Survey of DC-DC Non-Isolated Topologies for Unidirectional Power Flow in Fuel Cell Vehicles
Open accessThe DOI matches its Crossref record; 147 of the 147 references it cites were found in a registry or an index.
Abstract
The automobile companies are focusing on recent technologies such as growing Hydrogen (H2) and Fuel Cell (FC) Vehicular Power Train (VPT) to improve the Tank-To-Wheel (TTW) efficiency. Benefits, the lower cost, `Eco' friendly, zero-emission and high-power capacity, etc. In the power train of fuel cell vehicles, the DC-DC power converters play a vital role to boost the fuel cell stack voltage. Hence, satisfy the demand of the motor and transmission in the vehicles. Several DC-DC converter topologies have proposed for various vehicular applications like fuel cell, battery, and renewable energy fed hybrid vehicles etc. Most cases, the DC-DC power converters are viable and cost-effective solutions for FC-VPT with reduced size and increased efficiency. This article describes the state-of-the-art in unidirectional non-isolated DC-DC Multistage Power Converter (MPC) topologies for FC-VPT application. The paper presented the comprehensive review, comparison of different topologies and stated the suitability for different vehicular applications. This article also discusses the DC-DC MPC applications more specific to the power train of a small vehicle to large vehicles (bus, trucks etc.). Further, the advantages and disadvantages pointed out with the prominent features for converters. Finally, the classification of the DC-DC converters, its challenges, and applications for FC technology is presented in the review article as state-of-the-art in research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2001) · Springer eBooks · doi:10.1007/b100747 · Cited by 6,112
Yilmaz, M., & Krein, P. T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212917 · Cited by 3,118
Forouzesh, M., Siwakoti, Y. P., Gorji, S. A., Blaabjerg, F., & Lehman, B. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2652318 · Cited by 2,123 · cited 7×
“The coupled inductor is another solution to increase the voltage conversion ratio [65].”
BackgroundMethodSelf-citationThe state of the art of electric, hybrid, and fuel cell vehicles
Chan, C. C. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.892489 · Cited by 1,987 · cited 1×
“The output voltage of the fuel cell is few, and the number of stacking more fuel cell is not the optimal solution to increase the terminal voltage, to satisfy the demand of power train and luxurious electrical loads [19], [81].”
BackgroundModern electric, hybrid electric, and fuel cell vehicles fundamentals, theory, and design
Ehsani, M., Gao, Y., & Emadi, A. (2005) · Cited by 1,613
Electrical Machines and Drives for Electric, Hybrid, and Fuel Cell Vehicles
Zhu, Z. Q., & Howe, D. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2006.892482 · Cited by 1,547
Review of Nonisolated High-Step-Up DC/DC Converters in Photovoltaic Grid-Connected Applications
Li, W., & He, X. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049715 · Cited by 1,423 · cited 5×
“The power circuit of the converter discussed in [128], [144] shown in Fig.”
BackgroundMethodInfluentialAxelrod, B., Berkovich, Y., & Ioinovici, A. (2008) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2008.916403 · Cited by 1,379 · cited 4×
“In [109]–[113], ZETA DC-DC converter based on the diode assist capacitor derived.”
BackgroundMethodInfluentialThe state of the art of electric and hybrid vehicles
Chan, C. C. (2002) · Proceedings of the IEEE · doi:10.1109/5.989873 · Cited by 1,100
A review on the state-of-the-art technologies of electric vehicle, its impacts and prospects
Yong, J. Y., Ramachandaramurthy, V. K., Tan, K. M., & Mithulananthan, N. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.04.130 · Cited by 1,081
Self-citation
Cited by
Ali, A., H. H. Mousa, H., F. Shaaban, M., A. Azzouz, M., & S. A. Awad, A. (2024) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2023.000107 · Cited by 162
“[11] [16], [17] [18], [19] [20] [13], [21] [12], [22] Study in detail state-of-the-art EV charging topologies and PEC solutions for EV applications from the point of view of their groupings, configurations, control methods, and future research projections and their impacts on the power quality of…”
Metadata
- Authors
- Sagar Bhaskar, M., Ramachandaramurthy, V. K., Padmanaban, S., Blaabjerg, F., Ionel, D. M., Mitolo, M., & Almakhles, D.
- Venue
- IEEE Access
- Published
- 2020
- Volume
- 8
- Pages
- 178130-178166
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W3091637248
- Cited by
- 214
- References
- 147
- FWCI
- 9.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.