Quantitative comparison of photoplethysmographic waveform characteristics: Effect of measurement site
Open accessAbstract
Introduction: Photoplethysmography (PPG) has been widely used to assess cardiovascular function. However, few studies have comprehensively investigated the effect of measurement site on PPG waveform characteristics. This study aimed to provide a quantitative comparison on this. Methods: 36 healthy subjects participated in this study. For each subject, PPG signals were sequentially recorded for one minute from six different body sites (finger, wrist under (anatomically volar), wrist upper (dorsal), arm, earlobe, and forehead) under both normal and deep breathing patterns. For each body site under a certain breathing pattern, the mean amplitude was firstly derived from recorded PPG waveform which was then normalized to derive several waveform characteristics including the pulse peak time (Tp), dicrotic notch time (Tn), and the reflection index (RI). The effects of breathing pattern and measurement site on the waveform characteristics were finally investigated by the analysis of variance (ANOVA) with post-hoc multiple comparisons. Results: Under both breathing patterns, the PPG measurements from the finger achieved the highest percentage of analysable waveforms for extracting waveform characteristics. There were significant effects of breathing pattern on Tn and RI (larger Tn and smaller RI with deep breathing on average, both p<0.03). The effects of measurement site on mean amplitude, Tp, Tn, and RI were significant (all p<0.001). The key results were that, under both breathing patterns, the mean amplitude from finger PPG was significantly larger and its Tp and RI were significantly smaller than those from the other five sites (all p < 0.001, except p=0.04 for the Tp of ‘wrist under’), and Tn was only significantly larger than that from the earlobe (both p < 0.05). Conclusion: This study has quantitatively confirmed the effect of PPG measurement site on PPG waveform characteristics (including mean amplitude, Tp, Tn, and RI), providing scientific evidence for a better understanding the PPG waveform variations between different body sites.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Hartmann et al. determined that there is no statistically significant change in PPG amplitude as a function of age.
“Another study by Hartmann et al. determined that there is no statistically significant change in PPG amplitude as a function of age; however, this work featured 36 individuals ranging in age from only 33 to 58.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [95]
Dicrotic notch duration at the finger was not significantly different from measurements under the wrist and forehead, but was different from the earlobe, arm, and wrist.
“Dicrotic notch duration at the finger was not significantly different from measurements under the wrist and forehead, but was different from the earlobe, arm, and wrist.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [95]
Locations on the head and finger provide the greatest PPG amplitude.
“Overall, it has been found that locations on the head and finger provide the greatest PPG amplitude [95,145].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [95]
The finger yielded a significant peak point position, meaning a shorter systolic rising edge (p < 0.001 for all sites except under the wrist, which had p = 0.04).
“The finger yielded a significant peak point position, meaning a shorter systolic rising edge (p < 0.001 for all sites except under the wrist, which had p = 0.04).”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [95]
The finger was shown to have a significantly lower (p < 0.001) reflection index.
“Finally, the finger was shown to have a significantly lower (p < 0.001) reflection index.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [95]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206 · see citing works
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 567 · see citing works
Maeda, Y., Sekine, M., & Tamura, T. (2011) · Journal of Medical Systems · doi:10.1007/s10916-010-9505-0 · Cited by 203 · see citing works
Allen, J., & Murray, A. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/306 · Cited by 202 · see citing works
Charlton, P. H., Bonnici, T., Tarassenko, L., Alastruey, J., Clifton, D. A., Beale, R. J., & Watkinson, P. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa670e · Cited by 140 · see citing works
Toward Generating More Diagnostic Features from Photoplethysmogram Waveforms
Elgendi, M., Liang, Y., & Ward, R. K. (2018) · Diseases · doi:10.3390/diseases6010020 · Cited by 107 · see citing works
Photoplethysmogram (PPG) signal analysis and wavelet de-noising
Joseph, G., Joseph, A., Titus, G., Thomas, R. M., & Jose, D. (2014) · Annual International Conference on Emerging Research Areas and International Conference on Microelectronics, Communications and Renewable Energy · doi:10.1109/aicera.2014.6908199 · Cited by 93 · see citing works
Nilsson, L., Goscinski, T., Kalman, S., Lindberg, L. ‐., & Johansson, A. (2007) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2007.01375.x · Cited by 88 · see citing works
Finger and ear photoplethysmogram waveform analysis by fitting with Gaussians
Rubīns, U. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0406-z · Cited by 83 · see citing works
Variability of photoplethysmographyperipheral pulse measurementsat the ears, thumbs and toes
Allen, J., & Murray, A. (2000) · IEE Proceedings - Science Measurement and Technology · doi:10.1049/ip-smt:20000846 · Cited by 76 · see citing works
Probabilistic Estimation of Respiratory Rate from Wearable Sensors
Pimentel, M. A. F., Charlton, P. H., & Clifton, D. A. (2015) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-18191-2_10 · Cited by 61 · see citing works
Bentham, M., Stansby, G. P., & Allen, J. (2018) · Diseases · doi:10.3390/diseases6030081 · Cited by 60 · see citing works
Effects of filtering on multi-site photoplethysmography pulse waveform characteristics
Allen, J., & Murray, A. (2005) · Computers in cardiology · doi:10.1109/cic.2004.1442980 · Cited by 56 · see citing works
McKay, N. D., Griffiths, B., Maria, C. D., Hedley, S., Murray, A., & Allen, J. (2014) · Lara D. Veeken · doi:10.1093/rheumatology/keu196 · Cited by 32 · see citing works
Photoplethysmography: Analysis of the Pulse Oximeter Waveform
Alian, A. A., & Shelley, K. H. (2013) · Springer eBooks · doi:10.1007/978-1-4614-8557-5_19 · Cited by 30 · see citing works
Su, F., Li, Z., Sun, X., Han, N., Wang, L., & Luo, X. (2014) · Bio-Medical Materials and Engineering · doi:10.3233/bme-130801 · Cited by 29 · see citing works
Sun, S., Peeters, W. H., Bezemer, R., Long, X., Paulussen, I., Aarts, R. M., & Noordergraaf, G. J. (2018) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-018-0140-5 · Cited by 26 · see citing works
Multivariate classification of systemic vascular resistance using photoplethysmography
Lee, Q. Y., Chan, G. S. H., Redmond, S. J., Middleton, P. M., Steel, E., Malouf, P. J., Critoph, C., Flynn, G. M., O’Lone, E., & Lovell, N. H. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/8/008 · Cited by 24 · see citing works
Yuan, H., Memon, S. F., Newe, T., Lewis, E., & Leen, G. (2017) · Measurement · doi:10.1016/j.measurement.2017.10.060 · Cited by 22 · see citing works
Sharkey, E., Maria, C. D., Klinge, A., Murray, A., Zheng, D., O’Sullivan, J. J., & Allen, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aac76a · Cited by 20 · see citing works
Self-citationWang, A., Yang, L., Liu, C., Cui, J., Li, Y., Yang, X., Zhang, S., & Zheng, D. (2015) · BioMed Research International · doi:10.1155/2015/752570 · Cited by 19 · see citing works
Self-citationHernando, A., Peláez‐Coca, M. D., Lozano, M. T., Aiger, M., Gil, E., & Lázaro, J. M. (2017) · European Signal Processing Conference (EUSIPCO) · doi:10.23919/eusipco.2017.8081575 · Cited by 19 · see citing works
Estimation of respiratory rates based on photoplethysmographic measurements at the sternum
Chreiteh, S. S., Belhage, B., Hoppe, K., Branebjerg, J., Haahr, R. G., Duun, S., & Thomsen, E. V. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319898 · Cited by 9 · see citing works
Noninvasive Assistive Method to Diagnose Arterial Disease-Takayasu’s Arteritis
Lakshmanan, S., Chatterjee, D., & Manivannan, M. (2018) · Lecture notes in computational vision and biomechanics · doi:10.1007/978-3-319-71767-8_32 · Cited by 7 · see citing works
Peralta, E., Lázaro, J. M., Gil, E., Bail�n, R., & Marozas, V. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.205-286 · Cited by 7 · see citing works
A Reflectance Sensor Holder for PPG Measurements from the Chest
McNary, N. D., Finkelstein, C. E., & Claverie, T. H. (2017) · Cited by 1 · see citing works
Flagged first, then by citations
2 of the 28 references couldn’t be matched to a known paper.
Research works printed but not linked: 2
- Bahrain A. K. Ali M. A. M. Jaafar R. (2014). The significance change of PPG reflection index in left ventricular hypertrophy risk individual. Int. J. Sci. Eng. Res. 5 712– 717. Available at: https://pdfs.semanticscholar.org/a897/e9a879e5f869b037dcbac6a13e2d0fbed42e.pdf
- Qawqzeh Y. K. Reaz M. B. I. Ali M. A. M. (2010). The analysis of PPG contour in the assessment of atherosclerosis for erectile dysfunction subjects. WSEAS Trans. Biol. Biomed. 7 306– 315.
Cited by
Sorted by citations
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250 · see citing works
Recent advances in wearable sensors and portable electronics for sleep monitoring
Kwon, S., Kim, H., & Yeo, W.-H. (2021) · iScience · doi:10.1016/j.isci.2021.102461 · Cited by 209 · see citing works
A Review of Wearable Multi-Wavelength Photoplethysmography
Ray, D., Collins, T., Woolley, S., & Ponnapalli, P. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3121476 · Cited by 155 · see citing works
Scardulla, F., Cosoli, G., Spinsante, S., Poli, A., Iadarola, G., Pernice, R., Busacca, A., Pasta, S., Scalise, L., & D’Acquisto, L. (2023) · Measurement · doi:10.1016/j.measurement.2023.113150 · Cited by 120 · see citing works
Wearable Photoplethysmography for Cardiovascular Monitoring.
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · KTUePubl (Repository of Kaunas University of Technology) · doi:10.17863/cam.81148 · Cited by 113 · see citing works
Wearable Cuff-Less Blood Pressure Estimation at Home via Pulse Transit Time
Ganti, V. G., Carek, A. M., Nevius, B. N., Heller, J. A., Etemadi, M., & Inan, O. T. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3021532 · Cited by 101 · see citing works
Pankaj, Kumar, A., Komaragiri, R., & Kumar, M. (2021) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09597-4 · Cited by 84 · see citing works
XGBoost Regression of the Most Significant Photoplethysmogram Features for Assessing Vascular Aging
Shin, H. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3151091 · Cited by 78 · see citing works
Djeldjli, D., Bousefsaf, F., Maaoui, C., Bereksi-Reguig, F., & Pruski, A. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102242 · Cited by 74 · see citing works
Chee, M. W. L., Baumert, M., Scott, H., Cellini, N., Goldstein, C. A., Baron, K. G., Imtiaz, S. A., Penzel, T., & Kushida, C. A. (2025) · Sleep Medicine · doi:10.1016/j.sleep.2025.106506 · Cited by 73 · see citing works
Kwon, S., Hong, J., Choi, E.-K., Lee, B., Baik, C., Lee, E., Jeong, E.-R., Koo, B.-K., Oh, S., & Yi, Y. (2020) · Journal of Medical Internet Research · doi:10.2196/16443 · Cited by 65 · see citing works
Influence of mental stress on the pulse wave features of photoplethysmograms
Celka, P., Charlton, P. H., Farukh, B., Chowienczyk, P., & Alastruey, J. (2019) · Healthcare Technology Letters · doi:10.1049/htl.2019.0001 · Cited by 64 · see citing works
Mahmud, S., Ibtehaz, N., Khandakar, A. A., Rahman, M. S., Gonzales, A. J., Rahman, T., Hossain, M. S., Hossain, M. S. A., Faisal, M. A. A., Abir, F. F., et al. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104247 · Cited by 60 · see citing works
Cuffless Blood Pressure in clinical practice: challenges, opportunities and current limits.
Henry, B., Merz, M., Hoang, H., Abdulkarim, G., Wosik, J., & Schoettker, P. (2024) · Blood Pressure · doi:10.1080/08037051.2024.2304190 · Cited by 54 · see citing works
Zanelli, S., Ammi, M., Hallab, M., & El‐Yacoubi, M. A. (2022) · Sensors · doi:10.3390/s22134890 · Cited by 53 · see citing works
Liu, H., Allen, J., Khalid, S. G., Chen, F., & Zheng, D. (2021) · Physiological Measurement · doi:10.1088/1361-6579/ac0a34 · Cited by 50 · see citing works
Self-citationMoscato, S., Giudice, S. L., Massaro, G., & Chiari, L. (2022) · Sensors · doi:10.3390/s22155831 · Cited by 51 · see citing works
Nardelli, M., Vanello, N., Galperti, G., Greco, A., & Scilingo, E. P. (2020) · Sensors · doi:10.3390/s20113156 · Cited by 43 · see citing works
Pankaj, Kumar, A., Komaragiri, R., & Kumar, M. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.105081 · Cited by 42 · see citing works
Yen, C.-T., Chen, U.-H., Wang, G., & Chen, Z.-X. (2022) · Sensors · doi:10.3390/s22124452 · Cited by 40 · see citing works
Multifunctional skin-compliant wearable sensors for monitoring human condition applications
Maddirala, G., Searle, T., Wang, X., Alıcı, G., & Sencadas, V. (2022) · Applied Materials Today · doi:10.1016/j.apmt.2021.101361 · Cited by 40 · see citing works
Credico, A. D., Perpetuini, D., Izzicupo, P., Gaggi, G., Cardone, D., Filippini, C., Merla, A., Ghinassi, B., & Baldassarre, A. D. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.893374 · Cited by 34 · see citing works
Estimation of phase distortions of the photoplethysmographic signal in digital IIR filtering
Lapitan, D. G., Рогаткин, Д. А., Molchanova, E. A., & Tarasov, A. P. (2024) · Scientific Reports · doi:10.1038/s41598-024-57297-3 · Cited by 34 · see citing works
Wang, H., Wang, L., Sun, N., Yao, Y., Hao, L., Xu, L., & Greenwald, S. E. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2019.01563 · Cited by 36 · see citing works
Keller, M., Pelz, H., Perlitz, V., Zweerings, J., Roecher, E., Baqapuri, H. I., & Mathiak, K. (2020) · Psychophysiology · doi:10.1111/psyp.13594 · Cited by 33 · see citing works
Photoplethysmography in Normal and Pathological Sleep
Vulcan, R. S., André, S., & Bruyneel, M. (2021) · Sensors · doi:10.3390/s21092928 · Cited by 35 · see citing works
A Survey of Photoplethysmography and Imaging Photoplethysmography Quality Assessment Methods
Desquins, T., Bousefsaf, F., Pruski, A., & Maaoui, C. (2022) · Applied Sciences · doi:10.3390/app12199582 · Cited by 33 · see citing works
Advances in PPG Sensors Data Acquisition With Light-to-Digital Converters: A Review
Chettri, N., Aprile, A., Bonizzoni, E., & Malcovati, P. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3420170 · Cited by 29 · see citing works
Singstad, B.-J., Azulay, N., Bjurstedt, A., Bjørndal, S. S., Drageseth, M. F., Engeset, P., Eriksen, K., Gidey, M. Y., Granum, E. O., Greaker, M. G., et al. (2021) · Journal of Electrical Bioimpedance · doi:10.2478/joeb-2021-0012 · Cited by 29 · see citing works
A machine learning strategy for fast prediction of cardiac function based on peripheral pulse wave
Wang, S., Wu, D., Li, G., Song, X., Qiao, A., Li, R., Liu, Y., Anzai, H., & Liu, H. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106664 · Cited by 28 · see citing works
Self-citationThe Dicrotic Notch: Mechanisms, Characteristics, and Clinical Correlations
Abushouk, A. I., Kansara, T. M., Abdelfattah, O., Badwan, O. Z., Hariri, E. H., Chaudhury, P., & Kapadia, S. R. (2023) · Current Cardiology Reports · doi:10.1007/s11886-023-01901-x · Cited by 27 · see citing works
Bousefsaf, F., Djeldjli, D., Ouzar, Y., Maaoui, C., & Pruski, A. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104860 · Cited by 26 · see citing works
Ambient and wearable system for workers’ stress evaluation
Rescio, G., Manni, A., Caroppo, A., Ciccarelli, M., Papetti, A., & Leone, A. (2023) · Computers in Industry · doi:10.1016/j.compind.2023.103905 · Cited by 26 · see citing works
Finger and forehead PPG signal comparison for respiratory rate estimation
Hernando, A., Peláez‐Coca, M. D., Lozano, M. T., Lázaro, J. M., & Gil, E. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab3be0 · Cited by 25 · see citing works
van Es, V. A. A., Lopata, R. G. P., Scilingo, E. P., & Nardelli, M. (2023) · Sensors · doi:10.3390/s23031505 · Cited by 24 · see citing works
Wang, C.-F., Wang, T.-Y., Kuo, P.-H., Wang, H., Li, S.-Z., Lin, C., Chan, S.-C., Liu, T., Lo, Y., Lin, S.-H., et al. (2023) · Biosensors · doi:10.3390/bios13030321 · Cited by 24 · see citing works
External factors that affect the photoplethysmography waveforms
Pi, I., Pi, I., & Wu, W. (2021) · SN Applied Sciences · doi:10.1007/s42452-021-04906-9 · Cited by 21 · see citing works
Marzorati, D., Dorizza, A., Bovio, D., Salito, C., Mainardi, L. T., & Cerveri, P. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3148171 · Cited by 21 · see citing works
Tsai, P., Huang, C.-H., Guo, J.-W., Li, Y., Wu, A.-Y. A., Lin, H., & Wang, T. (2021) · Sensors · doi:10.3390/s21134315 · Cited by 20 · see citing works
Establishing best practices in photoplethysmography signal acquisition and processing
Charlton, P. H., Pilt, K., & Kyriacou, P. A. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac6cc4 · Cited by 23 · see citing works
Quality Assessment and Morphological Analysis of Photoplethysmography in Daily Life
Moscato, S., Palmerini, L., Palumbo, P., & Chiari, L. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.912353 · Cited by 20 · see citing works
An XGBoost-based model for assessment of aortic stiffness from wrist photoplethysmogram
Li, Y., Xu, Y., Ma, Z., Ye, Y., Gao, L., & Sun, Y. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107128 · Cited by 19 · see citing works
Mahmud, S., Chowdhury, M. E. H., Serkan Kiranyaz, B., Tapotee, M. I., Saha, P., Tahir, A., Khandakar, A. A., & Alqahtani, A. (2024) · Expert Systems with Applications · doi:10.1016/j.eswa.2024.123167 · Cited by 18 · see citing works
Prada, E. J. A., & García, J. F. C. (2024) · Sensors · doi:10.3390/s24227193 · Cited by 18 · see citing works
Multi-point sensing organic light-emitting diode display based mobile cardiovascular monitor
Kim, C., Lee, K. J., Kim, J., Yang, D., Lee, H., Moon, G., Kim, Y., Cho, D., Bae, K. S., Kim, G.-H., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-56915-6 · Cited by 17 · see citing works
Cardiodiagnostics Based on Photoplethysmographic Signals
Georgieva-Tsaneva, G. N., Gospodinova, E. P., & Cheshmedzhiev, K. (2022) · Diagnostics · doi:10.3390/diagnostics12020412 · Cited by 17 · see citing works
Validating Photoplethysmography (PPG) data for driver drowsiness detection
Amidei, A., Fallica, P. G., Sabrina Conoci, A., & Pavan, P. (2021) · IEEE International Workshop on Metrology for Automotive (MetroAutomotive) · doi:10.1109/metroautomotive50197.2021.9502865 · Cited by 16 · see citing works
Mather, J. D., Hayes, L. D., Mair, J. L., & Sculthorpe, N. F. (2024) · Frontiers in Digital Health · doi:10.3389/fdgth.2024.1326511 · Cited by 17 · see citing works
Park, J., & Shin, H. (2022) · JMIR Medical Informatics · doi:10.2196/33439 · Cited by 15 · see citing works
The Impact of Contact Force on Signal Quality Indices in Photoplethysmography Measurements
Cause, J. L., Morillo, Á. S., Naranjo, J. C. G., Stiens, J. H., & da Silva, B. (2024) · Applied Sciences · doi:10.3390/app14135704 · Cited by 14 · see citing works
Tun, H. M. (2021) · International Journal of Electrical and Electronic Engineering & Telecommunications · doi:10.18178/ijeetc.10.4.272-282 · Cited by 14 · see citing works
Hong, C., Heo, J., Kang, M.-S., Jang, J., & Yang, H.-J. (2019) · Quantum Information Processing · doi:10.1007/s11128-019-2315-5 · Cited by 14 · see citing works
Hearables: In-Ear Multimodal Data Fusion for Robust Heart Rate Estimation
Żyliński, M., Nassibi, A., Occhipinti, E., Malik, A., Bermond, M., Davies, H. J., & Mandic, D. P. (2024) · BioMedInformatics · doi:10.3390/biomedinformatics4020051 · Cited by 13 · see citing works
van Steijn, N. J., Pepplinkhuizen, S., Postema, P. G., Knops, R. E., & Winter, M. M. (2025) · Heart Rhythm · doi:10.1016/j.hrthm.2025.06.008 · Cited by 12 · see citing works
In-Vivo Estimation of Glucose Level Using PPG Signal
Gupta, S. S., Hossain, S., Haque, C. A., & Kim, K.-D. (2020) · 2020 International Conference on Information and Communication Technology Convergence (ICTC) · doi:10.1109/ictc49870.2020.9289629 · Cited by 12 · see citing works
Prucnal, M. A., Polak, A. G., & Kazienko, P. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.107336 · Cited by 12 · see citing works
Raggi, M., Moore, L. J., & Mesin, L. (2025) · IEEE Access · doi:10.1109/access.2025.3528518 · Cited by 14 · see citing works
Liao, S., Liu, H., Lin, W.-H., Zheng, D., & Chen, F. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1172150 · Cited by 11 · see citing works
Self-citationWang, P., Agarwala, R., Ownby, N. B., Liu, X., & Calhoun, B. H. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3360140 · Cited by 11 · see citing works
Lapitan, D. G., Tarasov, A. P., & Рогаткин, Д. А. (2022) · Journal of Biomedical Photonics & Engineering · doi:10.18287/jbpe22.08.030306 · Cited by 11 · see citing works
Sun, H., Yao, Y., Liu, W., Zhou, S., Du, S., Tan, J., Yin, Y., Xu, L., & Avolio, A. P. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1097879 · Cited by 11 · see citing works
A Multilayer Perceptron-based Carotid-to-Femoral Pulse Wave Velocity Estimation using PPG Signal
Bahloul, M. A., Chahid, A., & Laleg‐Kirati, T. (2021) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi50953.2021.9508617 · Cited by 11 · see citing works
Realistic Pulse Waveforms Estimation via Contrastive Learning in Remote Photoplethysmography
Dong, B., Liu, Y., Yang, K., & Cao, J. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3411135 · Cited by 10 · see citing works
Will Smart Ring be Next Wave of Wearables?
Wang, M., Chen, C., Wu, H., Zhang, J., Zhou, S., & Wang, G. (2024) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas61083.2024.10798374 · Cited by 10 · see citing works
Haghi, M., Danyali, S., Thurow, K., Warnecke, J. M., Wang, J., & Deserno, T. M. (2020) · Applied Sciences · doi:10.3390/app10165470 · Cited by 9 · see citing works
Xie, Z., Wang, G., Cheng, Y., Zhang, Q., Le, M. N., & Wang, R. K. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-20-778 · Cited by 10 · see citing works
Wearable photoplethysmography devices
Charlton, P. H., & Marozas, V. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00011-6 · Cited by 10 · see citing works
Raposo, A., da Silva, H. P., & Sanches, J. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630847 · Cited by 10 · see citing works
Cause, J. L., Morillo, Á. S., da Silva, B., Naranjo, J. C. G., & Stiens, J. H. (2023) · Sensors · doi:10.3390/s23146628 · Cited by 9 · see citing works
Fawcett, T. J., Cooper, C. S., Longenecker, R. J., & Walton, J. P. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108853 · Cited by 9 · see citing works
Heo, J., Hong, C., Kang, M.-S., & Yang, H.-J. (2020) · Scientific Reports · doi:10.1038/s41598-020-71072-0 · Cited by 9 · see citing works
Sarkar, S., & Pahuja, S. K. (2024) · Biomedical Materials & Devices · doi:10.1007/s44174-023-00146-0 · Cited by 7 · see citing works
Noninvasive Non-Contact SpO2 Monitoring Using an Integrated Polarization-Sensing CMOS Imaging Sensor
Sarkar, M., & Assaad, M. M. (2022) · Sensors · doi:10.3390/s22207796 · Cited by 9 · see citing works
Evaluating Vascular Depth-Dependent Changes in Multi-Wavelength PPG Signals Due to Contact Force
Cause, J. L., Morillo, Á. S., da Silva, B., Naranjo, J. C. G., & Stiens, J. H. (2024) · Sensors · doi:10.3390/s24092692 · Cited by 8 · see citing works
Seo, J.-W., Choi, J.-M., Lee, K. H., & Kim, J. U. (2021) · Sensors · doi:10.3390/s21237782 · Cited by 8 · see citing works
Rossi, M., Alessandrelli, G., Dombrovschi, A., Bovio, D., Salito, C., Mainardi, L. T., & Cerveri, P. (2022) · Sensors · doi:10.3390/s22072684 · Cited by 8 · see citing works
Evaluation of PPG Feature Values Toward Biometric Authentication Against Presentation Attacks
Hinatsu, S., Suzuki, D., Ishizuka, H., Ikeda, S., & Oshiro, O. (2022) · IEEE Access · doi:10.1109/access.2022.3167667 · Cited by 8 · see citing works
Tack, B., Vita, D., Mbaki, T. N., Lunguya, O., Toelen, J., & Jacobs, J. A. (2021) · Diagnostics · doi:10.3390/diagnostics11112078 · Cited by 8 · see citing works
Kamei, S., Kanoga, S., Yamamoto, M., Takemura, H., & Tada, M. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3404355 · Cited by 7 · see citing works
Intelligent physiological signal infosecurity: Case study in photoplethysmography (PPG) signal
Lin, C., Wu, J., Pai, N., Chen, P., Li, C., & Pai, C. C. (2021) · IET Signal Processing · doi:10.1049/sil2.12089 · Cited by 7 · see citing works
Pineda-Alpizar, F., Arriola-Valverde, S., Vado-Chacón, M., Sossa, D., Liu, H., & Zheng, D. (2023) · Sensors · doi:10.3390/s23094246 · Cited by 7 · see citing works
Self-citationIntelligent Electrocardiogram Acquisition Via Ubiquitous Photoplethysmography Monitoring
Liu, Z., Zhu, T., Lü, L., Zhang, Y., & Clifton, D. A. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3344187 · Cited by 7 · see citing works
Prada, E. J. A., Ibarra, K. D. M., & Jiménez, K. L. D. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e26036 · Cited by 7 · see citing works
Kazemi, K., Azimi, I., Liljeberg, P., & Rahmani, A. M. (2025) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3712280 · Cited by 6 · see citing works
Development of a Rotation-Robust PPG Sensor for a Smart Ring
Wang, M., Shi, W., Zhang, J., Chen, J., Lin, Q., Chen, C., & Wang, G. (2025) · Sensors · doi:10.3390/s25206326 · Cited by 6 · see citing works
Reliable wrist PPG monitoring by mitigating poor skin sensor contact
Pham, H. M., Ho, M. Y., Zhang, Y., Spathis, D., Saeed, A., & Ma, D. (2025) · Scientific Reports · doi:10.1038/s41598-025-31883-5 · Cited by 10 · see citing works
Wang, S., Ono, R., Wu, D., Aoki, K., Kato, H., Iwahana, T., Okada, S., Kobayashi, Y., & Liu, H. (2024) · BioMedical Engineering OnLine · doi:10.1186/s12938-024-01201-7 · Cited by 6 · see citing works
Self-citationKumar, S., Tayade, A., Shrivastava, A., & Ravi, B. (2025) · Scientific Reports · doi:10.1038/s41598-025-98488-w · Cited by 6 · see citing works
Adasuriya, G., & Haldar, S. (2022) · European Journal of Arrhythmia & Electrophysiology · doi:10.17925/ejae.2022.8.1.7 · Cited by 5 · see citing works
The Challenge of Measuring Exercise: Advancing Metrological Barriers in Wearable Sensing
Corso, J. L., & Peikon, E. (2025) · JMIR mhealth and uhealth · doi:10.2196/79347 · Cited by 5 · see citing works
Smart Ring in Clinical Medicine: A Systematic Review
Gong, E. J., Bang, C. S., Lee, J. J., & Baik, G. H. (2025) · Biomimetics · doi:10.3390/biomimetics10120819 · Cited by 6 · see citing works
Cassani, R., Tiwari, A., & Falk, T. H. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175396 · Cited by 6 · see citing works
Abrisham, K. P., Alipour, K., Tarvirdizadeh, B., & Ghamari, M. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10782553 · Cited by 5 · see citing works
A Programmable Gain Calibration Method to Mitigate Skin Tone Bias in PPG Sensors
MacIsaac, C., Nguyen, M., Uy, A., Kong, T., & Hedayatipour, A. (2025) · Biosensors · doi:10.3390/bios15070423 · Cited by 5 · see citing works
Attack on PPG Biometrics: Presentation Attack by Stealth Recording and Waveform Estimation
Hinatsu, S., Suzuki, D., Ishizuka, H., Ikeda, S., & Oshiro, O. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630803 · Cited by 5 · see citing works
Hypoxia Detection for Confined-Space Workers: Photoplethysmography and Machine-Learning Techniques
Wei, Y., Jin, L., Wang, S., Xu, Y., & Ding, T. (2022) · SN Computer Science · doi:10.1007/s42979-022-01162-5 · Cited by 5 · see citing works
SrPPG: Semi-Supervised Adversarial Learning for Remote Photoplethysmography with Noisy Data
Hasan, Z., Faridee, A. Z. M., Ahmed, M., Ayyanar, S., & Roy, N. (2023) · IEEE International Conference on Smart Computing · doi:10.1109/smartcomp58114.2023.00021 · Cited by 5 · see citing works
Basic Study on Presentation Attacks against Biometric Authentication using Photoplethysmogram
Hinatsu, S., Suzuki, D., Ishizuka, H., Ikeda, S., & Oshiro, O. (2021) · Advanced Biomedical Engineering · doi:10.14326/abe.10.101 · Cited by 5 · see citing works
Photoplethysmographic assessment of arterial stiffness and endothelial function
Zheng, D., Yao, Y., Morrison, I., & Greenwald, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00007-4 · Cited by 6 · see citing works
Self-citation
- Authors
- Hartmann, V., Liu, H., Chen, F., Qiu, Q., Hughes, S., & Zheng, D.
- Affiliations
- Anglia Ruskin University (GB)
- Southern University of Science and Technology (CN)
- Corresponding author
- Chen, Fei
- Zheng, Dingchang
- Venue
- Frontiers in Physiology
- Publisher
- Frontiers Media SA
- Published
- 2019-03-05
- Volume
- 10
- Pages
- 198-198
- ISSN
- 1664-042X (ISSN-L)
- PMC
- PMC6412091
- OpenAlex
- W2919598938
- Cited by
- 173
- References
- 28
- Citations by year
- 2026: 18 · 2025: 31 · 2024: 28 · 2023: 17 · 2022: 35 · 2021: 28 · 2020: 13 · 2019: 3
- FWCI
- 6.95
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Frontiers in Physiology (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Anglia Ruskin Research Online (Anglia Ruskin University) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by-nc-nd)
- Funders
- Newton Fund
- National Natural Science Foundation of China
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmography, reflection index, mean amplitude, finger PPG, deep breathing, cardiovascular function
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review