MagIC System: a New Textile-Based Wearable Device for Biological Signal Monitoring. Applicability in Daily Life and Clinical Setting
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The paper presents a new textile-based wearable system for the unobtrusive recording of cardiorespiratory and motion signals during spontaneous behavior along with the first results concerning the application of this device in daily life and in a clinical environment. The system, called MagIC (Maglietta Interattiva Computerizzata), is composed of a vest, including textile sensors for detecting ECG and respiratory activity, and a portable electronic board for motion detection, signal preprocessing and wireless data transmission to a remote monitoring station. The MagIC system has been tested in freely moving subjects at work, at home, while driving and cycling and in microgravity condition during a parabolic flight. Applicability of the system in cardiac in-patients is now under evaluation. Preliminary data derived from recordings performed on patients in bed and during physical exercise showed 1) good signal quality over most of the monitoring periods, 2) a correct identification of arrhythmic events, and 3) a correct estimation of the average beat-by-beat heart rate. These positive results supports further developments of the MagIC system, aimed at tuning this approach for a routine use in clinical practice and in daily life.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smart fabric, or "wearable clothing"
Post, E. R., & Orth, M. (2002) · Digest of Papers. First International Symposium on Wearable Computers · doi:10.1109/iswc.1997.629937 · Cited by 180 · cited 1×
“unobtrusive monitoring of biological signals through textile sensors [ 1 ].”
BackgroundDe Rossi, D., Della Santa, A., & Mazzoldi, A. (1999) · Materials Science and Engineering: C · doi:10.1016/s0928-4931(98)00069-1 · Cited by 160 · cited 1×
“Since then, several research groups in the world [2, 3, 4 ], including our technological laboratory, have been working in the attempt to translate this innovative concept into a real device.”
Background
Cited by
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296
“MagIC [32], developed by researchers in Milan, Italy, is a washable sensorized vest including fully woven textile sensors for ECG and respiration rate monitoring and a portable electronic board, which evaluates the wearer’s motion level and is responsible for signal preprocessing and data transmission through Bluetoot…”
BackgroundA survey on ambient-assisted living tools for older adults
Rashidi, P., & Mihailidis, A. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2012.2234129 · Cited by 1,128
A review of smart homes—Present state and future challenges
Chan, M., Estève, D., Escriba, C., & Campo, E. (2008) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2008.02.001 · Cited by 1,007
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919
“) or in a clinical environment, with the advantage of minimizing discomfort and interference with normal human activities [1].”
BackgroundA Survey on Ambient Intelligence in Healthcare
Acampora, G., Cook, D. J., Rashidi, P., & Vasilakos, A. V. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2262913 · Cited by 630
Smart textiles: Challenges and opportunities
Cherenack, K., & van Pieterson, L. (2012) · Journal of Applied Physics · doi:10.1063/1.4742728 · Cited by 602
Smart Vest: Wearable multi-parameter remote physiological monitoring system
Pandian, P. S., Mohanavelu, K., Safeer, K. P., Kotresh, T. M., Shakunthala, D. T., Gopal, P., & Padaki, V. C. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.05.014 · Cited by 423
Challenges and Research Directions in Medical Cyber–Physical Systems
Lee, I., Sokolsky, O., Chen, S., Hatcliff, J., Jee, E., Kim, B., King, A., Mullen-Fortino, M., Park, S., Roederer, A., et al. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165270 · Cited by 373
Wang, Z., Yang, Z., & Dong, T. (2017) · Sensors · doi:10.3390/s17020341 · Cited by 355
Wearable Medical Systems for p-Health
Teng, X.-F., Zhang, Y.-T., Poon, C. C. Y., & Bonato, P. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008248 · Cited by 310
“piratory and motion signals during daily life and in a clinical environment on patients with different cardiovascular conditions [86]; and the MyHeart wearable monitoring system that focuses on integration of unobtrusive sensors into everyday gar-”
BackgroundWearable Wireless Health Monitoring: Current Developments, Challenges, and Future Trends
Soh, P. J., Vandenbosch, G. A. E., Mercuri, M., & Schreurs, D. M. M.-P. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2015.2394021 · Cited by 253
“LEMO Connector for BP Monitor Event Button Liquid Crystal Display Buzzer AAA Battery Compartment LEMO Connector for Temperature Sensor LEMO Connector for ECG/Respiratory Electrodes On/Off Switch RS-232 Port May 2015 63 A washable sensor vest aimed at home monitoring applications for elderly people or cardiac patients…”
BackgroundMethodInfluentialLmberis, A., & Dittmar, A. (2007) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2007.364926 · Cited by 194
“➤ MagIC [20], is a sensorized vest including fully woven textile sensors for ECG and respiratory frequency detection and a portable electronic board for motion assessment, signal preprocessing, and Bluetooth connection for data transmission.”
BackgroundValidation of the Hexoskin wearable vest during lying, sitting, standing, and walking activities
Villar, R., Beltrame, T., & Hughson, R. L. (2015) · Applied Physiology Nutrition and Metabolism · doi:10.1139/apnm-2015-0140 · Cited by 178
Recent Developments in Home Sleep-Monitoring Devices
Kelly, J. M., Strecker, R. E., & Bianchi, M. T. (2012) · ISRN Neurology · doi:10.5402/2012/768794 · Cited by 180
“ECG [30].”
López, G., Custodio, V, & Moreno, J. I. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2058812 · Cited by 173
Features and application of wearable biosensors in medical care
Ajami, S., & Teimouri, F. (2015) · Journal of Research in Medical Sciences · doi:10.4103/1735-1995.172991 · Cited by 159
Kroll, R. R., Boyd, J. G., & Maslove, D. M. (2016) · Journal of Medical Internet Research · doi:10.2196/jmir.6025 · Cited by 123
“A number of different wearable sensors have been developed, which generate data that could potentially be useful in health care [7-9].”
BackgroundUse of wearable devices for post-discharge monitoring of ICU patients: a feasibility study
for the WEARable Information Technology for hospital INpatients (WEARIT-IN) study group, Kroll, R. R., McKenzie, E. D., Boyd, J. G., Sheth, P., Howes, D., Wood, M., & Maslove, D. M. (2017) · Journal of Intensive Care · doi:10.1186/s40560-017-0261-9 · Cited by 69
Ambulatory cardiac bio-signals: From mirage to clinical reality through a decade of progress
Periyaswamy, T., & Balasubramanian, M. (2019) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2019.07.007 · Cited by 14
Metadata
- Authors
- Di Rienzo, M., Rizzo, F., Parati, G., Brambilla, G., Ferratini, M., & Castiglioni, P.
- Venue
- 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference
- Publisher
- IEEE
- Published
- 2005
- Volume
- 2005
- Pages
- 7167-7169
- OpenAlex
- W2134529602
- Cited by
- 201
- References
- 2
- FWCI
- 11.65
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.