Cited by 16Analog and Mixed-Signal Circuit DesignNeuroscience and Neural EngineeringRadio Frequency Integrated Circuit Design

A pulse-width-adaptive active charge balancing circuit with pulse-insertion based residual charge compensation and quantization for electrical stimulation applications

Yao, Lei, Li, Peng, Je, Minkyu·2015·2015 IEEE Asian Solid-State Circuits Conference (A-SSCC)

Abstract

Charge balancing is an important task for the stimulators used in chronic electrical stimulation applications. In this paper, a pulse-width-adaptive (PWA) active charge balancing (ACB) circuit with pulse-insertion based residual charge compensation and quantization is proposed to fulfil this task. The proposed circuit dynamically adapts the pulse width (Tc) of counter phase (Φc) over a stimulation pulses train to achieve charge balancing. The adaptation step ΔTc is based on the quantized residual charge (Qres) of the initial stimulation pulse. Pulse insertion technique is used to quantize Qress and perform instant charge balancing after each stimulation pulse. The PWA ACB circuit mainly consists of an auxiliary pulse generator, residual voltage (Vres) monitoring and Qres quantization block, and a digital controller. A successive approximation (SA) algorithm is implemented in the digital controller for fast Tc searching. The proposed circuit is implemented in 0.18μm CMOS process with 24V LDMOS option, occupying a core area of 700μm by 150μm. The functionality and effectiveness of the circuit are verified through bench-top and animal experiments.

Integrity signals

Registry

Crossref · 10.1109/asscc.2015.7387478

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Pulse-width-adaptive charge balancing has been developed as a stand-alone solution or to operate in parallel with offset compensation to overcome high-frequency current spikes blocking neural signals or interfering with next stimulating pulses.

    “To overcome this, pulse-width-adaptive charge balancing has been developed as a stand-alone solution or to operate in parallel with offset compensation [147], [148].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Yao, L., Li, P., & Je, M.
Affiliations
Agency for Science, Technology and Research (SG)
Venue
2015 IEEE Asian Solid-State Circuits Conference (A-SSCC)
Publisher
IEEE
Published
2015-11
Pages
1-4
OpenAlex
W2244165710
Cited by
16
References
11
Citations by year
2025: 5 · 2024: 3 · 2023: 1 · 2021: 2 · 2020: 3 · 2019: 1 · 2018: 1
FWCI
0.64
Type
conference paper
Language
en
Open access
closed
Locations
IEEE Asian Solid-State Circuits Conference (A-SSCC) (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
Keywords
charge quantization, electrical stimulation, chronic stimulation, successive approximation algorithm, digital controller, 0.18 μm CMOS, LDMOS

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review