Disturbance free operation of a multiphase current regulated motor drive with an opened phase
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
An improved induction motor control strategy is proposed incorporating a multiphase machine which allows for continuous, disturbance free operation of the drive even with complete loss of one (or more) legs of the inverter or motor phase. A complete analysis of both even phase and odd phase machines utilizing this control and circuit concept is presented. By using a five-phase or a seven-phase machine, it is possible to take advantage of the additional degrees of freedom as a result of more phases. It is shown that when one phase is open circuited, with appropriate control, the zero sequence current is no longer a necessary component as in a three-phase machine. That is, one can eliminate the need for a neutral line and the machine can still be controlled so as to produce a smooth nonpulsating torque. It has also been determined that the ratings of motor and inverter will both benefit by the use of extra phases.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A strategy for improving reliability of field-oriented controlled induction motor drives
Liu, T.-H., Fu, J.-R., & Lipo, T. A. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.245714 · Cited by 374
Self-citationImproved Reliability in Solid-State AC Drives by Means of Multiple Independent Phase Drive Units
Jahns, T. M. (1980) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1980.4503793 · Cited by 358
A strategy for improving reliability of field oriented controlled induction motor drives
Liu, T.-H., Fu, J.-R., & Lipo, T. A. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1991.178194 · Cited by 45
Self-citation
Cited by
Multiphase Electric Machines for Variable-Speed Applications
Levi, E. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918488 · Cited by 2,157
Multiphase induction motor drives – a technology status review
Levi, E., Bojoi, R., Profumo, F., Toliyat, H. A., & Williamson, S. (2007) · IET Electric Power Applications · doi:10.1049/iet-epa:20060342 · Cited by 1,619
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724
Self-citationSurvey on Fault-Tolerant Techniques for Power Electronic Converters
Zhang, W., Xu, D., Enjeti, P. N., Li, H., Hawke, J. T., & Krishnamoorthy, H. S. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2304561 · Cited by 587
Che, H. S., Duran, M. J., Levi, E., Jones, M., Hew, W.-P., & Rahim, N. A. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293195 · Cited by 394
Experimental fault-tolerant control of a PMSM drive
Bolognani, S., Zordan, M., & Zigliotto, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873223 · Cited by 382
Fault-Tolerant Interior-Permanent-Magnet Machines for Hybrid Electric Vehicle Applications
Parsa, L., & Toliyat, H. A. (2007) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2007.896978 · Cited by 317
A Review on Multiphase Drives for Automotive Traction Applications
Salem, A., & Narimani, M. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2956355 · Cited by 311
Torque density improvement in a six-phase induction motor with third harmonic current injection
Lyra, R. O. C., & Lipo, T. A. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.802938 · Cited by 310
Self-citationFault-Tolerant Control of Five-Phase Permanent-Magnet Motors With Trapezoidal Back EMF
Dwari, S., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2045322 · Cited by 289
Levi, E., Jones, M., Vukosavic, S. N., & Toliyat, H. A. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.823241 · Cited by 274
Kianinezhad, R., Nahid-Mobarakeh, B., Baghli, L., Betin, F., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918479 · Cited by 266
Guzman, H., Duran, M. J., Barrero, F., Bogado, B., & Toral, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2289882 · Cited by 258
An Optimal Control Technique for Multiphase PM Machines Under Open-Circuit Faults
Dwari, S., & Parsa, L. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.920643 · Cited by 244
“The open circuit fault-tolerant operations of the multiphase PM machines and the multiphase induction machines, both with only sinusoidal stator winding distributions, are discussed in [19] and [ 20 ], respectively.”
MethodGuzman, H., Duran, M. J., Barrero, F., Zarri, L., Bogado, B., Gonzalez Prieto, I., & Arahal, M. R. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2418732 · Cited by 231
“forms of the reference currents in the α-β subspace (given for the maximum current allowed for ML) are [5]”
BackgroundInfluentialMohammadpour, A., Sadeghi, S., & Parsa, L. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2247011 · Cited by 210
Open-Phase Fault-Tolerant Direct Torque Control Technique for Five-Phase Induction Motor Drives
Bermudez, M., Gonzalez-Prieto, I., Barrero, F., Guzman, H., Duran, M. J., & Kestelyn, X. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2610941 · Cited by 208
“, reduce copper losses or ensure maximum torque capability [16]–[18]) can be applied.”
BackgroundRyu, H.-M., Kim, J.-W., & Sul, S.-K. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.876074 · Cited by 187
“From (2) and (3), the equivalent transformation matrix from the v-, w-, x-, and y-phase variables to the synchronously rotating d1−q1−q3−n-axis variables is given like (4), shown at the bottom of the next page.”
BackgroundShamsi-Nejad, M.-A., Nahid-Mobarakeh, B., Pierfederici, S., & Meibody-Tabar, F. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918485 · Cited by 160
Baudart, F., Dehez, B., Matagne, E., Telteu-Nedelcu, D., Alexandre, P., & Labrique, F. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2170393 · Cited by 98
“, with one or more phases in open circuit) is then performed by forcing the currents to remain sinusoidal and, in most of the cases, to have all the same amplitude [21], [35].”
BackgroundResultInfluentialAnalysis and Experimental Verification of a Fault-Tolerant HEV Powertrain
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2245513 · Cited by 81
“But such a configuration is only suitable for motors with a particular design structure, which will exclude its applicability to general motor drive systems [30].”
Background
Metadata
- Authors
- Fu, J.-R., & Lipo, T. A.
- Venue
- Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting
- Publisher
- IEEE
- Published
- 2002-12-30
- Pages
- 637-644
- ISSN
- 0197-2618 (ISSN-L)
- OpenAlex
- W2146384643
- Cited by
- 318
- References
- 3
- FWCI
- 9.26
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.