A Review of Obstructive Sleep Apnea Detection Approaches
The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.
Abstract
Sleep disorders are a common health condition that can affect numerous aspects of life. Obstructive sleep apnea is one of the most common disorders and is characterized by a reduction or cessation of airflow during sleep. In many countries, this disorder is usually diagnosed in sleep laboratories, by polysomnography, which is an expensive procedure involving much effort for the patient. Multiple systems have been proposed to address this situation, including performing the examination and analysis in the patient's home, using sensors to detect physiological signals that are automatically analyzed by algorithms. However, the precision of these devices is usually not enough to provide clinical diagnosis. Therefore, the objective of this review is to analyze already existing algorithms that have not been implemented on hardware but have had their performance verified by at least one experiment that aims to detect obstructive sleep apnea to predict trends. The performance of different algorithms and methods for apnea detection through the use of different sensors (pulse oximetry, electrocardiogram, respiration, sound, and combined approaches) has been evaluated. 84 original research articles published from 2003 to 2017 with the potential to be promising diagnostic tools have been selected to cover multiple solutions. This paper could provide valuable information for those researchers who want to carry out a hardware implementation of potential signal processing algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
International Classification of Sleep Disorders-Third Edition
Sateia, M. J. (2014) · Chest · doi:10.1378/chest.14-0970 · Cited by 3,860 · cited 2×
“patient has reported the indicated symptoms and presents 5 or more obstructive respiratory events per hour of sleep during a PSG recording [1].”
BackgroundPrevalence of obstructive sleep apnea in the general population: A systematic review
Senaratna, C. V., Perret, J. L., Lodge, C. J., Lowe, A. J., Campbell, B. E., Matheson, M. C., Hamilton, G. S., & Dharmage, S. C. (2017) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2016.07.002 · Cited by 2,581 · cited 1×
“index (AHI) of greater than or equal to 15 events/hour, with males being more affected than females, and this prevalence becomes more relevant with increasing age [2].”
BackgroundThe Sleep Heart Health Study: Design, Rationale, and Methods
(1997) · Sleep · doi:10.1093/sleep/20.12.1077 · Cited by 1,331 · cited 1×
“The databases referenced are: PhysioNet apnea-ECG [15]; University College Dublin Sleep Apnea [16]; Sleep Heart Health Study [17]; MITBIH polysomnography database [18]; ScalingUpScientificDiscovery in Sleep [19].”
MethodHome Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Penzel, T., Moody, G. B., Mark, R. G., Goldberger, A. L., & Peter, J. H. (2002) · Computers in Cardiology 2000. Vol.27 (Cat. 00CH37163) · doi:10.1109/cic.2000.898505 · Cited by 446 · cited 1×
“The databases referenced are: PhysioNet apnea-ECG [15]; University College Dublin Sleep Apnea [16]; Sleep Heart Health Study [17]; MITBIH polysomnography database [18]; ScalingUpScientificDiscovery in Sleep [19].”
MethodSelf-citationObstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427 · cited 2×
“[6], named SCOPER, being divided into six categories: sleep; cardiovascular; oximetry; position; effort; respiratory.”
MethodKhandoker, A. H., Palaniswami, M., & Karmakar, C. K. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2004495 · Cited by 367 · cited 1×
“[68] used 14 levels of Daubechies wavelets to decompose the RR and EDR signals.”
MethodChesson, A. L., Berry, R. B., & Pack, A. (2003) · Sleep · doi:10.1093/sleep/26.7.907 · Cited by 344 · cited 1×
“on four levels, from the reference test (PSG minimum of seven channels) to the portable devices with one or two channels [5].”
BackgroundScaling Up Scientific Discovery in Sleep Medicine: The National Sleep Research Resource
Dean, D. A., Goldberger, A. L., Mueller, R., Kim, M., Rueschman, M., Mobley, D., Sahoo, S. S., Jayapandian, C. P., Cui, L., Morrical, M. G., et al. (2016) · Sleep · doi:10.5665/sleep.5774 · Cited by 309 · cited 1×
“The databases referenced are: PhysioNet apnea-ECG [15]; University College Dublin Sleep Apnea [16]; Sleep Heart Health Study [17]; MITBIH polysomnography database [18]; ScalingUpScientificDiscovery in Sleep [19].”
MethodReal-time sleep apnea detection by classifier combination
Xie, B., & Minn, H. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2188299 · Cited by 294 · cited 1×
“A combination of oximetry and ECG was presented by Xie and Minn [94].”
Development of the polysomnographic database on CD‐ROM
Ichimaru, Y., & Moody, G. B. (1999) · Psychiatry and Clinical Neurosciences · doi:10.1046/j.1440-1819.1999.00527.x · Cited by 292 · cited 1×
“The databases referenced are: PhysioNet apnea-ECG [15]; University College Dublin Sleep Apnea [16]; Sleep Heart Health Study [17]; MITBIH polysomnography database [18]; ScalingUpScientificDiscovery in Sleep [19].”
MethodSong, C., Liu, K., Zhang, X., Chen, L., & Xian, X. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2498199 · Cited by 252 · cited 1×
“[64] to produce features that were considered to be subject-independent, implementing a learning and prediction procedure based on a discriminative”
MethodComputer based sleep recording and analysis
Penzel, T., & Conradt, R. (2000) · Sleep Medicine Reviews · doi:10.1053/smrv.1999.0087 · Cited by 235 · cited 1×
“Conradt [7] in 2000, specifically: replacement of conventional paper chart recorders; technicians should be able to introduce additional notes and observations that were performed during”
BackgroundSelf-citationLázaro, J. M., Gil, E., Vergara, J. M., & Laguna, P. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2267096 · Cited by 185 · cited 1×
“[32].”
Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography
Penzel, T., Kantelhardt, J. W., Bartsch, R. P., Riedl, M., Kraemer, J. F., Wessel, N., Garcia, C., Glos, M., Fietze, I., & Schöbel, C. (2016) · Frontiers in Physiology · doi:10.3389/fphys.2016.00460 · Cited by 174
Self-citationSleep Apnea Screening by Autoregressive Models From a Single ECG Lead
Mendez, M. O., Bianchi, A. M., Matteucci, M., Cerutti, S., & Penzel, T. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2029563 · Cited by 163
Self-citationKhandoker, A. H., Gubbi, J., & Palaniswami, M. S. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2031639 · Cited by 163 · cited 1×
“[37] to decompose the ECG signal into 8 levels of detailed coefficients.”
MethodHassan, A. R. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.05.009 · Cited by 161 · cited 1×
“wavelet transformwas applied by Hassan [39] to decompose the ECG signal segments into sub-bands that were further modelled using a symmetric normal inverse Gaussian model.”
MethodNg, A. K., Koh, T. S., Baey, E., Lee, T. H., Abeyratne, U. R., & Puvanendran, K. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2007.07.010 · Cited by 160
Chen, L., Zhang, X., & Song, C. (2015) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2014.2345667 · Cited by 159 · cited 1×
“[59] applied the RR intervals for signal segmentation using an iterated cumulative sum of squares algorithm that searches for the small variation changes in time series due to OSA.”
MethodSleep stage and obstructive apneaic epoch classification using single-lead ECG
Yılmaz, B., Asyalı, M. H., Arıkan, E., Yetkin, S., & Özgen, F. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-39 · Cited by 157 · cited 1×
“[54] where the RR series was obtained from a single lead of the ECG signal using an R-peak detection technique where the R waves were differentiated by studding the curvature and”
MethodHassan, A. R., & Haque, M. A. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.12.062 · Cited by 157 · cited 1×
“The same kind of wavelet transform was used by Hassan and Haque [40] to decompose”
MethodMultivariate Analysis of Blood Oxygen Saturation Recordings in Obstructive Sleep Apnea Diagnosis
Álvarez, D., Hornero, R., Marcos, J. V., & del Campo, F. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2056924 · Cited by 153 · cited 1×
“[31].”
Sleep apnea monitoring and diagnosis based on pulse oximetery and tracheal sound signals
Yadollahi, A., Giannouli, E., & Moussavi, Z. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0674-2 · Cited by 149
Automated Recognition of Obstructive Sleep Apnea Syndrome Using Support Vector Machine Classifier
Al-Angari, H. M., & Sahakian, A. V. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2185809 · Cited by 142 · cited 1×
“Al-Angari and Sahakian [101] combined oximetry, thoracic and abdominal respiratory effort signals with ECG signals.”
BackgroundAutomated detection of obstructive sleep apnoea at different time scales using the electrocardiogram
Chazal, P. D., Penzel, T., & Heneghan, C. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/015 · Cited by 138 · cited 1×
“[55] and Yılmaz et al.”
Self-citationDevelopment of a Screening Tool for Sleep Disordered Breathing in Children Using the Phone Oximeter™
Garde, A., Dehkordi, P., Karlen, W., Wensley, D., Ansermino, J. M., & Dumont, G. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0112959 · Cited by 135 · cited 1×
“[33], with OSA classification performed using LDA.”
An Online Sleep Apnea Detection Method Based on Recurrence Quantification Analysis
Nguyen, H. D., Wilkins, B. A., Cheng, Q., & Benjamin, B. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2292928 · Cited by 133 · cited 1×
“[58].”
Predicting sleep apnoea syndrome from heart period: a time-frequency wavelet analysis
Roche, F., Pichot, V., Sforza, E. A., Court‐Fortune, I., Duverney, D., Costes, F., Garet, M., & Barthélemy, J. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00104902 · Cited by 116 · cited 1×
“[49] where the wavelet transform was used to decompose the signal and the classification was performed using a classification tree, de-”
MethodZamarrón, C., Gudé, F., González‐Barcala, F. J., Rodriguez, J. R., & Romero, P. V. (2003) · CHEST Journal · doi:10.1378/chest.123.5.1567 · Cited by 107 · cited 1×
“[92] where a combination of these”
Álvarez, D., Hornero, R., Abásolo, D., Campo, F. D., & Zamarrón, C. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/006 · Cited by 105 · cited 1×
“[21] applied two non-linear methods to determine which would be better to further improve the OSA detection capability.”
MethodClassifying obstructive sleep apnea using smartphones
Mardini, M., Aloul, F., Sagahyroon, A. A., & Al-Husseini, L. (2014) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2014.07.004 · Cited by 99 · cited 1×
“applications, as for example [11], [12].”
Cheng, M.-W., Jifara, W., Jiang, F., Khan, A., & Liu, S. (2017) · IEEE International Conference on Computational Science and Engineering (CSE) and IEEE International Conference on Embedded and Ubiquitous Computing (EUC) · doi:10.1109/cse-euc.2017.220 · Cited by 98 · cited 1×
“[60] to classify the RR intervals.”
Automatic Detection of Obstructive Sleep Apnea Using Speech Signals
Goldshtein, E., Tarasiuk, A., & Zigel, Y. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2100096 · Cited by 95 · cited 1×
“[87]where OSA was detected by analyzing particular speech signal properties.”
BackgroundMulti-feature snore sound analysis in obstructive sleep apnea–hypopnea syndrome
Karunajeewa, A. S., Abeyratne, U. R., & Hukins, C. (2010) · Physiological Measurement · doi:10.1088/0967-3334/32/1/006 · Cited by 91 · cited 1×
“[86].”
Single Sensor Techniques for Sleep Apnea Diagnosis Using Deep Learning
Pathinarupothi, R. K., Dhara Prathap, J., Rangan, E. S., Gopalakrishnan, E. A., Vinaykumar, R., & Soman, K. P. (2017) · IEEE International Conference on Healthcare Informatics (ICHI) · doi:10.1109/ichi.2017.37 · Cited by 89 · cited 1×
“[35] with 60 neurons in the input layer (the oximetry signal has 60 samples, each corresponding to a second of data) and 32 memory blocks, with”
BackgroundInstantaneous heart rate as a robust feature for sleep apnea severity detection using deep learning
Pathinarupothi, R. K., Vinaykumar, R., Rangan, E. S., Gopalakrishnan, E. A., & Soman, K. P. (2017) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2017.7897263 · Cited by 89 · cited 1×
“[61] to feed a 2-layer stacked LSTM-RNN with two memory blocks in each layer.”
MethodDetection of Sleep Apnea from surface ECG based on features extracted by an Autoregressive Model
Mendez, M. O., Ruini, D. D., Villantieri, O. P., Matteucci, M., Penzel, T., Cerutti, S., & Bianchi, A. M. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353742 · Cited by 89 · cited 1×
“[63], with the PSD of the RR intervals series being evaluated by a bivariate autoregressive”
MethodSelf-citationSpO2 based sleep apnea detection using deep learning
Mostafa, S. S., Mendonça, F., Morgado‐Dias, F., & Ravelo-García, A. G. (2017) · IEEE International Conference on Intelligent Engineering Systems (INES) · doi:10.1109/ines.2017.8118534 · Cited by 87 · cited 1×
“[34].”
Self-citationDetection of obstructive sleep apnea through ECG signal features
Almazaydeh, L. H., Elleithy, K. M., & Faezipour, M. (2012) · IEEE International Conference on Electro Information Technology · doi:10.1109/eit.2012.6220730 · Cited by 84 · cited 2×
“[3]”
BackgroundMarcos, J. V., Hornero, R., Álvarez, D., del Campo, F., & Zamarrón, C. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.05.010 · Cited by 81
Koley, B. L., & Dey, D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2282337 · Cited by 81 · cited 1×
“The oronasal airflow, after being filtered and segmented, was also used by Koley and Dey [72],”
MethodA REVIEW OF ECG-BASED DIAGNOSIS SUPPORT SYSTEMS FOR OBSTRUCTIVE SLEEP APNEA
Faust, O., Acharya, U. R., Ng, E. Y. K., & Fujita, H. (2016) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519416400042 · Cited by 79 · cited 1×
“[13] (time frame from 2002 to 2015) analyzing ECG based algorithms, or classification techniques such as the review developed by Pombo”
MethodGonzález, M., Navarro-Mesa, J. L., Juliá-Serdà, G., Kraemer, J. F., Wessel, N., & Ravelo-García, A. G. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.10.004 · Cited by 78
ECG signal analysis for the assessment of sleep-disordered breathing and sleep pattern
Kesper, K., Canisius, S., Penzel, T., Ploch, T., & Cassel, W. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0853-9 · Cited by 78
Self-citationSleep Apnea Event Detection from Nasal Airflow Using Convolutional Neural Networks
Haidar, R., Koprinska, I., & Jeffries, B. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-70139-4_83 · Cited by 75 · cited 1×
“[79].”
Khandoker, A. H., Karmakar, C. K., & Palaniswami, M. S. (2009) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2008.11.003 · Cited by 75 · cited 1×
“[69] as inputs to the SVM clas-”
Pombo, N. G. C. C., García, N. M., & Bousson, K. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.01.001 · Cited by 72
Marcos, J. V., Hornero, R., Álvarez, D., del Campo, F., & Aboy, M. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0646-6 · Cited by 71
Marcos, J. V., Hornero, R., Álvarez, D., del Campo, F., Zamarrón, C., & Lopez, M. (2008) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2008.05.006 · Cited by 71 · cited 1×
“[29] where”
Spectral analysis of electroencephalogram and oximetric signals in obstructive sleep apnea diagnosis
Álvarez, D., Hornero, R., Marcos, J. V., del Campo, F., & López, M. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334905 · Cited by 71 · cited 1×
“[93].”
A Neural Network System for Detection of Obstructive Sleep Apnea Through SpO2 Signal Features
Almazaydeh, L. H., Faezipour, M., & Elleithy, K. M. (2012) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2012.030502 · Cited by 68 · cited 1×
“[27].”
Probabilistic neural network approach for the detection of SAHS from overnight pulse oximetry
Morillo, D., & Gross, N. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0995-4 · Cited by 67 · cited 1×
“A probabilistic neural network (NN) was used byMorillo and Gross [26] as a classifier with five neurons on the input layer analyzing the OSI, with falls in SpO2 of greater than 4% on a”
MethodSmruthy, A., & Suchetha, M. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2690805 · Cited by 67 · cited 2×
“[45] and Smruthy and Suchetha [41].”
MethodOxygen Saturation and RR Intervals Feature Selection for Sleep Apnea Detection
Ravelo-García, A. G., Kraemer, J. F., Navarro-Mesa, J. L., Hernández-Pérez, E., Navarro-Esteva, J., Juliá-Serdà, G., Penzel, T., & Wessel, N. (2015) · Entropy · doi:10.3390/e17052932 · Cited by 66 · cited 1×
“[97].”
Self-citationAutomatic screening of Obstructive Sleep Apnea from single-lead Electrocardiogram
Hassan, A. R. (2015) · International Conference on Electrical Engineering and Information Communication Technology · doi:10.1109/iceeict.2015.7307522 · Cited by 66
The use of tracheal sounds for the diagnosis of sleep apnoea
Penzel, T., & Sabil, A. (2017) · Breathe · doi:10.1183/20734735.008817 · Cited by 65 · cited 1×
“tracheal sounds was analyzed by Penzel and Sabil [90], being verified that when recorded with an appropriate sensor, com-”
MethodSelf-citationQuiceno-Manrique, A. F., Alonso, J. B., Travieso, C. M., Ferrer, M. A., & Castellanos-Dominguez, G. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333736 · Cited by 62 · cited 1×
“[43] employed an analysis based on the HRV, extracting features from time-frequency distributions, belonging to Cohen’s class, by means of spectral sub-band centroids and linear filter Cepstral coefficients.”
MethodReal-Time Automatic Apneic Event Detection Using Nocturnal Pulse Oximetry
Jung, D. W., Hwang, S. H., Cho, J. G., Choi, B. H., Baek, H. J., Lee, Y. J., Jeong, D.-U., & Park, K. S. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2715405 · Cited by 61 · cited 1×
“[20] taking three points into consideration.”
Sleep apnea classification based on respiration signals by using ensemble methods
Avcı, C., & Akbaş, A. (2015) · Bio-Medical Materials and Engineering · doi:10.3233/bme-151470 · Cited by 59 · cited 1×
“Same family of wavelet was employed by Avci and Akbas [77] to decompose the airflow signal.”
MethodSleep apnea classification using ECG-signal wavelet-PCA features
Rachim, V. P., Li, G., & Chung, W. (2014) · Bio-Medical Materials and Engineering · doi:10.3233/bme-141106 · Cited by 57
Gutiérrez‐Tobal, G. C., Hornero, R., Álvarez, D., Marcos, J. V., & del Campo, F. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/7/1261 · Cited by 56 · cited 1×
“[74], using features from both airflow and respiratory rate variability (RRV) signals.”
MethodBenavides, A. M., Pozo, R. F., Toledano, D. T., Murillo, J. L. B., Gonzalo, E. L., & Gómez, L. A. H. (2013) · Computer Speech & Language · doi:10.1016/j.csl.2013.08.002 · Cited by 56 · cited 1×
“[89] analyzed”
Ravelo-García, A. G., Navarro-Mesa, J. L., Casanova-Blancas, U., González, M., Quintana-Morales, P. J., Guerra-Moreno, I., Canino-Rodríguez, J. M., & Hernández-Pérez, E. (2015) · Entropy · doi:10.3390/e17030914 · Cited by 56 · cited 1×
“[66] to obtain features.”
Álvarez, D., Hornero, R., Marcos, J. V., & del Campo, F. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.11.009 · Cited by 54
Pozo, R. F., Murillo, J. L. B., Gómez, L. A. H., Gonzalo, E. L., Alcázar-Ramírez, J., & Toledano, D. T. (2009) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2009/982531 · Cited by 54 · cited 1×
“[88] where the speech signals were parameterized using the Mel Frequency Cepstral Coefficient (MFCC).”
MethodComputer-Assisted Diagnosis of the Sleep Apnea-Hypopnea Syndrome: A Review
Álvarez-Estévez, D., & Moret‐Bonillo, V. (2015) · Sleep Disorders · doi:10.1155/2015/237878 · Cited by 52 · cited 1×
“A review of computer-aided approaches for OSA diagnosis was presented by Alvarez-Estevez and Moret-Bonillo [8] covering papers”
MethodGutiérrez‐Tobal, G. C., Álvarez, D., Gómez‐Pilar, J., del Campo, F., & Hornero, R. (2015) · Entropy · doi:10.3390/e17010123 · Cited by 50 · cited 1×
“[48].”
Yildiz, A., Akın, M., & Poyraz, M. (2011) · Expert Systems with Applications · doi:10.1016/j.eswa.2011.04.080 · Cited by 50 · cited 1×
“[70] analysing 64 points of PSD (1 to 32 derived from HRV and 33”
BackgroundSpeech Signal and Facial Image Processing for Obstructive Sleep Apnea Assessment
Espinoza-Cuadros, F., Pozo, R. F., Toledano, D. T., Alcázar-Ramírez, J., López-Gonzalo, E., & Gómez, L. A. H. (2015) · Computational and Mathematical Methods in Medicine · doi:10.1155/2015/489761 · Cited by 49 · cited 1×
“[104].”
Apnea Detection Based on Time Delay Neural Network
Tian, J. Y., & Liu, J. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616994 · Cited by 47 · cited 1×
“A time delay NN was used by Tian and Liu [99] to distinguishing hypopnea and apnea from normal breathing, using the filtered airflow signal area and standard deviation and SpO2 desaturation level as features.”
MethodSommermeyer, D., Zou, D., Grote, L., & Hedner, J. A. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2148 · Cited by 46 · cited 1×
“[102].”
Detection of sleep apnea on a per-second basis using respiratory signals
Selvaraj, N., & Narasimhan, R. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609953 · Cited by 44
Medical Devices for Pediatric Apnea Monitoring and Therapy: Past and New Trends
Pullano, S. A., Mahbub, I., Bianco, M. G., Shamsir, S., ISLAM, S. K., Gaylord, M. S., Lorch, V., & Fiorillo, A. S. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2757899 · Cited by 43 · cited 1×
“been performed with focus on devices for home detection [6], [9], [10] and some papers focused completely on smartphone”
MethodHeterogeneous recurrence analysis of heartbeat dynamics for the identification of sleep apnea events
Cheng, C., Chen, K., & Yang, H. Y. (2016) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2016.05.006 · Cited by 43
Ravelo-García, A. G., Saavedra, P., Juliá-Serdà, G., Navarro-Mesa, J. L., Navarro-Esteva, J., Álvarez-López, X., Gapelyuk, A., Penzel, T., & Wessel, N. (2014) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.4869825 · Cited by 39 · cited 1×
“[46] employed a non-linear HRV analysis using a symbolic dynamics method applied to the RR series, transforming it into a”
MethodSelf-citationKalkbrenner, C., Eichenlaub, M., Rüdiger, S., Kropf-Sanchen, C., Rottbauer, W., & Brucher, R. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-017-1706-y · Cited by 36 · cited 1×
“[91] also analyzed the tracheal sounds, recorded by a microphone on subject’s neck.”
BackgroundPolat, K., Yosunkaya, Ş., & Güneş, S. (2008) · Journal of Medical Systems · doi:10.1007/s10916-008-9129-9 · Cited by 34 · cited 1×
“[103] to test four classifiers, specifically, C4.”
Optimization of sleep apnea detection using SpO2 and ANN
Mostafa, S. S., Carvalho, J. P., Morgado‐Dias, F., & Ravelo-García, A. G. (2017) · International Conference on Information, Communication and Automation Technologies (ICAT) · doi:10.1109/icat.2017.8171609 · Cited by 33 · cited 1×
“[30].”
Self-citationMultimodal Classification of Obstructive Sleep Apnea Using Feature Level Fusion
Memiş, G., & Sert, M. (2017) · IEEE International Conference on Semantic Computing (ICSC) · doi:10.1109/icsc.2017.87 · Cited by 32 · cited 1×
“signals was employed by Memis and Sert [96].”
MethodThommandram, A., Eklund, J., & McGregor, C. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610674 · Cited by 29 · cited 1×
“[80] where the respiratory effort signal (also called the RI sig-”
BackgroundECG Analysis for Sleep Apnea Detection
von Einem, V., Widiger, B., Joseph, G., et al. (2004) · Methods of Information in Medicine · doi:10.1055/s-0038-1633835 · Cited by 25 · cited 1×
“[47] used an LDA for classification with features based on information of four frequency bands: ULF; VLF; LF; HF.”
MethodAutomated detection of apnea and hypopnea events
Koley, B. L., & Dey, D. (2012) · International Conference on Emerging Applications of Information Technology · doi:10.1109/eait.2012.6407868 · Cited by 22 · cited 1×
“Oronasal airflow is one of themost direct indicators of breathing disorders andwas used byKoley andDey [71] to detectOSA.”
MethodRosenwein, T., Dafna, E., Tarasiuk, A., & Zigel, Y. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7320173 · Cited by 22 · cited 1×
“[82].”
Poupard, L., Philippe, C., Goldman, M. D., Sartene, R., & Mathieu, M. (2011) · Sleep And Breathing · doi:10.1007/s11325-011-0518-9 · Cited by 21 · cited 1×
“[95], using the wavelet-aggregation to quantify these variations.”
MethodÁlvarez, D., Gutiérrez‐Tobal, G. C., Vaquerizo-Villar, F., Barroso-García, V., Crespo, A., Domingo, C. A. A., del Campo, F., & Hornero, R. (2016) · Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges (GMEPE/PAHCE) · doi:10.1109/gmepe-pahce.2016.7504628 · Cited by 18 · cited 1×
“[28] where LZC, CTM, sample entropy, statistical moments in the time domain, spectral entropy and relative power”
BackgroundWenz, H., Dickhaus, H., & Maier, C. (2014) · Methods of Information in Medicine · doi:10.3414/me13-02-0043 · Cited by 16
On the use of smartphones for detecting obstructive sleep apnea
Mardini, M., Aloul, F., Sagahyroon, A. A., & Al-Husseini, L. (2013) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2013.6701674 · Cited by 11 · cited 1×
“applications, as for example [11], [12].”
Automatic Apnea Identification by Transformation of the Cepstral Domain
Travieso, C. M., Alonso, J. B., DelPozo‐Baños, M., Ticay-Rivas, J. R., & de Ipiña, K. L. (2012) · Cognitive Computation · doi:10.1007/s12559-012-9184-x · Cited by 9 · cited 1×
“[57] applying a kernel based on a hidden Markov model (HMM) over the Cepstral coefficients obtained from the RR series.”
MethodChen, L., & Zhang, X. (2015) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2015.2503284 · Cited by 6 · cited 2×
“[53], who also uses the ECG signal analysis, and by Kalkbrenner et al.”
BackgroundMethodObstructive Sleep Apnea Severity Multiclass Classification Using Analysis of Snoring Sounds
Praydas, T., Wongkittisuksa, B., & Tanthanuch, S. (2016) · Proceedings of the World Congress on Electrical Engineering and Computer Systems and Science · doi:10.11159/icbes16.142 · Cited by 6
Cited by
A Systematic Review of Detecting Sleep Apnea Using Deep Learning
Mostafa, S. S., Mendonça, F., G. Ravelo-García, A., & Morgado-Dias, F. (2019) · Sensors · doi:10.3390/s19224934 · Cited by 182
“…reviews have been performed in the field of sleep apnea detection, such as analyzing devices for home detection of obstructive sleep apnea (OSA) [26], classification methods based on respiratory and oximetry signals [26], di ff erent detection approaches [27], detection and treatment methods [28].”
BackgroundMethodSelf-citationLevy, J., Álvarez, D., Rosenberg, A. A., Alexandrovich, A., del Campo, F., & Behar, J. A. (2021) · npj Digital Medicine · doi:10.1038/s41746-020-00373-5 · Cited by 125
A Robust Interpretable Deep Learning Classifier for Heart Anomaly Detection Without Segmentation
Dissanayake, T., Fernando, T., Denman, S., Sridharan, S., Ghaemmaghami, H., & Fookes, C. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3027910 · Cited by 105
“Since the considered architecture employs Mel-Frequency Cep-stral Coefficients (MFCCs), and MFCCs have been extensively used in medical [26], speech [27] and emotion [28] domains, we also adopt MFCCs as the primary feature.”
Papini, G. B., Fonseca, P., van Gilst, M. M., Bergmans, J. W. M., Vullings, R., & Overeem, S. (2020) · Scientific Reports · doi:10.1038/s41598-020-69935-7 · Cited by 90
O’Mahony, A. M., Garvey, J. F., & McNicholas, W. T. (2020) · Journal of Thoracic Disease · doi:10.21037/jtd-sleep-2020-003 · Cited by 45
“Simple indices fail to capture all of the important and potentially diagnostic pathophysiological characteristics (36) and novel strategies for analysis of oximetry have concentrated on the use of automation (38-40) to maximise the diagnostic potential of these data.”
Background
Metadata
- Authors
- Mendonca, F., Mostafa, S. S., Ravelo-Garcia, A. G., Morgado-Dias, F., & Penzel, T.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2019-03
- Volume
- 23
- Issue
- 2
- Pages
- 825-837
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2796062758
- Cited by
- 216
- References
- 92
- FWCI
- 9.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.