The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A soft wearable robotic device for active knee motions using flat pneumatic artificial muscles
Abstract
We present the design of a soft wearable robotic device composed of elastomeric artificial muscle actuators and soft fabric sleeves, for active assistance of knee motions. A key feature of the device is the two-dimensional design of the elastomer muscles that not only allows the compactness of the device, but also significantly simplifies the manufacturing process. In addition, the fabric sleeves make the device lightweight and easily wearable. The elastomer muscles were characterized and demonstrated an initial contraction force of 38N and maximum contraction of 18mm with 104kPa input pressure, approximately. Four elastomer muscles were employed for assisted knee extension and flexion. The robotic device was tested on a 3D printed leg model with an articulated knee joint. Experiments were conducted to examine the relation between systematic change in air pressure and knee extension-flexion. The results showed maximum extension and flexion angles of 95° and 37°, respectively. However, these angles are highly dependent on underlying leg mechanics and positions. The device was also able to generate maximum extension and flexion forces of 3.5N and 7N, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement and modeling of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.481753 · Cited by 1,589 · cited 1×
“In conventional design, such as traditional McKibben muscles [14], straightfiber embedded rubber muscles [15], and pleated pneumatic muscles [16], a certain volume of an air chamber must exist in the structure although it is not actuated.”
BackgroundBiomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation
Park, Y.-L., Chen, B.-R., Pérez-Arancibia, N. O., Young, D., Stirling, L., Wood, R. J., Goldfield, E. C., & Nagpal, R. (2014) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/1/016007 · Cited by 497 · cited 2×
“Such systems include active soft orthotic devices for assistance of ankle [7], [8] and knee [9], [10] motions, a compliant exosuit for improved metabolic energy efficiency through active gait assistance [11], and upper extremity rehabilitation with cable-driven [12] and pneumatic muscle [13] actuations.”
BackgroundSelf-citationA lightweight soft exosuit for gait assistance
Wehner, M., Quinlivan, B., Aubin, P. M., Martinez-Villalpando, E., Baumann, M., Stirling, L., Holt, K., Wood, R., & Walsh, C. (2013) · 2013 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2013.6631046 · Cited by 361
Self-citation
Research works printed but not linked: 25
- 10.1109/JSEN.2012.2200790 · DOI · Paper page
- 10.1016/0021-9290(92)90271-2 · doi:10.1016/0021-9290(92)90271-2
- 10.1016/0021-9290(94)90003-5 · doi:10.1016/0021-9290(94)90003-5
- 10.1177/1045389X06063462 · DOI
- 10.1080/14399776.2001.10781119 · DOI · Paper page
- 10.1109/TNSRE.2010.2047116 · DOI
- 10.1109/IROS.2012.6385786 · DOI
- 10.1063/1.4767217 · DOI
- 10.1088/0960-1317/20/12/125029 · DOI · Paper page
- 10.1109/JSEN.2013.2272320 · DOI · Paper page
- 10.1109/ICRA.2013.6631337 · DOI
- 10.1109/ICSENS.2013.6688298 · DOI
- 10.1016/j.cis.2005.05.002 · DOI
- 10.1016/S0266-3538(00)00241-4 · DOI · Paper page
- 10.1021/nl102398w · DOI
- 10.1016/j.mechmachtheory.2007.03.003 · DOI · Paper page
- park, 2013, Networked bio-inspired modules for sensorimotor control of wearable cyberphysical devices, Proc Int Conf Comput Network Commun (ICNC), 92
- 10.1109/MSPEC.2005.1515961 · DOI · Paper page
- 10.1007/s11665-011-9858-7 · DOI
- 10.1108/01439910910980141 · DOI · Paper page
- 10.1109/TNSRE.2007.903919 · DOI · Paper page
- 10.1117/12.544510 · DOI
- ferris, 2005, An ankle-foot orthosis powered by artificial peumatic muscles, J Appl Biomech, 21, 189, 10.1123/jab.21.2.189 · DOI · Paper page
- 10.1109/IROS.2012.6386158 · DOI
- 10.1109/BioRob.2012.6290903 · DOI
Cited by
Polygerinos, P., Correll, N., Morin, S. A., Mosadegh, B., Onal, C. D., Petersen, K., Cianchetti, M., Tolley, M. T., & Shepherd, R. F. (2017) · Advanced Engineering Materials · doi:10.1002/adem.201700016 · Cited by 1,063
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Soft robotic devices for hand rehabilitation and assistance: a narrative review
Chu, C.-Y., & Patterson, R. M. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0350-6 · Cited by 320
Pouch Motors: Printable Soft Actuators Integrated with Computational Design
Niiyama, R., Sun, X., Sung, C., An, B., Rus, D., & Kim, S. (2015) · Soft Robotics · doi:10.1089/soro.2014.0023 · Cited by 318
Pneumatic Energy Sources for Autonomous and Wearable Soft Robotics
Wehner, M., Tolley, M. T., Mengüç, Y., Park, Y.-L., Mozeika, A., Ding, Y., Onal, C., Shepherd, R. F., Whitesides, G. M., & Wood, R. J. (2014) · Soft Robotics · doi:10.1089/soro.2014.0018 · Cited by 284
Self-citation
Metadata
- Authors
- Park, Y.-L., Santos, J., Galloway, K. G., Goldfield, E. C., & Wood, R. J.
- Venue
- 2014 IEEE International Conference on Robotics and Automation (ICRA)
- Publisher
- IEEE
- Published
- 2014-05
- Pages
- 4805-4810
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2049292590
- Cited by
- 163
- References
- 4
- FWCI
- 17.35
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.