Influence of skin type and wavelength on light wave reflectance
Abstract
Purpose A new application of photoplethysmography (PPG) has emerged recently to provide the possibility of heart rate monitoring without a telemetric chest strap. The aim of this study was to determine if a new device could detect pulsation over a broad range of skin types, and what light wavelength would be most suitable for detecting the signals. A light emitting diode-based PPG system was used to detect changes in pulsatile blood flow on 23 apparently healthy individuals (11 male and 12 female, 20-59 years old) of varying skin types classified according to a questionnaire in combination with digital photographs with a skin type chart. Four different light wavelengths (470, 520, 630, and 880 nm) were tested. Normalized modulation level is calculated as the AC/DC component ratio and represents the change in flow over the underlying constant state of flow or perfusion.Results In the resting condition, green light wavelength (520 nm) displayed greater modulation (p < 0.001) than all the other wavelengths analyzed regardless of skin types. Type V (dark brown) skin type was significantly lower in modulation than all other skin types. In the exercise condition, both blue (470 nm) and green (520 nm) light wavelengths displayed greater signal-to-noise ratios than red (630 nm) or infrared (880 nm) light wavelengths (p < 0.001).Conclusions We concluded that a PPG-based device can detect pulsation across all skin types and that a greater resolution was obtained using a green light wavelength at rest and a green or blue light wavelength during exercise.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Melanin absorbs light in the visible spectrum, especially at green wavelengths, reducing signal penetration into the blood-containing dermis and attenuating the AC component of the PPG signal.
“increased melanin reduces signal penetration into the blood-containing dermis, attenuating the AC component of the PPG signal.”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [11]
This pattern is consistent with optical absorption by melanin in the green band and reduced pulsatile content reaching the photodiode.
“consistent with optical absorption by melanin in the green band and reduced pulsatile content reaching the photodiode [10,11,28].”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [11]
Inaccurate PPG heart rate measurements occur up to 15% more frequently in dark skin than in light skin.
“previous research demonstrated that inaccurate PPG HR measurements occur up to 15% more frequently in dark skin as compared to light skin”
From Investigating sources of inaccuracy in wearable optical heart rate sensors (2020) · cites this paper as [25]
Darker skin contains more melanin, which absorbs more green light than lighter skin.
“likely because darker skin contains more melanin which absorbs more green light than lighter skin.”
From Investigating sources of inaccuracy in wearable optical heart rate sensors (2020) · cites this paper as [25]
Optical heart rate measurements primarily measure green light absorption.
“since optical HR measurements primarily measure green light absorption.24,25”
From Investigating sources of inaccuracy in wearable optical heart rate sensors (2020) · cites this paper as [25]
The effect size for the power analysis was based on a pilot study examining differences in light absorption across skin tones and was determined to be 0.3.
“Effect size for the power analysis was based on a pilot study examining differences in light absorption across skin tones25 and was determined to be 0.3.”
From Investigating sources of inaccuracy in wearable optical heart rate sensors (2020) · cites this paper as [25]
Only a small handful of studies examine skin tone and accuracy rates directly.
“there are only a small handful of studies that examine skin tone and accuracy rates directly1–3,11”
From Response To: Investigating sources of inaccuracy in wearable optical heart rate sensors (2021) · cites this paper as [3]
Previously reported studies found that wearables using green light technology had larger error rates in tracking heart rate and energy expenditure for individuals with darker skin tones, especially if exercising.
“This finding is in contrast to previously reported studies finding wearables using green light technology had larger errors rates in tracking heart rate and energy expenditure for individuals with darker skin tones2, especially if exercising3.”
From Response To: Investigating sources of inaccuracy in wearable optical heart rate sensors (2021) · cites this paper as [3]
Due to technological limitations of Photoplethysmography (PPG) green light signaling, health constructs may not be as accurate for a population of people with darker skin tones.
“due to technological limitations of Photoplethysmography (PPG) green light signaling, these health constructs may not be as accurate for a population of people with darker skin tones2,3”
From Response To: Investigating sources of inaccuracy in wearable optical heart rate sensors (2021) · cites this paper as [3]
This effect has been documented by other investigators68 and it may account for some of the errors experienced by dark skin individuals utilizing wearable based on PPG68-71.
“This effect has been documented by other investigators68 and it may account for some of the errors experienced by dark skin individuals utilizing wearable based on PPG68–71.”
From Synthetic photoplethysmography (PPG) of the radial artery through parallelized Monte Carlo and its correlation to body mass index (BMI) (2021) · cites this paper as [68]
Fallow et al. found a better resolution using a green-light wavelength at rest and a green or blue-light wavelength in motion across all skin types.
“Indeed, Fallow et al. found a better resolution using a green-light wavelength at rest and a green or blue-light wavelength in motion across all skin types [80].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [80]
Studies on healthy adults with different skin pigmentation showed that red and green wavelengths could estimate oxygen saturation with good agreement and lower error ratio compared to the traditional pulse oximeter.
“Studies on healthy adults with different skin pigmentation showed that red and green wavelengths could estimate oxygen saturation with good agreement and lower error ratio compared to the traditional pulse oximeter [30,80,102].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [80]
Melanin attenuates the wavelength of incident light and limits penetration to subcutaneous tissue because it is highly light-absorbing.
“Melanin attenuates the wavelength of the incident light and limits the penetration to the subcutaneous tissue because is high light-absorbing [80,101].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [80]
Fallow et al. found that phototype-V (dark brown) skin type has a significant signal-to-noise ratio than all other skin types.
“Fallow et al. classified 23 healthy subjects (11 males and 12 females, 20–59 years old) finding that phototype-V (dark brown) skin type has a significant signal-to-noise ratio than all other skin types [80].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [80]
Fallow et al. identified that green wavelengths (520 nm) displayed greater accuracy in heart rate measurement regardless of skin type when compared to other wavelengths, both at rest and during exercise.
“Fallow et al. identified that green wavelengths (520 nm) displayed greater accuracy in heart rate measurement regardless of skin type when compared to other wavelengths, both at rest and during exercise [20].”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [20]
Green light lacks precision and accuracy, and may not read at all, when measuring heart rate in darker skin types.
“Studies have shown that green light lacks precision and accuracy, and may not read at all, when measuring heart rate in darker skin types [2].”
From Limiting racial disparities and bias for wearable devices in health science research (2020) · cites this paper as [2]
Wearable devices are not as accurate, and may not work at all, in people with darker skin tones.
“We note with deep concern that there is increasing evidence that these devices are not as accurate, and may not work at all, in people with darker skin tones [1, 2].”
From Limiting racial disparities and bias for wearable devices in health science research (2020) · cites this paper as [2]
Fallow et al. found that mean modulation (perfusion index, AC/DC) was significantly lower in Fitzpatrick V individuals than others for all wavelengths (p < 0.001).
“Mean modulation, often termed the perfusion index, defined as the ratio of AC/DC, was significantly lower in Fitzpatrick V individuals than others for all wavelengths (p < 0.001).”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [52]
In the resting condition, green light had larger mean modulation (p < 0.001) than other wavelengths, and after exercise, blue and green had greater SNR ratios than red or infrared (p < 0.001).
“In the resting condition, green light had larger mean modulation (p < 0.001) than other wavelengths, and after exercise, blue and green had greater SNR ratios than red or infrared (p < 0.001).”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [52]
Cites
(2014) · Medical Entomology and Zoology · Cited by 9,400 · see citing works
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Age-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775 · cited 1× · see citing works
“Indeed heart rate has been a useful and widely used index of physical exertion and intensities of effort during physical activity [10].”
BackgroundSelf-citationAnderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456 · see citing works
Physical Activity, Fitness, and Health
(2012) · doi:10.5040/9781718209107.part-001 · Cited by 742 · see citing works
Physical Activity, Fitness, and Health
Bouchard, C., Shephard, R. J., & Brubaker, P. H. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199401000-00024 · Cited by 657 · see citing works
Zonios, G., Bykowski, J., & Kollias, N. (2001) · Journal of Investigative Dermatology · doi:10.1046/j.0022-202x.2001.01577.x · Cited by 477 · see citing works
Skin photoplethysmography — a review
Kamal, A. A. R., Harness, J. B., Irving, G., & Mearns, A. J. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90159-4 · Cited by 328 · see citing works
Exercise Prescription for the Elderly
Mazzeo, R., & Tanaka, H. (2001) · Sports Medicine · doi:10.2165/00007256-200131110-00003 · Cited by 217 · see citing works
Self-citationIshikawa-Takata, K. (2003) · American Journal of Hypertension · doi:10.1016/s0895-7061(03)00895-1 · Cited by 190 · see citing works
In vivo reflectance of blood and tissue as a function of light wavelength
Cui, W., Ostrander, L. E., & Lee, B. Y. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55667 · Cited by 149 · see citing works
Reflection photoplethysmography of arterial-blood-volume pulses
Weinman, J., Hayat, A., & Raviv, G. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441571 · Cited by 57 · see citing works
Dose–response issues from a biological perspective.
Haskell, W. L. (1994) · Cited by 45 · see citing works
Post‐exercise palpation of pulse rates: its applicability to habitual exercisers
DeVan, A. E., Lacy, B. K., Cortez‐Cooper, M. Y., & Tanaka, H. (2005) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/j.1600-0838.2004.409.x · Cited by 11 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Investigating sources of inaccuracy in wearable optical heart rate sensors
Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0226-6 · Cited by 673 · see citing works
“Difference in green light mean absorption for different skin tones during activity was used to calculate effect size since optical HR measurements primarily measure green light absorption.(24,25) Based on the ANOVA power calculation, we required eight participants per skin tone category (6 skin tone categories on FP s…”
MethodPhotoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 450 · see citing works
Deep PPG: Large-Scale Heart Rate Estimation with Convolutional Neural Networks
Reiss, A., Indlekofer, I., Schmidt, P., & Laerhoven, K. V. (2019) · Sensors · doi:10.3390/s19143079 · Cited by 383 · see citing works
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Accuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336 · see citing works
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250 · see citing works
A Review of Wearable Multi-Wavelength Photoplethysmography
Ray, D., Collins, T., Woolley, S., & Ponnapalli, P. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3121476 · Cited by 155 · see citing works
Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking.
(2016) · PubMed Central · Cited by 150 · see citing works
Validation of photoplethysmography as a method to detect heart rate during rest and exercise
Spierer, D. K., Rosen, Z., Litman, L. L., & Fujii, K. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1047536 · Cited by 139 · see citing works
Limiting racial disparities and bias for wearable devices in health science research
Colvonen, P. J., DeYoung, P. N., Bosompra, N.-O. A., & Owens, R. L. (2020) · Sleep · doi:10.1093/sleep/zsaa159 · Cited by 137 · see citing works
Smart Wearables for Cardiac Monitoring—Real-World Use beyond Atrial Fibrillation
Duncker, D., Ding, W. Y., Etheridge, S. P., Noseworthy, P. A., Veltmann, C., Yao, X., Bunch, T. J., & Gupta, D. (2021) · Sensors · doi:10.3390/s21072539 · Cited by 132 · see citing works
Cabanas, A. M., Fuentes-Guajardo, M., Latorre, K., León, D., & Martín-Escudero, P. (2022) · Sensors · doi:10.3390/s22093402 · Cited by 124 · see citing works
Cosoli, G., Spinsante, S., & Scalise, L. (2020) · Measurement · doi:10.1016/j.measurement.2020.107789 · Cited by 122 · see citing works
Wearable Photoplethysmography for Cardiovascular Monitoring.
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · KTUePubl (Repository of Kaunas University of Technology) · doi:10.17863/cam.81148 · Cited by 113 · see citing works
From lab to life: how wearable devices can improve health equity
Walter, J. R., Xu, S., & Rogers, J. A. (2024) · Nature Communications · doi:10.1038/s41467-023-44634-9 · Cited by 108 · see citing works
Continuous cuffless blood pressure monitoring with a wearable ring bioimpedance device
Sel, K., Osman, D., Huerta, N., Edgar, A., Pettigrew, R. I., & Jafari, R. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00796-w · Cited by 100 · see citing works
Stone, J. D., Ulman, H. K., Tran, K., Thompson, A. G., Halter, M. D., Ramadan, J. H., Stephenson, M., Finomore, V. S., Galster, S. M., Rezai, A. R., et al. (2021) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2021.585870 · Cited by 95 · see citing works
Koerber, D., Khan, S., Shamsheri, T., Kirubarajan, A., & Mehta, S. (2023) · Journal of Racial and Ethnic Health Disparities · doi:10.1007/s40615-022-01446-9 · Cited by 91 · see citing works
Origin of Photoplethysmographic Waveform at Green Light
Kamshilin, A. A., & Борисович, М. Н. (2017) · Physics Procedia · doi:10.1016/j.phpro.2017.01.024 · Cited by 90 · see citing works
Ajmal, Boonya-Ananta, T., Rodriguez, A. J., Du Le, V. N., & Ramella-Roman, J. C. (2021) · Biomedical Optics Express · doi:10.1364/boe.439893 · Cited by 79 · see citing works
Smartphone Apps Using Photoplethysmography for Heart Rate Monitoring: Meta-Analysis
Ridder, B. D., Rompaey, B. V., Kampen, J. K., Haine, S. E. F., & Dilles, T. (2018) · JMIR Cardio · doi:10.2196/cardio.8802 · Cited by 73 · see citing works
Scardulla, F., D’Acquisto, L., Colombarini, R., Hu, S., Pasta, S., & Bellavia, D. (2020) · Sensors · doi:10.3390/s20185052 · Cited by 72 · see citing works
Validating cuffless continuous blood pressure monitoring devices
Hu, J., Martin, G., Iyengar, S., Kovell, L. C., Plante, T. B., van Helmond, N., Dart, R. A., Brady, T. M., Turkson‐Ocran, R., & Juraschek, S. P. (2023) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2023.01.001 · Cited by 74 · see citing works
Boonya-ananta, T., Rodriguez, A. J., Ajmal, A., Du Le, V. N., Hansen, A. K., Hutcheson, J. D., & Ramella-Roman, J. C. (2021) · Scientific Reports · doi:10.1038/s41598-021-82124-4 · Cited by 70 · see citing works
Pulse Wave Velocity: Methodology, Clinical Applications, and Interplay with Heart Rate Variability
Pilz, N., Heinz, V., Ax, T., Fesseler, L., Patzak, A., & Bothe, T. (2024) · Reviews in cardiovascular medicine · doi:10.31083/j.rcm2507266 · Cited by 70 · see citing works
Ethical Considerations of Wearable Technologies in Human Research
Tu, J., & Gao, W. F. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100127 · Cited by 71 · see citing works
Nowara, E. M., McDuff, D., & Veeraraghavan, A. (2020) · 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw50498.2020.00150 · Cited by 66 · see citing works
Response To: Investigating sources of inaccuracy in wearable optical heart rate sensors
Colvonen, P. J. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00408-5 · Cited by 65 · see citing works
Daniore, P., Nittas, V., Haag, C., Bernard, J., Gonzenbach, R. R., & von Wyl, V. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01151-3 · Cited by 63 · see citing works
The accuracy of heartbeat detection using photoplethysmography technology in cardiac patients
Blok, S., Piek, M. A., Tulevski, I. I., Somsen, G. A., & Winter, M. M. (2021) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2021.06.009 · Cited by 59 · see citing works
Jegan, R., & Nimi, W. S. (2023) · Journal of Public Health · doi:10.1007/s10389-023-01893-6 · Cited by 57 · see citing works
Cuffless Blood Pressure in clinical practice: challenges, opportunities and current limits.
Henry, B., Merz, M., Hoang, H., Abdulkarim, G., Wosik, J., & Schoettker, P. (2024) · Blood Pressure · doi:10.1080/08037051.2024.2304190 · Cited by 54 · see citing works
Li, J., Chu, H., Chen, Z., Yiu, C. K., Qu, Q., Li, Z.-Y., & Yu, X. (2024) · ACS Nano · doi:10.1021/acsnano.4c04291 · Cited by 50 · see citing works
Støve, M. P., Haucke, E., Nymann, M. L., Sigurdsson, T., & Larsen, B. T. (2018) · Journal of Sports Sciences · doi:10.1080/02640414.2018.1535563 · Cited by 51 · see citing works
Navalta, J. W., Ramirez, G. G., Maxwell, C., Radzak, K. N., & McGinnis, G. R. (2020) · Scientific Reports · doi:10.1038/s41598-020-64185-z · Cited by 49 · see citing works
Hernandez, M. F., & Rodríguez, F. (2022) · Current Cardiovascular Risk Reports · doi:10.1007/s12170-022-00711-0 · Cited by 49 · see citing works
Validity of heart rate measurements by the Garmin Forerunner 225 at different walking intensities
Claes, J., Buys, R., Ávila, A., Finlay, D., Kennedy, A., Guldenring, D., Budts, W., & Cornelissen, V. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2017.1333166 · Cited by 49 · see citing works
Sañudo, B., De Hoyo, M., Muñoz-López, A., Perry, J., & Abt, G. (2019) · Journal of Medical Systems · doi:10.1007/s10916-019-1325-2 · Cited by 48 · see citing works
Peralta, E., Lázaro, J. M., Bailón, R., Marozas, V., & Gil, E. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab009b · Cited by 48 · see citing works
The Clinical Value of Heart Rate Monitoring Using an Apple Watch
Karmen, C. L., Reisfeld, M., McIntyre, M. K., Timmermans, R. J., & Frishman, W. H. (2019) · Cardiology in Review · doi:10.1097/crd.0000000000000243 · Cited by 47 · see citing works
Motion-Tolerant Non-Contact Heart-Rate Measurements from Radar Sensor Fusion
Rong, Y., Dutta, A., Chiriyath, A. R., & Bliss, D. W. (2021) · Sensors · doi:10.3390/s21051774 · Cited by 45 · see citing works
Stuyck, H., Costa, L. D., Axel Cleeremans, B., & den Bussche, E. V. (2022) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2022.10.003 · Cited by 44 · see citing works
Pham, C., Poorzargar, K., Nagappa, M., Saripella, A., Parotto, M., Englesakis, M. F., Lee, K., & Chung, F. F. (2021) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-021-00734-9 · Cited by 43 · see citing works
Peláez‐Coca, M. D., Hernando, A., Lázaro, J. M., & Gil, E. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3099208 · Cited by 41 · see citing works
Yan, L., Hu, S., Alzahrani, A., Alharbi, S., & Blanos, P. (2017) · Biosensors · doi:10.3390/bios7020022 · Cited by 40 · see citing works
Prospective validation of smartphone-based heart rate and respiratory rate measurement algorithms
Bae, S., Borac, S., Emre, Y., Wang, J., Wu, J., Kashyap, M., Kang, S., Chen, L., Moran, M., Cannon, J., et al. (2022) · Communications Medicine · doi:10.1038/s43856-022-00102-x · Cited by 41 · see citing works
Determinants of photoplethysmography signal quality at the wrist
Charlton, P. H., Marozas, V., Mejía‐Mejía, E., Kyriacou, P. A., & Mant, J. (2025) · PLOS Digital Health · doi:10.1371/journal.pdig.0000585 · Cited by 38 · see citing works
Continuous Non-Invasive Blood Pressure Measurement Using 60 GHz-Radar—A Feasibility Study
Vysotskaya, N., Will, C., Servadei, L., Maul, N., Mandl, C., Nau, M. A., Harnisch, J., & Maier, A. (2023) · Sensors · doi:10.3390/s23084111 · Cited by 37 · see citing works
Wearables for health and fitness: Measurement characteristics and accuracy
Scalise, L., & Cosoli, G. (2018) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2018.8409635 · Cited by 34 · see citing works
At the Crossroads! Time to Start Taking Smartwatches Seriously
Lima, F. V., Kadiyala, V., Huang, A., Agusala, K., Cho, D. J., Freeman, A. M., & Druz, R. S. (2022) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2022.06.020 · Cited by 34 · see citing works
Challenges and Opportunities for Applying Wearable Technology to Sleep
Tobin, S. Y., Williams, P., Baron, K. G., Halliday, T. M., & Depner, C. M. (2021) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2021.07.002 · Cited by 32 · see citing works
Berwal, D., Kuruba, A., Shaikh, A. M., Udupa, A., & Baghini, M. S. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3170069 · Cited by 32 · see citing works
Любашина, О. А., Mamontov, O. V., Volynsky, M. A., Zaytsev, V. V., & Kamshilin, A. A. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01235 · Cited by 31 · see citing works
Biomedical Silicones: Leveraging Additive Strategies to Propel Modern Utility
Marmo, A. C., & Grunlan, M. A. (2023) · ACS Macro Letters · doi:10.1021/acsmacrolett.2c00701 · Cited by 32 · see citing works
Promoting racial equity in digital health: applying a cross-disciplinary equity framework
Raza, M. M., Venkatesh, K. P., & Kvedar, J. C. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00747-5 · Cited by 30 · see citing works
History and evolution of blood pressure measurement
Noh, S. A., Kim, H.-S., Kang, S., Yoon, C., Youn, T., & Chae, I. (2024) · Clinical Hypertension · doi:10.1186/s40885-024-00268-7 · Cited by 34 · see citing works
PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring—A Comprehensive Review
Lapsa, D., Janeliukštis, R., Metshein, M., & Selavo, L. (2024) · Applied Sciences · doi:10.3390/app14177451 · Cited by 30 · see citing works
Influence of a skin status on the light interaction with dermis
Kamshilin, A. A., Mamontov, O. V., Koval, V. T., Zayats, G. A., & Владимирович, Р. Р. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.004326 · Cited by 25 · see citing works
The validation of smartphone applications for heart rate measurement
Pipitprapat, W., Harnchoowong, S., Suchonwanit, P., & Sriphrapradang, C. (2018) · Annals of Medicine · doi:10.1080/07853890.2018.1531144 · Cited by 24 · see citing works
Wearable Devices for Remote Monitoring of Chronic Diseases: Systematic Review
Tegegne, M. D., Kalhori, S. R. N., Haas, P., Sobotta, V. M. G., Warnecke, J. M., & Deserno, T. M. (2025) · JMIR mhealth and uhealth · doi:10.2196/74071 · Cited by 31 · see citing works
Skin tone, confidence, and data quality of heart rate sensing in WearOS smartwatches
Ray, I., Liaqat, D., Gabel, M., & de Lara, E. (2021) · 2021 IEEE International Conference on Pervasive Computing and Communications Workshops and other Affiliated Events (PerCom Workshops) · doi:10.1109/percomworkshops51409.2021.9431120 · Cited by 23 · see citing works
Mahloko, L., & Adebesin, F. (2020) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-45002-1_9 · Cited by 23 · see citing works
Oxygen Saturation Behavior by Pulse Oximetry in Female Athletes: Breaking Myths
Martín-Escudero, P., Cabanas, A. M., Fuentes, M. E., & Galindo-Canales, M. (2021) · Biosensors · doi:10.3390/bios11100391 · Cited by 25 · see citing works
Non-Contact Reflectance Photoplethysmography: Progress, Limitations, and Myths
Špetlík, R., Čech, J., & Matas, J. (2018) · International Conference on Automatic Face and Gesture Recognition · doi:10.1109/fg.2018.00111 · Cited by 22 · see citing works
Contactless Monitoring of Microcirculation Reaction on Local Temperature Changes
Volynsky, M. A., Борисович, М. Н., Mamontov, O. V., & Kamshilin, A. A. (2019) · Applied Sciences · doi:10.3390/app9224947 · Cited by 20 · see citing works
Establishing best practices in photoplethysmography signal acquisition and processing
Charlton, P. H., Pilt, K., & Kyriacou, P. A. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac6cc4 · Cited by 23 · see citing works
Puranen, A., Halkola, T., Kirkeby, O., & Vehkaoja, A. T. (2020) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors47125.2020.9278523 · Cited by 19 · see citing works
Shahmohammadi, M., Guan, B., de Godoy, R. V., Dwivedi, A., Nielsen, P. M. F., & Liarokapis, M. V. (2023) · Scientific Reports · doi:10.1038/s41598-022-25982-w · Cited by 19 · see citing works
Carek, A. M., & Inan, O. T. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2683801 · Cited by 20 · see citing works
Validity of the Polar Vantage M watch when measuring heart rate at different exercise intensities
Shumate, T., Link, M., Furness, J. W., Kemp‐Smith, K., Simas, V., & Climstein, M. (2021) · PeerJ · doi:10.7717/peerj.10893 · Cited by 18 · see citing works
Reply: Matters Arising ‘Investigating sources of inaccuracy in wearable optical heart rate sensors’
Bent, B., Enache, O. M., Goldstein, B., Kibbe, W., & Dunn, J. P. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00409-4 · Cited by 17 · see citing works
Angelucci, A., Li, Z., Stoimenova, N., & Canali, S. (2022) · AI & Society · doi:10.1007/s00146-022-01562-4 · Cited by 17 · see citing works
Privacy threats of behaviour identity detection in VR
Kumarapeli, D., Jung, S., & Lindeman, R. W. (2024) · Frontiers in Virtual Reality · doi:10.3389/frvir.2024.1197547 · Cited by 17 · see citing works
Pont, M. P. D., & Marques, J. L. B. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2963508 · Cited by 17 · see citing works
Mastoris, I., DeFilippis, E. M., Martyn, T., Morris, A. A., Spall, H. G. C. V., & Sauer, A. J. (2023) · Cardiac failure review · doi:10.15420/cfr.2022.22 · Cited by 16 · see citing works
Human vital sign determination using tactile sensing and fuzzy triage system
Kerr, E., McGinnity, T. M., Coleman, S., & Shepherd, A. (2021) · Expert Systems with Applications · doi:10.1016/j.eswa.2021.114781 · Cited by 18 · see citing works
Mather, J. D., Hayes, L. D., Mair, J. L., & Sculthorpe, N. F. (2024) · Frontiers in Digital Health · doi:10.3389/fdgth.2024.1326511 · Cited by 17 · see citing works
Contactless monitoring of the blood-flow changes in upper limbs
Zaytsev, V. V., Miridonov, S. V., Mamontov, O. V., & Kamshilin, A. A. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.005387 · Cited by 14 · see citing works
Guo, C.-Y., Huang, W., Chang, H., & Hsieh, T.-L. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3288151 · Cited by 13 · see citing works
Assessment of facial video-based detection of atrial fibrillation across human complexion
Couderc, J., Page, A., Lutz, M., Tsouri, G. R., & HALL, B. W. (2022) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2022.08.003 · Cited by 13 · see citing works
Watanabe, K., Izumi, S., Sasai, K., Yano, Y., Kawaguchi, H., & Yoshimoto, M. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2956948 · Cited by 13 · see citing works
Feasibility of Using an Armband Optical Heart Rate Sensor in Naturalistic Environment
Yu, H., Kotlyar, M., Dufresne, S. R., THURAS, P. D., & Pakhomov, S. (2022) · Pacific Symposium on Biocomputing (PSB) · doi:10.1142/9789811270611_0005 · Cited by 12 · see citing works
Ceugniez, M., Devanne, H., & Hermand, É. (2024) · JMIR mhealth and uhealth · doi:10.2196/54871 · Cited by 11 · see citing works
Støve, M. P., Holm, R. S., Kjaersgaard, A. S., Duncker, K., Jensen, M. R., & Larsen, B. T. (2020) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2020.1753836 · Cited by 12 · see citing works
Do Affective Cues Validate Behavioural Metrics for Search?
McDuff, D., Thomas, P., Craswell, N., Rowan, K., & Czerwinski, M. P. (2021) · International ACM SIGIR Conference on Research and Development in Information Retrieval (SIGIR) · doi:10.1145/3404835.3462894 · Cited by 12 · see citing works
Non-invasive measurement of pulse waves in the soles of rats using an RGB camera
Takahashi, M., Yamaguchi, T., Takahashi, R., Ogawa‐Ochiai, K., Tsumura, N., & Iijima, N. (2021) · OSA Continuum · doi:10.1364/osac.433228 · Cited by 11 · see citing works
Mulholland, A. M., MacDonald, H. V., Aguiar, E. J., & Wingo, J. E. (2025) · European Journal of Applied Physiology · doi:10.1007/s00421-025-05977-x · Cited by 10 · see citing works
Zhang, H., Zhu, L., Nathan, V., Kuang, J., Kim, J., Gao, J. A., & Olgin, J. E. (2021) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3463503 · Cited by 10 · see citing works
Kamshilin, A. A., Zaytsev, V. V., Belaventseva, A. V., Podolyan, N. P., Volynsky, M. A., Sakovskaia, A. V., Владимирович, Р. Р., & Mamontov, O. V. (2022) · Sensors · doi:10.3390/s22155727 · Cited by 10 · see citing works
Burton, T., Saiko, G., Cao, M., & Douplik, A. (2022) · Journal of Biophotonics · doi:10.1002/jbio.202200187 · Cited by 10 · see citing works
Cruz, S., Lu, C., Ulloa, M., Redding, A., Hester, J. D., & Jacobs, M. L. (2024) · JMIR mhealth and uhealth · doi:10.2196/50826 · Cited by 11 · see citing works
Abe, M., Yoshizawa, M., Obara, K., Sugita, N., Homma, N., & Yambe, T. (2015) · Advanced Biomedical Engineering · doi:10.14326/abe.4.1 · Cited by 10 · see citing works
Wearable photoplethysmography devices
Charlton, P. H., & Marozas, V. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00011-6 · Cited by 10 · see citing works
Bonetta-Misteli, F., Collins, T., Pavek, T., Carlgren, M. P., Bashe, D., Frolova, A. I., Shmuylovich, L., & O’Brien, C. M. (2023) · Biomedical Optics Express · doi:10.1364/boe.494720 · Cited by 9 · see citing works
Pasta, S., Blanos, P., Yan, L., Hu, S., Scardulla, F., D’Acquisto, L., & Barrett, L. A. (2018) · Design and Quality for Biomedical Technologies · doi:10.1117/12.2287845 · Cited by 9 · see citing works
Leveraging Attention-reinforced UWB Signals to Monitor Respiration during Sleep
Li, S., Jin, B., Wang, Z., Zhang, F., Ren, X., & Liu, H. (2024) · ACM Transactions on Sensor Networks · doi:10.1145/3680550 · Cited by 8 · see citing works
Multi-wavelength SPAD photoplethysmography for cardio-respiratory monitoring
Cusini, I., Rinaldi, R., Castiglioni, P., Faini, A., & Villa, F. (2023) · Frontiers in Physics · doi:10.3389/fphy.2023.952103 · Cited by 8 · see citing works
Enhanced SpO2 estimation using explainable machine learning and neck photoplethysmography
Zhong, Y., Jatav, A., Afrin, K., Shivaram, T., & Bukkapatnam, S. (2023) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2023.102685 · Cited by 8 · see citing works
Applications of camera-based physiological measurement beyond healthcare
McDuff, D. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822281-2.00016-0 · Cited by 8 · see citing works
Physiological origin of camera-based PPG imaging
Kamshilin, A. A., & Mamontov, O. V. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822281-2.00010-x · Cited by 8 · see citing works
- Authors
- Fallow, B. A., Tarumi, T., & Tanaka, H.
- Affiliations
- The University of Texas at Austin (US)
- Corresponding author
- Tanaka, Hirofumi
- Venue
- Journal of Clinical Monitoring and Computing
- Published
- 2013-02-09
- Volume
- 27
- Issue
- 3
- Pages
- 313-317
- ISSN
- 1387-1307 (ISSN-L)
- 1573-2614
- OpenAlex
- W2066932506
- Cited by
- 162
- References
- 14
- Citations by year
- 2026: 12 · 2025: 13 · 2024: 23 · 2023: 22 · 2022: 19 · 2021: 27 · 2020: 12 · 2019: 11 · 2018: 8 · 2017: 8 · 2016: 3 · 2015: 4
- FWCI
- 1.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Clinical Monitoring and Computing (publishedVersion)
- PubMed (publishedVersion)
- Texas ScholarWorks (Texas Digital Library) (submittedVersion)
- Funders
- Omron Healthcare
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- photoplethysmography, skin type, light wavelength, heart rate monitoring, pulsatile blood flow, signal-to-noise ratio, physical activity, green light, blue light, infrared radiation, skin pigmentation
- MeSH terms
- Adult, Female, Heart Rate, Humans, Light, Male, Middle Aged, Monitoring, Physiologic, Skin, Skin Pigmentation, Exercise, Photoplethysmography, Optical Phenomena, Young Adult, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review