Effects of filtering on multi-site photoplethysmography pulse waveform characteristics
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Multisite photoplethysmography (PPG) allows pulse waveforms collected simultaneously from different peripheral body sites to be investigated. PPG waveforms are site-dependent, comprising a pulsatile ('AC') component synchronized to each heart beat, superimposed on a slowly varying ('DC') baseline. Careful high pass filtering of the pulses is needed to reduce the dominant lower frequencies but without distorting pulse shape, and sufficient computer quantization levels to reliably reproduce the pulse. In this study pulses were measured from the right ear, thumb and great toe of 10 healthy adult subjects. Pulses were then filtered offline at cut-off frequencies between 0.05 to 1 Hz using a digital single pole high pass filter. The relationship between filter cut-off frequency on lower to higher frequency amplitudes, AC pulse amplitude relative to system noise, and visible pulse shape distortion were investigated. The ratio of low to high frequency amplitudes decreased with increasing cut-off frequency (highest at toe, lowest at ear). The AC pulse amplitude relative to system noise increased with increasing cut-off frequency (highest at thumb, lowest at toe). A qualitative visual inspection of the waveforms showed that pulse shape distortion was likely at cut-off frequencies greater than 0.2 Hz. A single pole high pass filter cut-off frequency of 0.15 Hz for multisite PPG measurements enables faithful pulse shape reproduction for subsequent cardiovascular modelling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589 · cited 1×
“Pulses were then filtered offline at cut-off frequencies between 0.05 to 1 Hz using a digital single pole high pass filter.”
MethodInfluentialSkin photoplethysmography — a review
Kamal, A. A. R., Harness, J. B., Irving, G., & Mearns, A. J. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90159-4 · Cited by 328 · cited 1×
“In this study pulses were measured from the right ear, thumb and great toe of 10 healthy adult subjects.”
MethodNitzan, M., Babchenko, A., Khanokh, B., & Landau, D. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/1/008 · Cited by 217 · cited 1×
“Careful high pass filtering of the pulses is needed to reduce the dominant lower frequencies but without distorting pulse shape, and sufficient computer quantization levels to reliably reproduce the pulse.”
BackgroundAllen, J., & Murray, A. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/306 · Cited by 202
Self-citationAge-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
Allen, J., & Murray, A. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001478 · Cited by 179 · cited 1×
“PPG waveforms are site-dependent, comprising a pulsatile (‘AC’) component synchronized to each heart beat, superimposed on a slowly varying (‘DC’) baseline.”
BackgroundSelf-citationAllen, J., Frame, J. R., & Murray, A. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/2/312 · Cited by 86
Low-frequency photoplethysmograph signals
Harness, J. B., & Marjanovic, D. Z. (1989) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/10/4/009 · Cited by 6
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“The choice of high pass filter cut-off frequency is particularly important and is often a design compromise; excessive filtering can distort the pulse shape but too little filtering can result in the quasi-DC component dominating over the AC pulse (Allen and Murray 2003, 2004).”
BackgroundSelf-citationGhamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 366
Hartmann, V., Liu, H., Chen, F., Qiu, Q., Hughes, S., & Zheng, D. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00198 · Cited by 173
Metadata
- Authors
- Allen, J., & Murray, A.
- Venue
- Computers in Cardiology, 2004
- Publisher
- IEEE
- Published
- 2005-07-13
- Pages
- 485-488
- ISSN
- 0276-6574 (ISSN-L)
- OpenAlex
- W1541229674
- Cited by
- 54
- References
- 7
- FWCI
- 1.55
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.