The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Arrays of hollow out-of-plane microneedles for drug delivery
Abstract
Drug delivery based on MEMS technology requires an invasive interface such as microneedles, which connects the microsystem with the biological environment. Two-dimensional arrays of rigid hollow microneedles have been fabricated from single-crystal silicon using a combination of deep reactive ion etching and isotropic etching techniques. The fabricated needles are typically 200 /spl mu/m long with a wide base and a channel diameter of 40 /spl mu/m. The fabrication process allows creating either blunt needles or needles with sharp tips. Their shape and size make these needles extremely suitable for minimally invasive painless epidermal drug delivery. MEMS technology allows for batch fabrication and integration with complex microsystems. Fluid has been successfully injected 100 /spl mu/m deep into sample tissue through arrays of microneedles. Needle breakage did not occur during this procedure. Experiments have shown that the modified Bernoulli equation is a good model for liquid flowing through the narrow microneedle lumen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Silicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413
Quantification of myelinated endings and mechanoreceptors in human digital skin
Nolano, M., Provitera, V., Crisci, C., Stancanelli, A., Wendelschafer‐Crabb, G., Kennedy, W. R., & Santoro, L. (2003) · Annals of Neurology · doi:10.1002/ana.10615 · Cited by 201
Cited by
Larrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
Microneedle-based drug delivery systems: Microfabrication, drug delivery, and safety
Donnelly, R. F., Singh, T. R. R., & Woolfson, A. D. (2010) · Drug Delivery · doi:10.3109/10717541003667798 · Cited by 708
Honda, W., Harada, S., Arie, T., Akita, S., & Takei, K. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303874 · Cited by 456
Donnelly, R. F., Majithiya, R., Singh, T. R. R., Morrow, D. I. J., Garland, M. J., Demir, Y. K., Migalska, K., Ryan, E., Gillen, D., Scott, C. J., et al. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0169-8 · Cited by 417
Hydrogel‐Forming Microneedles: Current Advancements and Future Trends
Turner, J. G., White, L. R., Estrela, P., & Leese, H. S. (2021) · Macromolecular Bioscience · doi:10.1002/mabi.202000307 · Cited by 413
Metadata
- Authors
- Stoeber, B., & Liepmann, D.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2005-06
- Volume
- 14
- Issue
- 3
- Pages
- 472-479
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2171506711
- Cited by
- 178
- References
- 5
- FWCI
- 8.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Arrays of hollow out-of-plane microneedles for drug delivery. https://app.cochat.ai/papers/10.1109/jmems.2005.844843
- The paper
- Stoeber, B., & Liepmann, D. (2005). Arrays of hollow out-of-plane microneedles for drug delivery. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2005.844843
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.