A soft exosuit for patients with stroke: Feasibility study with a mobile off-board actuation unit
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
In this paper, we present the first application of a soft exosuit to assist walking after stroke. The exosuit combines textile garments with cable driven actuators and is lighter and more compliant as compared to traditional rigid exoskeletons. By avoiding the use of rigid elements, exosuits offer greater comfort, facilitate donning/doffing, and do not impose kinematic restrictions on the wearer - all while retaining the ability to generate significant moments at target joints during walking. The stroke-specific exosuit adapted from previous exosuit designs provides unilateral assistance to the paretic limb during walking. This paper describes stroke-specific design considerations, the design of the textile components, the development of a research-focused, mobile off-board actuation unit capable of testing the exosuit in a variety of walking conditions, a real-time gait detection and control algorithm, and proof-of-principle data validating the use of the exosuit in the chronic stroke population. Ultimately, we demonstrate reliable tracking of poststroke gait, appropriate timing of assistive forces, and improvements in key gait metrics. These preliminary results demonstrate the feasibility and promise of exosuits for poststroke gait assistance and training. Future work will involve the creation of a portable, body-worn system based on the specifications obtained from such feasibility studies that will enable community-based rehabilitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2015 Update: A Report From the American Heart Association
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., de Ferranti, S., Després, J.-P., Fullerton, H. J., Howard, V. J., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000152 · Cited by 5,797
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047 · cited 1×
“Control algorithms for walking assistance often rely on gait event data such as toe off (TO) and heel strike (HS) to generate assistance profiles [26].”
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958 · cited 1×
“Some of these systems [14] have recently received FDA approval and have been commercialized for personal Figure 2.”
BackgroundRobot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Robotic Orthosis Lokomat: a rehabilitation and research tool
Jezernik, S., Colombo, G., Keller, T., Frueh, H., & Morari, M. (2003) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2003.03017.x · Cited by 503 · cited 1×
“Clinic-based systems, which are often treadmill-bound [9], [11]–[13] aim to complement traditional labor-intensive gait rehabilitation.”
BackgroundDesign and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation
Park, Y.-L., Chen, B.-R., Pérez-Arancibia, N. O., Young, D., Stirling, L., Wood, R. J., Goldfield, E. C., & Nagpal, R. (2014) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/1/016007 · Cited by 497
A biologically inspired soft exosuit for walking assistance
Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914562476 · Cited by 450 · cited 3×
“The PF suit module was adapted from previous multi-articular exosuits described in [18]–[20].”
BackgroundMethodInfluentialSelf-citationBowden, M. G., Balasubramanian, C. K., Neptune, R. R., & Kautz, S. A. (2006) · Stroke · doi:10.1161/01.str.0000204063.75779.8d · Cited by 388 · cited 1×
“Propulsive impulse was calculated as the integral of positive anterior-posterior GRF (AP GRF) during stance [31], and paretic propulsion was defined as the proportion of the total propulsive impulse produced by paretic side [32].”
MethodA lightweight soft exosuit for gait assistance
Wehner, M., Quinlivan, B., Aubin, P. M., Martinez-Villalpando, E., Baumann, M., Stirling, L., Holt, K., Wood, R., & Walsh, C. (2013) · 2013 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2013.6631046 · Cited by 361 · cited 1×
“The stroke-specific exosuit we present in this paper deviates from our previous designs [17]–[24] by providing only unilateral assistance to the paretic ankle during push off, and additionally provides dorsiflexion assistance during the swing phase via a new textile module.”
MethodSelf-citation
Cited by
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
Self-citationTextile Technology for Soft Robotic and Autonomous Garments
Sanchez, V., Walsh, C. J., & Wood, R. J. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008278 · Cited by 292
Self-citationA biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking
Panizzolo, F. A., Galiana, I., Asbeck, A. T., Siviy, C., Schmidt, K., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0150-9 · Cited by 291
Self-citationOpportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Self-citationGrimmer, M., Riener, R., Walsh, C. J., & Seyfarth, A. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0458-8 · Cited by 249
Self-citation
Metadata
- Authors
- Bae, J., Maria De Rossi, S. M., O'Donnell, K., Hendron, K. L., Awad, L. N., Teles Dos Santos, T. R., De Araujo, V. L., Ding, Y., Holt, K. G., Ellis, T. D., & Walsh, C. J.
- Venue
- 2015 IEEE International Conference on Rehabilitation Robotics (ICORR)
- Publisher
- IEEE
- Published
- 2015-08
- Pages
- 131-138
- ISSN
- 1945-7898 (ISSN-L)
- OpenAlex
- W1633785340
- Cited by
- 99
- References
- 9
- FWCI
- 20.39
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.