Relative to direct haptic feedback, remote vibrotactile feedback improves but slows object manipulation
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Most prosthetic hand users are limited to visual feedback of movement performance. To characterize the benefit of vibrotactile feedback for a task that lacks haptic feedback, a virtual environment was used to experimentally manipulate visual, task-relevant haptic, and remote vibrotactile feedback on simple object manipulation for unimpaired subjects. The combination of visual and remote vibrotactile feedback was compared to visual feedback alone, and to simultaneous visual and direct haptic feedback to represent ideal performance. Visual and vibrotactile feedback resulted in improvement of most performance variables including difficulty ratings relative to visual feedback alone. However addition of sensory cues to visual feedback increased trial times and the increase was steeper for vibrotactile than for haptic feedback. Specifically, during vibrotactile feedback the velocity did not change, but the duration of execution increased due to improved performance, resulting in increased trial times. This result suggests future exploration of performance improvement and execution speed for augmented sensory feedback.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Age differences in short-term retention of rapidly changing information.
Kirchner, W. K. (1958) · Journal of Experimental Psychology · doi:10.1037/h0043688 · Cited by 1,798 · cited 1×
“The cognitive load consisted of an auditory 2-back test, in which participants listened to random digit strings during experimentation and were asked to respond verbally by identifying any numbers repeated with only one intervening number [ 15 ].”
MethodElectrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Ehrsson, H. H., Holmes, N. P., & Passingham, R. E. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.0800-05.2005 · Cited by 784
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519
Results of an internet survey of myoelectric prosthetic hand users
Pylatiuk, C., Schulz, S., & Döderlein, L. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640601061265 · Cited by 257
The benefit of force feedback in surgery: Examination of blunt dissection
Wagner, C. R., Stylopoulos, N., Jackson, P. G., & Howe, R. D. (2007) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.16.3.252 · Cited by 169
Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156
Cited by
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Clemente, F., D'Alonzo, M., Controzzi, M., Edin, B. B., & Cipriani, C. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2500586 · Cited by 209
Vibro- and Electrotactile User Feedback on Hand Opening for Myoelectric Forearm Prostheses
Witteveen, H. J. B., Droog, E. A., Rietman, J. S., & Veltink, P. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2200678 · Cited by 150
Gonzalez, J., Soma, H., Sekine, M., & Yu, W. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-33 · Cited by 87
Stepp, C. E., & Matsuoka, Y. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2168981 · Cited by 28
“Although the addition of a cognitive task did not have an effect on box displacements, it led to decreased velocities and increased difficulty ratings, agreeing with previous work [22].”
InfluentialSelf-citation
Metadata
- Authors
- Stepp, C. E., & Matsuoka, Y.
- Venue
- 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
- Publisher
- IEEE
- Published
- 2010-08
- Volume
- 2010
- Pages
- 2089-2092
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W1964730801
- Cited by
- 42
- References
- 7
- FWCI
- 21.39
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relative to direct haptic feedback, remote vibrotactile feedback improves but slows object manipulation. https://app.cochat.ai/papers/10.1109/iembs.2010.5626120
- The paper
- Stepp, C. E., & Matsuoka, Y. (2010). Relative to direct haptic feedback, remote vibrotactile feedback improves but slows object manipulation. 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2010.5626120
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.