A pulse-width-adaptive active charge balancing circuit with pulse-insertion based residual charge compensation and quantization for electrical stimulation applications
Abstract
Charge balancing is an important task for the stimulators used in chronic electrical stimulation applications. In this paper, a pulse-width-adaptive (PWA) active charge balancing (ACB) circuit with pulse-insertion based residual charge compensation and quantization is proposed to fulfil this task. The proposed circuit dynamically adapts the pulse width (Tc) of counter phase (Φc) over a stimulation pulses train to achieve charge balancing. The adaptation step ΔTc is based on the quantized residual charge (Qres) of the initial stimulation pulse. Pulse insertion technique is used to quantize Qress and perform instant charge balancing after each stimulation pulse. The PWA ACB circuit mainly consists of an auxiliary pulse generator, residual voltage (Vres) monitoring and Qres quantization block, and a digital controller. A successive approximation (SA) algorithm is implemented in the digital controller for fast Tc searching. The proposed circuit is implemented in 0.18μm CMOS process with 24V LDMOS option, occupying a core area of 700μm by 150μm. The functionality and effectiveness of the circuit are verified through bench-top and animal experiments.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Pulse-width-adaptive charge balancing has been developed as a stand-alone solution or to operate in parallel with offset compensation to overcome high-frequency current spikes blocking neural signals or interfering with next stimulating pulses.
“To overcome this, pulse-width-adaptive charge balancing has been developed as a stand-alone solution or to operate in parallel with offset compensation [147], [148].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [147]
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · see citing works
Restoration of grasp following paralysis through brain-controlled stimulation of muscles
Ethier, C., Oby, E. R., Bauman, M. J., & Miller, L. E. (2012) · Nature · doi:10.1038/nature10987 · Cited by 485 · see citing works
Chen, W., Chiueh, H., Chen, T.-J., Ho, C.-L., Jeng, C., Ker, M., Lin, C., Huang, Y.-C., Chou, C.-W., Fan, T.-Y., et al. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284346 · Cited by 279 · see citing works
A Power-Efficient Wireless System With Adaptive Supply Control for Deep Brain Stimulation
Lee, H., Park, H., & Ghovanloo, M. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2266862 · Cited by 231 · see citing works
A 232-Channel Epiretinal Stimulator ASIC
Ortmanns, M., Rocke, A., Gehrke, M., & Tiedtke, H. J. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908693 · Cited by 225 · see citing works
Noorsal, E., Sooksood, K., Xu, H., Hornig, R., Becker, J., & Ortmanns, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2164667 · Cited by 212 · see citing works
An active approach for charge balancing in functional electrical stimulation.
Sooksood, K., Stieglitz, T., & Ortmanns, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2040277 · Cited by 170 · see citing works
Radiofrequency Applications to Dorsal Root Ganglia
Malik, K. M., Benzon, H. T., Warner, D. S., et al. (2008) · Anesthesiology · doi:10.1097/aln.0b013e318182c86e · Cited by 71 · see citing works
Chen, W., Chiueh, H., Chen, T.-J., Ho, C.-L., Jeng, C., Chang, S.-T., Ker, M., Lin, C., Huang, Y.-C., Chou, C.-W., et al. (2013) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2013.6487737 · Cited by 36 · see citing works
Yao, L., Zhao, J., Li, P., Xue, R.-F., Xu, Y. P., & Je, M. (2014) · IEEE Asian Solid-State Circuits Conference (A-SSCC) · doi:10.1109/asscc.2014.7008895 · Cited by 17 · see citing works
Self-citationPrecision control of pulse widths for charge balancing in functional electrical stimulation
Lo, Y., Hill, R., Chen, K., & Liu, W. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696225 · Cited by 17 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Butz, N., Taschwer, A., Nessler, S., Manoli, Y., & Kuhl, M. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2828823 · Cited by 70 · see citing works
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11 · see citing works
“To overcome this, pulse-width-adaptive charge balancing has been developed as a stand-alone solution or to operate in parallel with offset compensation [147], [148].”
- Authors
- Yao, L., Li, P., & Je, M.
- Affiliations
- Agency for Science, Technology and Research (SG)
- Venue
- 2015 IEEE Asian Solid-State Circuits Conference (A-SSCC)
- Publisher
- IEEE
- Published
- 2015-11
- Pages
- 1-4
- OpenAlex
- W2244165710
- Cited by
- 16
- References
- 11
- Citations by year
- 2025: 5 · 2024: 3 · 2023: 1 · 2021: 2 · 2020: 3 · 2019: 1 · 2018: 1
- FWCI
- 0.64
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE Asian Solid-State Circuits Conference (A-SSCC) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- charge quantization, electrical stimulation, chronic stimulation, successive approximation algorithm, digital controller, 0.18 μm CMOS, LDMOS
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review