A Mode-Adaptive Power-Angle Control Method for Transient Stability Enhancement of Virtual Synchronous Generators
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The virtual synchronous generator (VSG) is emerging as an attractive solution for interconnecting converter-based resources with the power grid. However, due to the nonlinear power-angle relationship, VSGs are, similar to synchronous generators, prone to the loss of synchronization (LOS) under large grid disturbances. This article, thus, analyzes the large-signal synchronization stability, i.e., the transient stability of grid-connected VSGs, and then proposes a mode-adaptive power-angle control method for enhancing the transient stability. In this approach, the positive-feedback mode of the power-angle control of the VSG is detected and adaptively switched to the negative-feedback mode after large disturbances. Thus, the LOS of the VSG can be avoided when there are equilibrium points after the disturbance. Moreover, during severe grid faults without any equilibrium points, a bounded dynamic response of the power angle can be obtained with the mode-adaptive control, and the VSG can still be stabilized even if the fault-clearing time is beyond the critical clearing time. These superior features prevent the VSG-based system from collapsing due to the delayed fault clearance or the malfunction of protective relays. Finally, the time-domain simulations and experimental tests are performed to verify the effectiveness of the control method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Slotine, J.-J. E., & Li, W. (1991) · CERN Document Server (European Organization for Nuclear Research) · Cited by 18,975
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220 · cited 1×
“Unlike synchronous generators (SGs), the dynamics of power converters are highly dependent on their digital control algorithms that feature multiple timescales, programmable, and highly nonlinear [1].”
BackgroundSynchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107 · cited 1×
“2976791 The virtual SG (VSG) control, among other alternative control schemes, is emerging as an attractive approach for reliably operating converter-based power systems [3], [4].”
BackgroundPower-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317 · cited 7×
“No equilibrium points, triggering the current limit Switch to the current limit control [6], and the transient stability is determined by the current limit and the PLL [13]-[18].”
BackgroundMethodInfluentialHarmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis
Wang, X., & Blaabjerg, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2812712 · Cited by 1,282 · cited 2×
“Thus, there have been continuous research efforts on developing control methods for grid-connected converters in order to improve the interoperability and stability of converter-based power systems [2].”
BackgroundSelf-citationLi, Y. W., & Kao, C.-N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022828 · Cited by 1,127
Beck, H.-P., & Hesse, R. (2007) · 2007 9th International Conference on Electrical Power Quality and Utilisation · doi:10.1109/epqu.2007.4424220 · Cited by 1,097 · cited 1×
“2976791 The virtual SG (VSG) control, among other alternative control schemes, is emerging as an attractive approach for reliably operating converter-based power systems [3], [4].”
BackgroundPower System Stabilization Using Virtual Synchronous Generator With Alternating Moment of Inertia
Alipoor, J., Miura, Y., & Ise, T. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2362530 · Cited by 1,039 · cited 4×
“While these advanced VSG schemes can improve the transient stability of the system compared with the conventional method, the positive-feedback nature of the power-angle control of the VSG after the UEP is not changed in [9] and [23]–[26].”
BackgroundMethodResultInfluentialSmall-Signal Modeling and Parameters Design for Virtual Synchronous Generators
Wu, H., Ruan, X., Yang, D., Chen, X., Zhao, W., Lv, Z., & Zhong, Q. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2543181 · Cited by 799 · cited 5×
“Differing from the conventional VSG control that merely replicates the dynamics of the SG [7], the additional damping correction loop is introduced in [9], which provides another degree of freedom for adjusting the system damping ratio without affecting its steady-state frequency droop characteristic.”
BackgroundMethodResultInfluentialSelf-citationOn the Inertia of Future More-Electronics Power Systems
Fang, J., Li, H., Tang, Y. K., & Blaabjerg, F. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2877766 · Cited by 746 · cited 2×
“A prominent feature of the VSG control scheme lies in emulating the power-angle dynamic of SGs, and thus converters can actively reduce the rate of change of frequency (RoCoF) and the frequency nadir of the system [5].”
BackgroundDong, D., Wen, B., Boroyevich, D., Mattavelli, P., & Xue, Y. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334665 · Cited by 709
Transient Stability of Voltage-Source Converters With Grid-Forming Control: A Design-Oriented Study
Pan, D., Wang, X., Liu, F., & Shi, R. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2946310 · Cited by 681 · cited 1×
“When the solid fault occurs near the point of common coupling (PCC), the VSG is generally switched to the vector current control for limiting the current, where the grid synchronization is realized by the backup phase-locked loop (PLL) [6], [11]-[12].”
BackgroundSelf-citationPassivity-Based Stability Assessment of Grid-Connected VSCs—An Overview
Harnefors, L., Wang, X., Yepes, A. G., & Blaabjerg, F. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2490549 · Cited by 674 · cited 2×
“Yet, the total delay time is usually around hundreds of microseconds [2], which is much less than the response time of power loops (usually longer than 100 ms [28]) that determine the transient stability of the VSG.”
BackgroundSelf-citationHuang, L., Xin, H., Wang, Z., Zhang, L., Wu, K., & Hu, J. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2749259 · Cited by 602 · cited 3×
“The transient stability impacts of the current limit control and the PLL have been discussed in [13]–[18].”
BackgroundTransient Angle Stability of Virtual Synchronous Generators Using Lyapunov’s Direct Method
Shuai, Z., Shen, C., Liu, X., Li, Z., & Shen, Z. J. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2866122 · Cited by 546 · cited 6×
“Consequently, the risk of LOS persists whenever the VSG crosses over the UEP after the disturbance [10].”
BackgroundInfluentialFang, J., Tang, Y. K., Li, H., & Li, X. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2759256 · Cited by 463
Design-Oriented Transient Stability Analysis of PLL-Synchronized Voltage-Source Converters
Wu, H., & Wang, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2937942 · Cited by 454
Self-citationTaul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2892142 · Cited by 415 · cited 3×
“This assumption has been justified in recent studies on the transient stability of grid-connected converters [11]–[18] and will be further proved by the simulations and experimental tests in this article.”
BackgroundResultSelf-citationGöksu, Ö., Teodorescu, R., Bak, C. L., Iov, F., & Kjær, P. C. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2295261 · Cited by 380
Wu, H., & Wang, X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2875669 · Cited by 320
Self-citationAdjusting Synchronverter Dynamic Response Speed via Damping Correction Loop
Dong, S., & Chen, Y. C. (2017) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2016.2645450 · Cited by 234 · cited 4×
“While these advanced VSG schemes can improve the transient stability of the system compared with the conventional method, the positive-feedback nature of the power-angle control of the VSG after the UEP is not changed in [9] and [23]–[26].”
BackgroundResultInfluential
Cited by
Grid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Self-citationGrid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Zhang, H., Xiang, W., Lin, W., & Wen, J. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2021.000257 · Cited by 529
Chen, M., Zhou, D., & Blaabjerg, F. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3114723 · Cited by 236
“1) As a typical way to simplify the analysis, the dynamics of the internal voltage and current loops are neglected due to their quick response [15], [22], [26].”
BackgroundMethodInfluentialXiong, X., Wu, C., Hu, B., Pan, D., & Blaabjerg, F. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3046462 · Cited by 202
“been validated in previous research works [8], [15]–[18], [24], [25], thus, it will be further used without extra verification in this article.”
BackgroundMethodInfluential
Metadata
- Authors
- Wu, H., & Wang, X.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2020-06
- Volume
- 8
- Issue
- 2
- Pages
- 1034-1049
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W3006708919
- Cited by
- 227
- References
- 22
- FWCI
- 12.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.