Abstract
Although the first implantable glucose sensors were developed a few decades ago, there is still no glucose sensor that can work reliably and for a long period of time after implantation. This loss of function in vivo is caused by events that affect the sensor itself (e.g. degradation, fouling...), as well as by changes in the tissue surrounding the sensor, caused by the implantation. Therefore, in order to develop a reliable implantable glucose sensor that will remain functional for a long time in vivo, it is critical to study and control the effects of the biological environment on the sensor itself, as well as to control the tissue reactions to the sensor. Examples of such studies are described in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hickey, T., Kreutzer, D., Burgess, D. J., & Moussy, F. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00291-5 · Cited by 268
Self-citationIn vitro and in vivo mineralization of Nafion membrane used for implantable glucose sensors
Mercado, R. C., & Moussy, F. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00112-7 · Cited by 73
Self-citation
Cited by
Hydrogel interfaces for merging humans and machines
Yuk, H., Wu, J., & Zhao, X. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00483-4 · Cited by 661
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Xie, X., Doloff, J. C., Yesilyurt, V., Sadraei, A., McGarrigle, J. J., Omami, M., Veiseh, O., Farah, S., Isa, D., Ghani, S., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0273-3 · Cited by 235
“6 23 The 34 To combat such responses, which can interfere with sensing and lead to device failure, surface modifications 35 or drug delivery systems 36,37 have been developed to enhance their biocompatibility.”
Synthesis and Performance of Novel Hydrogels Coatings for Implantable Glucose Sensors
Wang, C., Yu, B., Knudsen, B., Harmon, J., Moussy, F., & Moussy, Y. (2008) · Biomacromolecules · doi:10.1021/bm701102y · Cited by 63
Self-citationDang, T. T., Bratlie, K. M., Bogatyrev, S. R., Chen, X. Y., Langer, R., & Anderson, D. G. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.02.048 · Cited by 38
Metadata
- Authors
- Moussy, F.
- Venue
- Proceedings of IEEE Sensors
- Publisher
- IEEE
- Published
- 2003-06-25
- Volume
- 1
- Pages
- 270-273
- ISSN
- 1930-0395 (ISSN-L)
- OpenAlex
- W1892732008
- Cited by
- 19
- References
- 2
- FWCI
- 1.30
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implantable glucose sensor: progress and problems. https://app.cochat.ai/papers/10.1109/icsens.2002.1037097
- The paper
- Moussy, F. (2003). Implantable glucose sensor: progress and problems. Proceedings of IEEE Sensors. https://doi.org/10.1109/icsens.2002.1037097
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.