial patterns a promising method for an EEG-based brain-computer interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural networks for pattern recognition
(1994) · Choice Reviews Online · doi:10.5860/choice.31-5500 · Cited by 18,538
Neural Networks for Pattern Recognition
Bishop, C. M. (1995) · doi:10.1093/oso/9780198538493.001.0001 · Cited by 12,287
Introduction to Statistical Pattern Recognition
(1990) · Elsevier eBooks · doi:10.1016/c2009-0-27872-x · Cited by 11,031
Optimal spatial filtering of single trial EEG during imagined hand movement
Ramoser, H., Muller-Gerking, J., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895946 · Cited by 2,457
Self-citationA spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Pfurtscheller, G., Stancák, A., & Neuper, C. (1996) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(96)00066-9 · Cited by 1,205
Self-citationMotor imagery activates primary sensorimotor area in humans
Pfurtscheller, G., & Neuper, C. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00889-6 · Cited by 1,051
Self-citationSpatial filter selection for EEG-based communication
McFarland, D. J., McCane, L. M., David, S. V., & Wolpaw, J. R. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00022-2 · Cited by 936
EEG-based discrimination between imagination of right and left hand movement
Pfurtscheller, G., Neuper, C., Flotzinger, D., & Pregenzer, M. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00080-1 · Cited by 904
Self-citationDesigning optimal spatial filters for single-trial EEG classification in a movement task
Müller-Gerking, J., Pfurtscheller, G., & Flyvbjerg, H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00038-8 · Cited by 846
Self-citation
Cited by
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080
Kushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Self-citationDeep learning for healthcare applications based on physiological signals: A review
Faust, O., Hagiwara, Y., Hong, T. J., Lih, O. S., & Acharya, U. R. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.04.005 · Cited by 1,026
Blankertz, B., Dornhege, G., Krauledat, M., Müller, K.-R., & Curio, G. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.051 · Cited by 946
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Neurophysiological predictor of SMR-based BCI performance
Blankertz, B., Sannelli, C., Halder, S., Hammer, E. M., Kübler, A., Müller, K.-R., Curio, G., & Dickhaus, T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.022 · Cited by 674
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
EEG dataset and OpenBMI toolbox for three BCI paradigms: an investigation into BCI illiteracy
Lee, M.-H., Kwon, O.-Y., Kim, Y.-J., Kim, H.-K., Lee, Y.-E., Williamson, J., Fazli, S., & Lee, S.-W. (2019) · GigaScience · doi:10.1093/gigascience/giz002 · Cited by 590
Current trends in Graz brain-computer interface (BCI) research
Pfurtscheller, G., Neuper, C., Guger, C., Harkam, W., Ramoser, H., Schlogl, A., Obermaier, B., & Pregenzer, M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847821 · Cited by 518
Self-citationBrain–Computer Interfaces Using Sensorimotor Rhythms: Current State and Future Perspectives
Yuan, H., & He, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2312397 · Cited by 492
Towards adaptive classification for BCI
Shenoy, P., Krauledat, M., Blankertz, B., Rao, R. P. N., & Müller, K.-R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/r02 · Cited by 438
The Berlin brain-computer Interface: accurate performance from first-session in BCI-naive subjects
Blankertz, B., Losch, F., Krauledat, M., Dornhege, G., Curio, G., & Muller, K.-R. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923152 · Cited by 338
Information transfer rate in a five-classes brain-computer interface
Obermaier, B., Neuper, C., Guger, C., & Pfurtscheller, G. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.948456 · Cited by 337
Self-citationPrediction of arm movement trajectories from ECoG-recordings in humans
Pistohl, T., Ball, T., Schulze-Bonhage, A., Aertsen, A., & Mehring, C. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.10.001 · Cited by 331
A New Discriminative Common Spatial Pattern Method for Motor Imagery Brain–Computer Interfaces
Thomas, K. P., Guan, C., Lau, C. T., Vinod, A. P., & Ang, K. K. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2026181 · Cited by 321
Neuper, C., Müller, G. R., Kübler, A., Birbaumer, N., & Pfurtscheller, G. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00387-5 · Cited by 317
Self-citationA Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Seperability of four-class motor imagery data using independent components analysis
Naeem, M., Brunner, C., Leeb, R., Graimann, B., & Pfurtscheller, G. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/003 · Cited by 295
Self-citationSelective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Continuous EEG classification during motor imagery-simulation of an asynchronous BCI
Townsend, G., Graimann, B., & Pfurtscheller, G. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827220 · Cited by 276
Self-citationDysarthria in amyotrophic lateral sclerosis: A review
Tomik, B., & Guiloff, R. J. (2010) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482960802379004 · Cited by 201
Stuck-at Fault Tolerance in RRAM Computing Systems
Xia, L., Huangfu, W., Tang, T., Yin, X., Chakrabarty, K., Xie, Y., Wang, Y., & Yang, H. (2018) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2017.2776980 · Cited by 177
A Collaborative Brain-Computer Interface for Improving Human Performance
Wang, Y., & Jung, T.-P. (2011) · PLoS ONE · doi:10.1371/journal.pone.0020422 · Cited by 147
Benefits of deep learning classification of continuous noninvasive brain–computer interface control
Stieger, J. R., Engel, S. A., Suma, D., & He, B. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0584 · Cited by 55
Metadata
- Authors
- Guger, C., Ramoser, H., & Pfurtscheller, G.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 2000
- Volume
- 8
- Issue
- 4
- Pages
- 447-456
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2136897104
- Cited by
- 383
- References
- 31
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.