Incipient Interturn Short-Circuit Fault Diagnosis of Permanent Magnet Synchronous Motors Based on the Data-Driven Digital Twin Model
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
As the most common fault of permanent magnet synchronous motor (PMSM), interturn short-circuit fault (ISCF) has great harm and develops rapidly. Once it is not diagnosed in time, it will bring secondary damage to the motor system. In the process of early fault diagnosis, the harmonic of the motor often increases the difficulty of fault feature extraction. In order to improve the reliability of the system, a method for early interturn short-circuit diagnosis of PMSMs based on data-driven digital twin models is proposed in this article. First, the three-phase current residuals of the PMSM under ISCF are analyzed theoretically. Second, the digital twin model of the target motor in healthy states is established through nonlinear auto-regressive model with exogenous inputs (NARX) network. Finally, the early short-circuit diagnosis is completed through the analysis of the three-phase current residual. The method proposed in this article does not need fault data and can complete the diagnosis of minor faults under the condition of large harmonic and certain inherent asymmetry. It has high sensitivity and obvious fault characteristics. Theoretical derivation and experiments verify the effectiveness of the proposed method.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
DCNN-Based Multi-Signal Induction Motor Fault Diagnosis
Shao, S., Yan, R., Lu, Y., Wang, P., & Gao, R. X. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2925247 · Cited by 442 · cited 2×
“[19] constructed a fault diagnostic model of induction motor based on a deep convolution neural network and correctly detected different types of induction motor faults utilizing multivariate data.”
MethodA Motor Current Signal-Based Bearing Fault Diagnosis Using Deep Learning and Information Fusion
Hoang, D. T., & Kang, H. J. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2933119 · Cited by 378 · cited 1×
“approaches [17], [18], [19], [20], [21], [22], [23], [24],”
Sensor Fault Classification Based on Support Vector Machine and Statistical Time-Domain Features
Jan, S. U., Lee, Y.-D., Shin, J., & Koo, I. (2017) · IEEE Access · doi:10.1109/access.2017.2705644 · Cited by 291 · cited 2×
“approaches [17], [18], [19], [20], [21], [22], [23], [24],”
MethodAnalysis of Permanent Magnet Synchronous Motor Fault Diagnosis Based on Learning
Kao, I.-H., Wang, W.-J., Lai, Y.-H., & Perng, J.-W. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2847800 · Cited by 221 · cited 2×
“[17] employed a 1-D convolutional neural network (CNN) to diagnose bearing and demagnetization faults.”
MethodHang, J., Zhang, J., Cheng, M., & Huang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2388493 · Cited by 218 · cited 1×
“when a motor ISCF occurs, the zero sequence components [5]”
BackgroundRosero, J. A., Romeral, L., Ortega, J. A., & Rosero, E. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011580 · Cited by 214 · cited 1×
“transform [3], Wigner distribution [4], and so on.”
BackgroundA Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM
Mazzoletti, M. A., Bossio, G. R., De Angelo, C. H., & Espinoza-Trejo, D. R. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2688973 · Cited by 214 · cited 2×
“in PMSMs based on residual current [12], [13], [14].”
BackgroundMethodKim, K.-H. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2060463 · Cited by 184 · cited 1×
“dq-axis currents or reference voltages [7], [8].”
Lee, H., Jeong, H., Koo, G., Ban, J., & Kim, S. W. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2978690 · Cited by 151 · cited 2×
“[18] accomplished the early fault identification and severity analysis of PMSM stator winding by analyzing positive and negative sequence current and speed data with a recurrent neural network (RNN).”
BackgroundWang, B., Wang, J., Griffo, A., & Sen, B. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2793188 · Cited by 150 · cited 1×
“Some researchers use the second harmonic in variables, such as speed, instantaneous power, and cost function [9], [10], under model predictive control to achieve interturn shortcircuit detection.”
MethodAn Early Stage Interturn Fault Diagnosis of PMSMs by Using Negative-Sequence Components
Jeong, H., Moon, S., & Kim, S. W. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2677355 · Cited by 141 · cited 2×
“[6] studied the relationship between short-circuit current and speed and produced a new fault index by incorporating a negative sequence voltage component to make it speed-insensitive.”
BackgroundAubert, B., Regnier, J., Caux, S., & Alejo, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2348934 · Cited by 137
Moon, S., Jeong, H., Lee, H., & Kim, S. W. (2018) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2017.2726142 · Cited by 123 · cited 1×
“in PMSMs based on residual current [12], [13], [14].”
BackgroundCurrent-Residual-Based Stator Interturn Fault Detection in Permanent Magnet Machines
Hu, R., Wang, J., Mills, A. R., Chong, E., & Sun, Z. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2965500 · Cited by 120
Skowron, M., Orłowska-Kowalska, T., & Kowalski, C. T. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3146557 · Cited by 113 · cited 1×
“approaches [17], [18], [19], [20], [21], [22], [23], [24],”
On Bayesian Optimization-Based Residual CNN for Estimation of Inter-Turn Short Circuit Fault in PMSM
Song, Q., Wang, M., Lai, W., & Zhao, S. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3207181 · Cited by 106 · cited 2×
“approaches [17], [18], [19], [20], [21], [22], [23], [24],”
MethodDu, B., Wu, S., Han, S., & Cui, S. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2496900 · Cited by 105 · cited 1×
“dq-axis currents or reference voltages [7], [8].”
Husari, F., & Seshadrinath, J. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2021.3067321 · Cited by 101 · cited 1×
“In addition, various machine learning approaches, such as support vector machine [24], [25], [26], [27], decision tree [27], and Bayesian network, are utilized for motor defect diagnostics.”
MethodIncipient Fault Detection in Stator Windings of an Induction Motor Using Stockwell Transform and SVM
Singh, M., & Shaik, A. G. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3002444 · Cited by 96
Ehya, H., Skreien, T. N., & Nysveen, A. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2021.3054674 · Cited by 92 · cited 1×
“In addition, various machine learning approaches, such as support vector machine [24], [25], [26], [27], decision tree [27], and Bayesian network, are utilized for motor defect diagnostics.”
MethodHigh-Frequency Voltage Injection Based Stator Interturn Fault Detection in Permanent Magnet Machines
Hu, R., Wang, J., Mills, A. R., Chong, E., & Sun, Z. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3005757 · Cited by 86 · cited 2×
“To prevent the misdiagnosis caused by similar winding failures such as ISCF and the high resistance connection fault, highfrequency voltage injection-based methods are proposed [28].”
MethodWang, C., Liu, X., & Chen, Z. (2014) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2014.2318207 · Cited by 78 · cited 1×
“transform [3], Wigner distribution [4], and so on.”
BackgroundSelf-citationHusari, F. M., & Seshadrinath, J. (2021) · IEEE Transactions on Artificial Intelligence · doi:10.1109/tai.2021.3135799 · Cited by 69 · cited 2×
“approaches [17], [18], [19], [20], [21], [22], [23], [24],”
MethodOn the short-circuiting Fault Detection in a PMSM by means of Stator Current Transformations
Rosero, J. A., Romeral, L., Cusido, J., Garcia, A., & Ortega, J. A. (2007) · 2007 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2007.4342300 · Cited by 63 · cited 2×
“Fourier transform [1], wavelet transform [2], Hilbert Huang”
BackgroundMethodInter-Turn Fault Detection in Stator Winding of PMSM Using Wavelet Transform
Moosavi, S. S., Esmaili, Q., Djerdir, A., & Amirat, Y. A. (2017) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2017.8330891 · Cited by 27 · cited 2×
“Fourier transform [1], wavelet transform [2], Hilbert Huang”
BackgroundMethodAlam, M., & Payami, S. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3169709 · Cited by 26
Xu, Y., Wang, Y., & Zou, J. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3125653 · Cited by 25 · cited 1×
“[15] can realize ISCF diagnosis by analyzing the second and eighth harmonics of”
MethodPalavicino, P. C., Lee, W., & Sarlioglu, B. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3203032 · Cited by 8 · cited 1×
“[16] use a current observer to detect ISCF, and compensation has been made to minimize the short-circuit current by injecting d-axis current.”
Method
Research works printed but not linked: 1
- ding, 2019, Inter-turn fault diagnosis of permanent magnet synchronous machine considering model predictive control, Proc CSEE, 39, 3697
Cited by
An Overview of Digital Twin Technology for Power Electronics: State-of-the-Art and Future Trends
Wu, C., Cui, Z., Xia, Q., Yue, J., & Lyu, F. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3570638 · Cited by 60
Digital Twin Modeling Method of Three-Phase Inverter-Driven PMSM Systems for Parameter Estimation
Song, W., Zou, Y., Ma, C., & Zhang, S. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3330240 · Cited by 59
“[36], [37], and [38] show the digital twin model of PMSMs, however the entire closed-loop system, such as the control system and the inverter, is not involved.”
BackgroundRanawaka, A. S. R. A., Alahakoon, D., Sun, Y., & Hewapathirana, K. (2024) · Energies · doi:10.3390/en17215342 · Cited by 66
Research and Prospects of Digital Twin-Based Fault Diagnosis of Electric Machines
Hu, J. S., Han, X., Ye, Z., Luo, N., & Zhou, M. (2025) · Sensors · doi:10.3390/s25082625 · Cited by 52
“Reference [96] proposed a permanent magnet synchronous motor fault diagnosis method for a coal mine belt conveyor based on a digital twin and an improved sparrow search algorithm-optimized random forest (ISSA-RF) method, realizing interactive data transmission between the physical entity and the…”
Fault Detection of Permanent Magnet Synchronous Machines: An Overview
Li, H., Zhu, Z. Q., Azar, Z., Clark, R., & Wu, Z. (2025) · Energies · doi:10.3390/en18030534 · Cited by 42
“To better account for parameter uncertainty and nonlinearity, digital twin models are used to obtain the current residuals [96].”
Metadata
- Authors
- Chen, Z., Liang, D., Jia, S., Yang, L., & Yang, S.
- Affiliations
- State Key Laboratory of Electrical Insulation and Power Equipment (CN)
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2023-06
- Volume
- 11
- Issue
- 3
- Pages
- 3514-3524
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W4324116351
- Cited by
- 72
- References
- 28
- Citations by year
- 2026: 10 · 2025: 36 · 2024: 19 · 2023: 7
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Journal of Emerging and Selected Topics in Power Electronics (publishedVersion)
- Funders
- National Natural Science Foundation of China (51737010)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- inter-turn short-circuit fault, permanent magnet synchronous motor, early fault diagnosis, digital twin, NARX network, data-driven modeling, harmonic distortion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.