CoChat

A frequency domain analysis of respiratory variations in the seismocardiogram signal

Pandia, Keya, Inan, Omer T., Kovacs, Gregory T. A. · 2013 · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Cited by 28

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The seismocardiogram (SCG) signal traditionally measured using a chest-mounted accelerometer contains low-frequency (0-100 Hz) cardiac vibrations that can be used to derive diagnostically relevant information about cardiovascular and cardiopulmonary health. This work is aimed at investigating the effects of respiration on the frequency domain characteristics of SCG signals measured from 18 healthy subjects. Toward this end, the 0-100 Hz SCG signal bandwidth of interest was sub-divided into 5 Hz and 10 Hz frequency bins to compare the spectral energy in corresponding frequency bins of the SCG signal measured during three key conditions of respiration--inspiration, expiration, and apnea. Statistically significant differences were observed between the power in ensemble averaged inspiratory and expiratory SCG beats and between ensemble averaged inspiratory and apneaic beats across the 18 subjects for multiple frequency bins in the 10-40 Hz frequency range. Accordingly, the spectral analysis methods described in this paper could provide complementary and improved classification of respiratory modulations in the SCG signal over and above time-domain SCG analysis methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/embc.2013.6611139

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 5

  1. 10.1016/j.jacc.2011.09.044 · DOI · Paper page
  2. murray, 2013, Disability-adjusted life years (DALYs) for 291 diseases and injuries in 21 regions, 1990-2010: A systematic analysis for the global burden of disease study 2010, The Lancet, 380, 2197, 10.1016/S0140-6736(12)61689-4 · DOI · Paper page
  3. 10.1109/ICASSP.2010.5495553 · DOI
  4. 10.1152/ajpheart.00806.2008 · DOI
  5. holm, 1979, A simple sequentially rejective multiple test procedure, Scand J Stat, 6, 65

Cited by

See all 28

Metadata

Authors
Pandia, K., Inan, O. T., & Kovacs, G. T. A.
Venue
2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Publisher
IEEE
Published
2013-07
Pages
6881-6884
Cited by
28
References
3

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A frequency domain analysis of respiratory variations in the seismocardiogram signal. https://app.cochat.ai/papers/10.1109/embc.2013.6611139
The paper
Pandia, K., Inan, O. T., & Kovacs, G. T. A. (2013). A frequency domain analysis of respiratory variations in the seismocardiogram signal. 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). https://doi.org/10.1109/embc.2013.6611139

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.