Artificial Intelligence-Driven Thermal Management in Electric Vehicle Traction Inverters: Cooling System Optimization and Real-Time Temperature Prediction
Open accessThe DOI matches its Crossref record; 2 of the 43 references it cites were found in a registry or an index, and 39 are not checked yet; none of the 10 sources its claims cite is checked for support yet.
Abstract
The accelerated adoption of electric vehicles (EVs) has intensified technical demands on traction inverters, particularly regarding power density, energy efficiency, and thermal management. Silicon Carbide (SiC) MOSFET modules, with their superior switching performance and thermal characteristics, offer significant advantages but introduce new thermal challenges due to their increased power density and compact packaging. The primary objective of this study is to enhance real-time thermal control and prediction in SiC-based dual traction inverters through the design and experimental validation of a high-performance cooling system integrated into a modular electric drive platform. Multiple cold plate configurations were evaluated using computational fluid dynamics (CFD) simulations, focusing on junction temperature, thermal uniformity, and pressure drop. To enable real-time thermal predictions, a reduced-order model (ROM) was derived from CFD data and combined with an artificial neural network (ANN) trained to estimate junction temperatures dynamically. The ANN was integrated into the inverter control system and supported by real-time sensor data, enabling continuous dynamic thermal monitoring during operation. The proposed approach offers a scalable and intelligent thermal management solution, supporting predictive maintenance and enhancing the reliability and efficiency of next-generation EV powertrains.
Checked 2026-11-23 · 39 references not checked yet
Overview
CoChat Summary
TL;DR
This paper designs a bio-inspired liquid-cooled cold plate for a SiC dual traction inverter and couples CFD, a reduced-order model, and an ANN to predict junction temperature in real time. Experimental HiL validation shows ANN junction-temperature errors below 3.5% and predictions within 1 s.
Key findings
- The bio-inspired cold plate, integrated into the inverter housing, achieved nominal CFD maximum temperatures of 72.81 °C for power module 2 and 66.98 °C for module 1, with intra-module variation of 2.98 °C and 5.34 °C, inter-module difference of 8.32 °C, and pressure drop of 51.58 mbar, meeting the 175 °C junction and 60 mbar pressure-drop targets.
- Under harsh conditions (65 °C inlet, 4 L/min, 3.4 kW total heat loss, 1.7 kW per module), the maximum junction temperature remained below 175 °C.
- The CFD-based ROM reduced simulation time from approximately 150 min to about 15 min on the same workstation, with prediction error below the 3.5% target; the ANN further reduced prediction to about 1 s while maintaining error below 3.5%.
- Experimental validation showed the ANN-estimated junction temperature at nominal conditions was 65.4 °C versus CFD 66.7 °C, a relative error of −3.1%; at 45 °C inlet, maximum relative error was −2.9%, and the ANN tracked dynamic thermal behavior during a light-load drive cycle.
Methods
- Multiple cold plate architectures were compared, and a final bio-inspired design with a single coolant inlet/outlet branching into semi-parallel internal channels was integrated into the dual SiC traction inverter housing; CFD used ANSYS Discovery/Fluent with approximately 13 million elements and 3 million nodes, SST k-ω turbulence model, and a 50% ethylene glycol-water coolant.
- A CFD-based ROM was built using snapshot methodology, POD, and 40 CFD snapshots across 10 design cycles; an ANN was trained in MATLAB on over 130 high-fidelity CFD and CFD-ROM results using a single hidden-layer feedforward backpropagation network with 20 neurons and the Levenberg-Marquardt algorithm.
- Experimental validation used the Open Vehicle Powertrain Platform HiL setup with dSPACE MicroLabBox and MATLAB/Simulink, with sensors for coolant inlet/outlet, power-module baseplate, integrated NTC MOSFET temperature, and flow rate; tests were performed on a single-side inverter under nominal conditions, at 45 °C inlet, and during a representative light-load drive cycle.
Limitations
- The paper states that detailed closed-loop control algorithm design is beyond scope, validation was performed on a single-side inverter, and future work is needed for transient dual-inverter scenarios and closed-loop thermal control.
- The paper states CFD simulations were steady-state and did not consider transient phenomena such as coolant flow-rate variations, coolant-temperature fluctuations, or dynamic load changes; it also notes inlet temperature could not be held perfectly constant due to TCU limitations.
- Evident from the text: the ANN was trained using the entire dataset without a separate validation or test split, and experimental thermal feedback was limited to the maximum reported T_mosfet and T_junction, whereas CFD resolved all three half-bridge circuits.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 1 Not valid · 7 Not checked · 55 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“while the inter-module temperature difference was 8.32 • C.”
§ Artificial Intelligence-Driven Thermal Management in Electric Vehicle Traction Inverters: Cooling System Optimization and Real-Time Temperature Prediction > A. CFD SIMULATION FRAMEWORK
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The resulting loss per switch is approximately 100 W.”
§ Artificial Intelligence-Driven Thermal Management in Electric Vehicle Traction Inverters: Cooling System Optimization and Real-Time Temperature Prediction > A. CFD SIMULATION FRAMEWORK
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“As a summary, the serial cold plate with microchannels ultimately provided the best balance between cooling performance, pressure drop, and manufacturability, making it the most promising candidate for integration into the dual traction inverter housing.”
§ Artificial Intelligence-Driven Thermal Management in Electric Vehicle Traction Inverters: Cooling System Optimization and Real-Time Temperature Prediction > 1) BASELINE DESIGN DEFINITION
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The heat dissipation, measured using temperature sensors at the coolant inlet and outlet, was approximately 800 W”
§ Artificial Intelligence-Driven Thermal Management in Electric Vehicle Traction Inverters: Cooling System Optimization and Real-Time Temperature Prediction > IV. REAL-TIME THERMAL MANAGEMENT: VALIDATION
plainSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Notably, the entire training process was completed approximately one second in the same workstation”
§ Artificial Intelligence-Driven Thermal Management in Electric Vehicle Traction Inverters: Cooling System Optimization and Real-Time Temperature Prediction > D. ANN-BASED PREDICTION
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
27 more claims
Create a free account to see all 63 claims and to verify the 8 references still open.
- It may state two separate claims as one. 27
- Probably not a substantial claim. 10
Citations
Cites
He, Z., Yan, Y., & Zhang, Z. (2021) · Energy · doi:10.1016/j.energy.2020.119223 · Cited by 869 · cited 1×
“These temperature-driven degradations are significant, with thermal factors accounting for approximately 55% of all power electronics failures [14], [15], [16], [17], [18].”
Semiconductor Power Devices: Physics, Characteristics, Reliability
Lutz, J., Schlangenotto, H., Scheuermann, U., & De Doncker, R. (2011) · Springer eBooks · doi:10.1007/978-3-642-11125-9 · Cited by 706
Inductors and Transformers for Power Electronics
Valchev, V. C., & Van den Bossche, A. (2018) · CRC Press eBooks · doi:10.1201/9781420027280 · Cited by 562 · cited 1×
“Assuming resistive conduction losses [38]: The total power loss of the MOSFET is the sum of the conduction and switching losses, given by The maximum allowable power dissipation is limited by the system’s thermal resistance, cooling capacity, and the acceptable temperature rise [39].”
Present Status and Future Trends in Electric Vehicle Propulsion Technologies
Rajashekara, K. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2259614 · Cited by 446
State of the art of high temperature power electronics
Buttay, C., Planson, D., Allard, B., Bergogne, D., Bevilacqua, P., Joubert, C., Lazar, M., Martin, C., Morel, H., Tournier, D., et al. (2011) · Materials Science and Engineering: B · doi:10.1016/j.mseb.2010.10.003 · Cited by 432 · cited 1×
“Although the SiC devices are theoretically capable of operating at junction temperatures exceeding 400 C, practical constraints related to packaging reliability currently limit commercial operation to approximately 175 C [12].”
Air cooled heat sink geometries subjected to forced flow: A critical review
Khattak, Z., & Ali, H. M. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.08.048 · Cited by 309 · cited 1×
“These temperature-driven degradations are significant, with thermal factors accounting for approximately 55% of all power electronics failures [14], [15], [16], [17], [18].”
Silicon carbide power MOSFETs: Breakthrough performance from 900 V up to 15 kV
Palmour, J. W., Cheng, L., Pala, V., Brunt, E. V., Lichtenwalner, D. J., Wang, G.-Y., Richmond, J., O'Loughlin, M., Ryu, S., Allen, S. T., et al. (2014) · 2014 IEEE 26th International Symposium on Power Semiconductor Devices & IC's (ISPSD) · doi:10.1109/ispsd.2014.6855980 · Cited by 300 · cited 1×
“Their appeal lies in several advantageous characteristics, including reduced conduction losses, lower on-resistance, faster switching speeds, higher breakdown voltage, and superior high-temperature operation [7], [8], [9], [10].”
Reliability and performance limitations in SiC power devices
Singh, R. (2006) · Microelectronics Reliability · doi:10.1016/j.microrel.2005.10.013 · Cited by 284
Reliability of Power Electronic Systems for EV/HEV Applications
Blaabjerg, F., Wang, H., Vernica, I., Liu, B., & Davari, P. (2021) · Proceedings of the IEEE · doi:10.1109/jproc.2020.3031041 · Cited by 249
Li, Z., Luo, H., Jiang, Y., Liu, H., Xu, L., Cao, K., Wu, H., Gao, P., & Liu, H. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.123612 · Cited by 243 · cited 1×
“These temperature-driven degradations are significant, with thermal factors accounting for approximately 55% of all power electronics failures [14], [15], [16], [17], [18].”
Research works printed but not linked: 1
- Artificial intelligenceaided thermal model considering cross-coupling effects. Y Zhang, Z Wang, H Wang, F Blaabjerg, 10.1109/TPEL.2020.2980240IEEE Trans. Power Electron. 3510Oct. 2020 · doi:10.1109/tpel.2020.2980240ieee
Cited by
Radhakrishnan, A., Prasad, R. V., Railis, D. J., Dinesh, R. S., & Prasad, B. D. (2026) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-026-15314-9 · Cited by 9
“Martin et al. [34] introduced AI and machine learning (ML) models to predict and optimize thermal management strategies in EVs, offering improvements in energy efficiency and battery lifespan.”
Bhoi, S. K., Chakraborty, S., Aghdaei, A., Mathew, A., Horn, T. D., Liebig, S., Albrecht, J., Abart, C., Doncker, R. W. D., & Hegazy, O. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3630790 · Cited by 7
Self-citationDesign Optimization of EV Drive Systems: Building the Next Generation of Automatic AI Platforms
Jiang, H., Wang, Y., Lei, G., Sun, X., & Zhu, J. (2026) · World Electric Vehicle Journal · doi:10.3390/wevj17010035 · Cited by 3
“Inverter optimization was extended for thermal management by integrating high-fidelity CFD modeling with artificial neural networks in [122].”
AI in the Adoption of Electric Vehicles: Advantages, Challenges and Future Outlook: A Review
AlZohbi, G., & Alradhi, N. (2026) · Premier journal of science. · doi:10.70389/pjs.100260 · Cited by 3
Prognostix-XAI: Interpretable Modeling of Mechanical Degradation Dynamics
Makesh, N. S., Naveenkumar, M., Kavitha, J., Amudieshwar, A., & Chankyan, T. (2026) · International Conference on Intelligent Data Communication Technologies and Internet of Things (IDCIoT) · doi:10.1109/idciot67589.2026.11455807 · Cited by 1
Metadata
- Authors
- Egin Martin, G., Verbrugge, B., Mahedi Hasan, M., El Baghdadi, M., Romano, C., & Hegazy, O.
- Affiliations
- MOBI-EPOWERS Research Group, ETEC Department, Vrije Universiteit Brussel (VUB), Brussels, Belgium
- Vrije Universiteit Brussel (BE)
- Ideas and Motion S.r.l., Cherasco, Italy
- Venue
- IEEE Access
- Published
- 2025
- Volume
- 13
- Pages
- 167632-167648
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W4414348261
- Semantic Scholar
- e59416dc325c5c8cda909300a53b7cd22e031661
- Cited by
- 8
- References
- 42
- Citations by year
- 2026: 8
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- IEEE Access (publishedVersion, cc-by-nc-nd)
- VUBIR (Vrije Universiteit Brussel) (submittedVersion, other-oa)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- HiEFFICIENT Project from the Electronic Components and Systems for European Leadership (ECSEL) Joint Undertaking (101007281)
- Flanders Make
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Keywords
- electric vehicle traction inverter, thermal management, cold plate design, junction temperature prediction, model reduction, artificial neural networks, real-time thermal monitoring, cooling system optimization, pressure drop, temperature uniformity, predictive maintenance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.