Estimating heart rate using wrist-type Photoplethysmography and acceleration sensor while running
The DOI matches its Crossref record.
Abstract
This study provides Heart Rate (HR) Estimation using wrist-type Photoplethysmogpraphy (PPG) sensor while the subject is running. We propose the algorithm to estimate heart rate for the wrist-type PPG sensor. Since body motion artifacts easily affect the arm portion, our method in this study also uses accelerometer built in the wrist-type sensor to improve the accuracy of heart rate estimation. Our method has two components. One is rejecting artifacts with the power spectrum's difference between PPG and acceleration obtained by frequency analysis. The other is the reliability of heart rate estimation, defined by the acceleration. Experimental results while our test subjects were running came closer to the holter Electrocardiogram (ECG) in high accuracy (r = 0.98, SD = 8.7 bpm). We, therefore, report the heart rate estimation method which has a higher degree of usability compared to existing methods using ECG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Zhang, Z., Pi, Z., & Liu, B. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2359372 · Cited by 748
Zhang, Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2406332 · Cited by 388
“cancelation [7], [8], spectrum subtraction [9], Kalman filtering [10], wavelet denoising [11], and empirical mode decomposition [12], to name a few.”
MethodAccurate Heart Rate Monitoring During Physical Exercises Using PPG
Temko, A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2676243 · Cited by 293
Sensors and Functionalities of Non-Invasive Wrist-Wearable Devices: A Review
Kamišalić, A., Fister, I., Turkanović, M., & Karakatič, S. (2018) · Sensors · doi:10.3390/s18061714 · Cited by 272
“estimated HR on running persons using the difference between the power spectra of PPG and acceleration [75].”
MethodHeart Rate Estimation From Wrist-Worn Photoplethysmography: A Review
Biswas, D., Simoes-Capela, N., Van Hoof, C., & Van Helleputte, N. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2914166 · Cited by 258
Ye, Y., Cheng, Y., He, W., Hou, M., & Zhang, Z. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2597265 · Cited by 94
Employing Consumer Wearables to Detect Office Workers' Cognitive Load for Interruption Management
Schaule, F., Johanssen, J. O., Bruegge, B., & Loftness, V. (2018) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3191764 · Cited by 77
“The ECG combined with the multiple PPG sensors offers a more accurate measurement of the HRV as well as a measurement of the blood pressure.”
BackgroundInfluentialA Review of Methods for Non-Invasive Heart Rate Measurement on Wrist
De Pinho Ferreira, N., Gehin, C., & Massot, B. (2021) · IRBM · doi:10.1016/j.irbm.2020.04.001 · Cited by 49
Tautan, A.-M., Young, A., Wentink, E., & Wieringa, F. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319795 · Cited by 47
Zong, C., & Jafari, R. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320268 · Cited by 39
I am a "Smart" watch, Smart Enough to Know the Accuracy of My Own Heart Rate Sensor
Ra, H.-K., Ahn, J., Yoon, H. J., Yoon, D., Son, S. H., & Ko, J. (2017) · Proceedings of the 18th International Workshop on Mobile Computing Systems and Applications · doi:10.1145/3032970.3032977 · Cited by 29
Metadata
- Authors
- Fukushima, H., Kawanaka, H., Bhuiyan, M. S., & Oguri, K.
- Venue
- 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2012-08
- Volume
- 2012
- Pages
- 2901-2904
- OpenAlex
- W2078592335
- Cited by
- 126
- References
- 0
- FWCI
- 18.59
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.