The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Stabilization of a power system with a distributed generator by a Virtual Synchronous Generator function
Abstract
The power capacity of distributed generators such as photovoltaic and wind turbine is growing, many of distributed generators are connected to a grid by inverters. The inverters are controlled by a PLL (Phase Locked Loop) in order to be synchronized with power system frequency. Power system will become unstable, if the capacity of inverter-connected-type distributed generators becomes larger and larger, because inverter frequency is controlled to follow the grid frequency. The concept of "Virtual Synchronous Generator" (VSG), which is to control inverters to behave like a synchronous generator, has been proposed. VSG has virtual inertia which is realized by an energy storage device to pretend rotor's inertia. In this paper, the control scheme of VSG is investigated which is based on the swing equation of a synchronous generator. Numerical simulation results show both ride-through capability of voltage dip and enhancement ability of grid stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beck, H.-P., & Hesse, R. (2007) · 2007 9th International Conference on Electrical Power Quality and Utilisation · doi:10.1109/epqu.2007.4424220 · Cited by 1,097
Virtual synchronous generators
Driesen, J., & Visscher, K. (2008) · 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century · doi:10.1109/pes.2008.4596800 · Cited by 763
Grid tied converter with virtual kinetic storage
van Wesenbeeck, M. P. N., de Haan, S. W. H., Varela, P., & Visscher, K. (2009) · 2009 IEEE Bucharest PowerTech · doi:10.1109/ptc.2009.5282048 · Cited by 285
Static synchronous generators for distributed generation and renewable energy
Zhong, Q.-C., & Weiss, G. (2009) · 2009 IEEE/PES Power Systems Conference and Exposition · doi:10.1109/psce.2009.4840013 · Cited by 206
Cited by
Liu, J., Miura, Y., & Ise, T. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465852 · Cited by 1,243
Self-citationEmerging Power Quality Challenges Due to Integration of Renewable Energy Sources
Liang, X. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2626253 · Cited by 935
Virtual synchronous generators: A survey and new perspectives
Bevrani, H., Ise, T., & Miura, Y. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.07.009 · Cited by 837
Self-citationMicrogrid Stability Definitions, Analysis, and Examples
Farrokhabadi, M., Canizares, C. A., Simpson-Porco, J. W., Nasr, E., Fan, L., Mendoza-Araya, P. A., Tonkoski, R., Tamrakar, U., Hatziargyriou, N., Lagos, D., et al. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2925703 · Cited by 752
D’Arco, S., Suul, J. A., & Fosso, O. B. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2015.01.001 · Cited by 704
Virtual Inertia: Current Trends and Future Directions
Tamrakar, U., Shrestha, D., Maharjan, M., Bhattarai, B., Hansen, T., & Tonkoski, R. (2017) · Applied Sciences · doi:10.3390/app7070654 · Cited by 640
D'Arco, S., & Suul, J. A. (2013) · 2013 IEEE Grenoble Conference · doi:10.1109/ptc.2013.6652456 · Cited by 443
Synchronous Generator Emulation Control Strategy for Voltage Source Converter (VSC) Stations
Guan, M., Pan, W., Zhang, J., Hao, Q., Cheng, J., & Zheng, X. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2384498 · Cited by 432
Bajaj, M., & Singh, A. K. (2020) · International Journal of Energy Research · doi:10.1002/er.4847 · Cited by 324
Limitations, challenges, and solution approaches in grid‐connected renewable energy systems
Basit, M. A., Dilshad, S., Badar, R., & Sami ur Rehman, S. M. (2020) · International Journal of Energy Research · doi:10.1002/er.5033 · Cited by 305
A comprehensive review of virtual synchronous generator
Cheema, K. M. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2020.106006 · Cited by 288
Evaluation of Virtual Inertia Control Strategies for MMC-based HVDC Terminals by P-HiL Experiments
D'Arco, S., Nguyen, T. T., & Suul, J. A. (2019) · IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2019.8927704 · Cited by 12
Metadata
- Authors
- Sakimoto, K., Miura, Y., & Ise, T.
- Venue
- 8th International Conference on Power Electronics - ECCE Asia
- Publisher
- IEEE
- Published
- 2011-05
- Pages
- 1498-1505
- OpenAlex
- W2116057333
- Cited by
- 327
- References
- 4
- FWCI
- 13.42
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.