The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Creating, transporting, cutting, and merging liquid droplets by electrowetting-based actuation for digital microfluidic circuits
Abstract
Reports the completion of four fundamental fluidic operations considered essential to build digital microfluidic circuits, which can be used for lab-on-a-chip or micro total analysis system (μTAS): 1) creating, 2) transporting, 3) cutting, and 4) merging liquid droplets, all by electrowetting, i.e., controlling the wetting property of the surface through electric potential. The surface used in this report is, more specifically, an electrode covered with dielectrics, hence, called electrowetting-on-dielectric (EWOD). All the fluidic movement is confined between two plates, which we call parallel-plate channel, rather than through closed channels or on open surfaces. While transporting and merging droplets are easily verified, we discover that there exists a design criterion for a given set of materials beyond which the droplet simply cannot be cut by EWOD mechanism. The condition for successful cutting is theoretically analyzed by examining the channel gap, the droplet size and the degree of contact angle change by electrowetting on dielectric (EWOD). A series of experiments is run and verifies the criterion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrodynamic and Hydromagnetic Stability
Chandrasekhar, S., & Gillis, J. (1962) · Physics Today · doi:10.1063/1.3058072 · Cited by 10,329
Hydrodynamic and hydromagnetic stability
Chandrasekhar, S. (1961) · CERN Document Server (European Organization for Nuclear Research) · Cited by 6,730
Fundamentals of Microfabrication
(2016) · Micromechatronics · doi:10.1201/b15830-17 · Cited by 2,109
Electrowetting-based actuation of liquid droplets for microfluidic applications
Pollack, M. G., Fair, R. B., & Shenderov, A. D. (2000) · Applied Physics Letters · doi:10.1063/1.1308534 · Cited by 1,481
Micromachined Transducers Sourcebook
Kovacs, G. T. A. (1998) · Cited by 1,200
Electrowetting and electrowetting-on-dielectric for microscale liquid handling
Lee, J., Moon, H., Fowler, J., Schoellhammer, T., & Kim, C.-J. (2002) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00734-8 · Cited by 652
Self-citationReversible Electrowetting and Trapping of Charge: Model and Experiments
Verheijen, H. J. J., & Prins, M. W. J. (1999) · Langmuir · doi:10.1021/la990548n · Cited by 509
The Science of Soap Films and Soap Bubbles
Isenberg, C. (1978) · CERN Document Server (European Organization for Nuclear Research) · Cited by 390
Surface-tension-driven microactuation based on continuous electrowetting
Lee, J., & Kim, C.-J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846697 · Cited by 390
Self-citationThermocapillary pumping of discrete drops in microfabricated analysis devices
Sammarco, T. S., & Burns, M. A. (1999) · AIChE Journal · doi:10.1002/aic.690450215 · Cited by 282
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Electrowetting: from basics to applications
Mugele, F., & Baret, J.-C. (2005) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/17/28/r01 · Cited by 2,092
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Dynamics and stability of thin liquid films
Craster, R. V., & Matar, O. K. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.1131 · Cited by 1,441
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Srinivasan, V., Pamula, V. K., & Fair, R. B. (2004) · Lab on a Chip · doi:10.1039/b403341h · Cited by 1,066
Digital microfluidics: is a true lab-on-a-chip possible?
Fair, R. B. (2007) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0161-8 · Cited by 1,063
Hydrophilic and superhydrophilic surfaces and materials
Drelich, J., Chibowski, E., Meng, D. D., & Terpilowski, K. (2011) · Soft Matter · doi:10.1039/c1sm05849e · Cited by 911
Choi, K., Ng, A. H. C., Fobel, R., & Wheeler, A. R. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143028 · Cited by 817
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Fu, Y. Q., Luo, J. K., Nguyen, N. T., Walton, A. J., Flewitt, A. J., Zu, X. T., Li, Y., McHale, G., Matthews, A., Iborra, E., et al. (2017) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.04.006 · Cited by 646
Development of a digital microfluidic platform for point of care testing
Sista, R., Hua, Z., Thwar, P., Sudarsan, A., Srinivasan, V., Eckhardt, A., Pollack, M., & Pamula, V. (2008) · Lab on a Chip · doi:10.1039/b814922d · Cited by 550
Rapid droplet mixers for digital microfluidic systems
Paik, P., Pamula, V. K., & Fair, R. B. (2003) · Lab Chip · doi:10.1039/b307628h · Cited by 497
Revisiting lab-on-a-chip technology for drug discovery
Neužil, P., Giselbrecht, S., Länge, K., Huang, T. J., & Manz, A. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3799 · Cited by 487
PRINCIPLES OF MICROFLUIDIC ACTUATION BY MODULATION OF SURFACE STRESSES
Darhuber, A. A., & Troian, S. M. (2005) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122052 · Cited by 484
A review of digital microfluidics as portable platforms for lab-on a-chip applications
Samiei, E., Tabrizian, M., & Hoorfar, M. (2016) · Lab on a Chip · doi:10.1039/c6lc00387g · Cited by 471
Liquid metal enabled microfluidics
Khoshmanesh, K., Tang, S.-Y., Zhu, J. Y., Schaefer, S., Mitchell, A., Kalantar-zadeh, K., & Dickey, M. D. (2017) · Lab on a Chip · doi:10.1039/c7lc00046d · Cited by 458
Droplet Actuation by Electrowetting-on-Dielectric (EWOD): A Review
Nelson, W. C., & Kim, C.-J. ‘. (2012) · Journal of Adhesion Science and Technology · doi:10.1163/156856111x599562 · Cited by 454
Self-citationNanotribology and nanomechanics of MEMS/NEMS and BioMEMS/BioNEMS materials and devices
Bhushan, B. (2007) · Microelectronic Engineering · doi:10.1016/j.mee.2006.10.059 · Cited by 413
The Digital Revolution: A New Paradigm for Microfluidics
Abdelgawad, M., & Wheeler, A. R. (2009) · Advanced Materials · doi:10.1002/adma.200802244 · Cited by 382
Some thoughts on superhydrophobic wetting
Dorrer, C., & Rühe, J. (2009) · Soft Matter · doi:10.1039/b811945g · Cited by 375
Magnetic digital microfluidics – a review
Zhang, Y., & Nguyen, N.-T. (2017) · Lab on a Chip · doi:10.1039/c7lc00025a · Cited by 364
On-chip micromanipulation and assembly of colloidal particles by electric fields
Velev, O. D., & Bhatt, K. H. (2006) · Soft Matter · doi:10.1039/b605052b · Cited by 361
Microfluidics for medical diagnostics and biosensors
Rivet, C., Lee, H., Hirsch, A., Hamilton, S., & Lu, H. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.015 · Cited by 356
On-chip manipulation of free droplets
Velev, O. D., Prevo, B. G., & Bhatt, K. H. (2003) · Nature · doi:10.1038/426515a · Cited by 354
Planar chip device for PCR and hybridization with surface acoustic wave pump
Guttenberg, Z., Müller, H., Habermüller, H., Geisbauer, A., Pipper, J., Felbel, J., Kielpinski, M., Scriba, J., & Wixforth, A. (2005) · Lab Chip · doi:10.1039/b412712a · Cited by 349
Acoustophoretic contactless transport and handling of matter in air
Foresti, D., Nabavi, M., Klingauf, M., Ferrari, A., & Poulikakos, D. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1301860110 · Cited by 340
Microvalves and Micropumps for BioMEMS
Au, A. K., Lai, H., Utela, B. R., & Folch, A. (2011) · Micromachines · doi:10.3390/mi2020179 · Cited by 332
Chemical and Biological Applications of Digital-Microfluidic Devices
Fair, R. B., Khlystov, A., Tailor, T. D., Ivanov, V., Evans, R. D., Srinivasan, V., Pamula, V. K., Pollack, M. G., Griffin, P. B., & Zhou, J. (2007) · IEEE Design & Test of Computers · doi:10.1109/mdt.2007.8 · Cited by 325
Digital microfluidics: a versatile tool for applications in chemistry, biology and medicine
Jebrail, M. J., Bartsch, M. S., & Patel, K. D. (2012) · Lab on a Chip · doi:10.1039/c2lc40318h · Cited by 324
Integrated polymerase chain reaction chips utilizing digital microfluidics
Chang, Y.-H., Lee, G.-B., Huang, F.-C., Chen, Y.-Y., & Lin, J.-L. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-8171-y · Cited by 324
Wettability Switching Techniques on Superhydrophobic Surfaces
Verplanck, N., Coffinier, Y., Thomy, V., & Boukherroub, R. (2007) · Nanoscale Research Letters · doi:10.1007/s11671-007-9102-4 · Cited by 310
Scaling law in liquid drop coalescence driven by surface tension
Wu, M., Cubaud, T., & Ho, C.-M. (2004) · Physics of Fluids · doi:10.1063/1.1756928 · Cited by 299
Moon, H., Wheeler, A. R., Garrell, R. L., Loo, J. A., & Kim, C.-J. ?. (2006) · Lab on a Chip · doi:10.1039/b601954d · Cited by 296
Self-citationHeterogeneous immunoassays using magnetic beads on a digital microfluidic platform
Sista, R. S., Eckhardt, A. E., Srinivasan, V., Pollack, M. G., Palanki, S., & Pamula, V. K. (2008) · Lab on a Chip · doi:10.1039/b807855f · Cited by 294
Pneumatic and hydraulic microactuators: a review
De Volder, M., & Reynaerts, D. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/4/043001 · Cited by 278
Dispensing nano–pico droplets and liquid patterning by pyroelectrodynamic shooting
Ferraro, P., Coppola, S., Grilli, S., Paturzo, M., & Vespini, V. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.82 · Cited by 271
López-Herrera, J. M., Popinet, S., & Herrada, M. A. (2011) · Journal of Computational Physics · doi:10.1016/j.jcp.2010.11.042 · Cited by 265
Review of MEMS-based drug delivery and dosing systems
Tsai, N.-C., & Sue, C.-Y. (2007) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2006.06.014 · Cited by 258
Gong, J., & Kim, C.-J. “. (2008) · Lab on a Chip · doi:10.1039/b717417a · Cited by 258
Self-citationCurrent commercialization status of electrowetting-on-dielectric (EWOD) digital microfluidics
Li, J., & Kim, C.-J. “. (2020) · Lab on a Chip · doi:10.1039/d0lc00144a · Cited by 257
Self-citationElectrokinetics in Micro Devices for Biotechnology Applications
Wong, P. K., Wang, T.-H., Deval, J. H., & Ho, C.-M. (2004) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2004.828659 · Cited by 254
Development and future of droplet microfluidics
Nan, L., Zhang, H., Weitz, D. A., & Shum, H. C. (2024) · Lab on a Chip · doi:10.1039/d3lc00729d · Cited by 253
Photo-actuation of liquids for light-driven microfluidics: state of the art and perspectives
Baigl, D. (2012) · Lab on a Chip · doi:10.1039/c2lc40596b · Cited by 253
Berthier, E., Warrick, J., Yu, H., & Beebe, D. J. (2008) · Lab on a Chip · doi:10.1039/b717422e · Cited by 114
Choi, K., Kim, J.-Y., Ahn, J.-H., Choi, J.-M., Im, M., & Choi, Y.-K. (2012) · Lab on a Chip · doi:10.1039/c2lc21203j · Cited by 77
(2023) · doi:10.3390/s23218924 · Cited by 13
Metadata
- Authors
- Cho, S. K., Moon, H., & Kim, C.-J.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2003-02
- Volume
- 12
- Issue
- 1
- Pages
- 70-80
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2150068960
- Cited by
- 1,598
- References
- 11
- FWCI
- 46.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.